SIPLUS SIWAREX U electronic weighing system |
Integration in automation systems: | |
S7-300 | direct integration |
S7-400 (H) | via ET 200M |
PCS 7 (H) | via ET 200M |
C7 | via IM or ET 200M |
Automation systems from other manufacturers | via ET 200M |
Stand-alone (without SIMATIC CPU) | possible with IM 153-1 |
Communication interfaces | - SIMATIC S7 (I/O bus)
- RS 232
- TTY
|
Connection of remote indicator (via serial TTY interface) | Total Channel 1, 2 or preset value 1, 2 |
Adjustment of weighing system | via SIMATIC (I/O bus) or PC with SIWATOOL U (RS 232) |
Measurement properties | |
Error limit according to DIN 1319-1 of full-scale value at 20 °C ± 10 K | 0,05 % |
Internal ADC resolution Data format of weight values | 65535 2 bytes (fixed point) |
Number of measurements/second | 50 |
Digital filter | 0.05 to 5 Hz (in 7 steps), mean value filter |
Weighing system functions | |
Weight values | Total |
Limit values | 2 (min./max.) |
Zero setting function | per command |
Load cells | DMS in 4-wire or 6-wire system |
Load cell supply | |
Infeed voltage Us (rated value) | 6 V DC1) |
Max. supply current | ≤ 150 mA per channel |
Permissible load resistance | |
| > 40 О© per channel |
| < 4010 О© |
| | with Ex(i) interface: |
| > 87 О© per channel |
| < 4010 О© |
Permissible load cell characteristic value | up to 4 mV/V |
Max. distance for load cells | 500 m1) 150/500 m for Gas Group IIC 500 m1) for Gas Group IIB (see Equipment Manual SIWAREX IS) |
Intrinsically safe weighing system infeed | optional (Ex interface) with SIWAREX IS |
Power supply | |
Rated voltage | 24 VDC |
Max. current consumption | 150 mA (single-channel) / 240 mA (two-channel) |
Current consumption on backplane bus | ≤ 100 mA |
Certification | ATEX 95, FM, cULUS Haz. Loc. |
IP degree of protection to DIN EN 60529; IEC 60529 | IP20 |
Climatic requirements | |
Tmin (IND) to Tmax (IND) (operating temperature) | |
| 0 ... +60 °C |
| 0 ... +40 °C |
EMC requirements to | NAMUR NE21, Part 1 EN 61326 |
Dimensions | 40 x 125 x 130 mm |