Article number

6AG1321-1BH02-2AA0

6AG1321-1BL00-2AA0

6AG1321-1CH20-2AA0

6AG1321-1FF01-2AA0

6AG1321-1FF10-7AA0

SIPLUS SM321 16DE/24VDC

SIPLUS SM321 32DE/24VDC

SIPLUS SM 321 16DE/ DC 48-125 V

SIPLUS S7-300 SM321 8DE/120/230VAC

SIPLUS S7-300 SM321 8DI/120/230VAC

Supply voltage

Load voltage L+

  • Rated value (DC)

24V

24V

48V

  • permissible range, lower limit (DC)

20.4V

20.4V

48V

  • permissible range, upper limit (DC)

28.8V

28.8V

125V

Load voltage L1

  • Rated value (AC)

230V; 120/230 V AC

230V; 120/230 V AC; all load voltages must have the same phase.

Input current

from backplane bus 5 V DC, max.

10mA

15mA

40mA

29mA

100mA

Power loss

Power loss, typ.

3.5W

6.5W

4.3W

4.9W

4.9W

Digital inputs

Number of digital inputs

16

32

16

8

8

Input characteristic curve in accordance with IEC 61131, type 1

Yes

Yes

Yes

Yes

Yes

Number of simultaneously controllable inputs

all mounting positions

  • up to 60 C, max.

8; 6 @ Ue 146 V

  • up to 70 C, max.

6; 4 @ Ue 146 V

horizontal installation

  • up to 40 C, max.

16

32

  • up to 50 C, max.

8

  • up to 60 C, max.

16; 16 @ > 60 C

16; 12 @ > 60 C

8; 6 to Ue 146 V

8; up to 70 C

8; 8 @ > 60 C

vertical installation

  • up to 40 C, max.

16

8

Input voltage

  • Type of input voltage

DC

DC

DC

AC

AC

  • Rated value (DC)

24V

24V

48V; 48 V DC to 125 V DC

  • Rated value (AC)

230V; 120/230 V AC (47 ... 63 Hz)

120V; 120/230 V AC (47 ... 63 Hz)

  • for signal "0"

-30 to +5V

-30 to +5V

-146 V DC to +15 V DC

0 to 40V

0 to 40V

  • for signal "1"

13 to 30V

13 to 30V

30 V DC to 146 V DC

79 to 264V

79 to 264V

Input current

  • for signal "1", typ.

7mA

7mA

3.5mA

6.5mA; (120 V); 11 mA (230 V)

7.5mA; (120 V); 17.3 mA (230 V)

Input delay (for rated value of input voltage)

for standard inputs

  • parameterizable

No

No

No

No

No

  • at "0" to "1", min.

1.2ms

1.2ms

0.1ms

  • at "0" to "1", max.

4.8ms

4.8ms

3.5ms

25ms

25ms

  • at "1" to "0", min.

1.2ms

1.2ms

0.7ms

  • at "1" to "0", max.

4.8ms

4.8ms

3ms

25ms

25ms

Cable length

  • shielded, max.

1000m

1000m

1000m

1000m

1000m

  • unshielded, max.

600m

600m

600m

600m

600m

Encoder

Connectable encoders

  • 2-wire sensor

Yes

Yes

Yes

Yes

Yes

  • permissible quiescent current (2-wire sensor), max.

1.5mA

1.5mA

1mA

2mA

2mA

Isochronous mode

Isochronous operation (application synchronized up to terminal)

No

No

No

No

No

Interrupts/diagnostics/status information

Diagnostic functions

No

No

No

No

No

Alarms

  • Diagnostic alarm

No

No

No

No

No

  • Hardware interrupt

No

No

No

No

No

Diagnostics indication LED

  • Group error SF (red)

No

No

No

  • Status indicator digital input (green)

Yes

Yes

Yes

Yes

Yes

Potential separation

Potential separation digital inputs

  • between the channels

No

No

No

No

Yes

  • between the channels, in groups of

16

16

8

2

1

  • between the channels and backplane bus

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Permissible potential difference

between different circuits

75 V DC/60 V AC

75 V DC/60 V AC

146 V DC/132 V AC

Isolation

Isolation tested with

500 V DC

500 V DC

1500 V DC

4 000 V DC

1500 V AC

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

Yes

Yes

UL approval

Yes; File E239877

Yes; File E239877

Yes; File E239877

Yes; File E239877

Yes; File E239877

FM approval

Yes; CofC 3028431

Yes; CofC 3028431

No

No

Yes; CofC 3028431

RCM (formerly C-TICK)

Yes

Yes

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Yes

Yes

Railway application

  • EN 50155

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Use in hazardous areas

  • ATEX

Yes

Yes

No

No

No

Ambient conditions

Ambient temperature during operation

  • min.

-40C; = Tmin

-40C; = Tmin

-25C

-40C; = Tmin

-25C

  • max.

70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use

70C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/ULhaz/ATEX/FM use applies

70C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/ULhaz/ATEX/FM use applies

70C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/ULhaz/ATEX/FM use applies

70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use

Ambient temperature during storage/transportation

  • min.

-40C

-40C

-40C

-40C

-40C

  • max.

70C

70C

70C

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

Resistance

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Connection method

required front connector

20-pin

40-pin

20-pin

20-pin

40-pin

Dimensions

Width

40mm

40mm

40mm

40mm

40mm

Height

125mm

125mm

125mm

125mm

125mm

Depth

120mm

120mm

120mm

120mm

120mm

Weights

Weight, approx.

