During initial commissioning, please note the following:

  • For mechanical installation and configuration, see the "SIDOOR Door Control Systems AT40, ATD400K, ATD400S, ATD400V, ATD400W" manual.http://support.automation.siemens.com/WW/view/en/58531074
  • Electrical configuration and commissioning:
    • Push the door into the "CLOSED" position.
    • Open the device cover.
    • Plug in the motor connector
    • Press and