200g

260g

200g

240g

240g


Article number

6AG1321-1FH00-7AA0

6AG1321-7BH01-2AB0

6AG1321-7TH00-4AB0

SIPLUS S7-300 SM 321 16DI/120/230VAC

SIPLUS SM321 16DE/24VDC

SIPLUS PCS 7 SM321 16DE

Supply voltage

Load voltage L+

  • Rated value (DC)

24V

24V

  • permissible range, lower limit (DC)

20.4V

  • permissible range, upper limit (DC)

28.8V

Load voltage L1

  • Rated value (AC)

230V; 120/230 V AC; all load voltages must have the same phase.

Input current

from load voltage L+ (without load), max.

90mA

100mA

from backplane bus 5 V DC, max.

29mA

130mA

100mA

Power loss

Power loss, typ.

4.9W

4W

11W

Time stamping

Accuracy

1ms

Digital inputs

Number of digital inputs

16

16

16

Input characteristic curve in accordance with IEC 61131, type 1

Yes

No

Input characteristic curve in accordance with IEC 61131, type 2

Yes

Yes

horizontal installation

  • up to 40 C, max.

16

  • up to 60 C, max.

16; up to 70 C

16

16

vertical installation

  • up to 40 C, max.

16

16

16

Input voltage

  • Type of input voltage

AC

DC

DC

  • Rated value (DC)

24V

8.2V; 8.2V/18V

  • Rated value (AC)

230V; 120/230 V AC (47 ... 63 Hz)

  • for signal "0"

0 to 40V

-30 to +5V

  • for signal "1"

79 to 264V

13 to 30V

Input current

  • for signal "1", typ.

6.5mA; (120V, 60Hz), 16mA (230V, 50Hz)

7mA

10mA; for NAMUR: 2.1 to 7 mA, for 10k ohm/47k ohm contact: typical 10mA, for 4 wire BEROs: typical 10 mA

Input delay (for rated value of input voltage)

for standard inputs

  • parameterizable

No

Yes; 0.1 / 0.5 / 3 / 15 / 20 ms

  • at "0" to "1", min.

25ms

2.5ms

  • at "0" to "1", max.

25ms

3.5ms

  • at "1" to "0", min.

2.5ms

  • at "1" to "0", max.

25ms

3.5ms

Cable length

  • shielded, max.

1000m

1000m

400m; max. 200m with 8.2 V sensor, max. 400m with 18 V sensor

  • unshielded, max.

600m

600m

Not permitted

Encoder

Connectable encoders

  • 2-wire sensor

Yes

Yes

  • permissible quiescent current (2-wire sensor), max.

2mA

2mA

Isochronous mode

Isochronous operation (application synchronized up to terminal)

No

Yes

Interrupts/diagnostics/status information

Diagnostic functions

No

Yes; Parameterizable

Yes

Alarms

  • Diagnostic alarm

No

Yes; Parameterizable

Yes

  • Hardware interrupt

No

Yes; Parameterizable

Yes

Diagnostic messages

  • Wire-break

Yes; to I< 1 mA

Yes

Diagnostics indication LED

  • Group error SF (red)

No

Yes

Yes

  • Status indicator digital input (green)

Yes

Yes

Yes

Potential separation

Potential separation digital inputs

  • between the channels

No

No

Yes

  • between the channels, in groups of

4

16

8

  • between the channels and backplane bus

Yes; Optocoupler

Yes; Optocoupler

Yes

Permissible potential difference

between different circuits

75 V DC/60 V AC

75 V DC/60 V AC

Isolation

Isolation tested with

4 000 V DC

500 V DC

600 V DC

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

UL approval

Yes; File E239877

Yes; File E239877

Yes; File E239877

FM approval

Yes; CofC 3028431

Yes; CofC 3028431

Yes; CofC 3028431

RCM (formerly C-TICK)

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Railway application

  • EN 50155

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Use in hazardous areas

  • ATEX

No

Yes

Yes

Ambient conditions

Ambient temperature during operation

  • min.

-40C; = Tmin

-25C

0C

  • max.

70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use

70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use

60C

  • At cold restart, min.

0C

Ambient temperature during storage/transportation

  • min.

-40C

-40C

-40C

  • max.

70C

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

Resistance

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Connection method

required front connector

20-pin

20-pin

40-pin

Dimensions

Width

40mm

40mm

40mm

Height

125mm

125mm

125mm

Depth

120mm

120mm

120mm

Weights

Weight, approx.

240g

200g


















2018
Siemens Industry Catalog Drive technology Automation technology Automation systems SIMATIC Industrial Automation Systems Controllers I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP SIMATIC ET 200MP SIMATIC ET 200S SIMATIC ET 200M Interface modules SIPLUS Interface modules I/O modules Digital modules SM 321 digital input modules SM 322 digital output modules SM 323/SM 327 digital input/output modules SIPLUS S7-300 digital modules SIPLUS S7-300 SM 321 SIPLUS S7-300 SM 322 SIPLUS S7-300 SM 323 Analog modules Analog modules with HART F digital/analog modules Ex digital modules Ex analog modules Function modules Special modules Communication Connection system Power supplies SIMATIC ET 200iSP SIMATIC ET 200 systems without control cabinet IO systems for heating elements PROFIBUS components PROFINET components Network components for PROFIBUS Network transitions SIMATIC control systems Software for SIMATIC Controllers Programming devices Siemens Partner Programm SIMOTION Motion Control System SINUMERIK CNC automation systems System cabling/control cabinets Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need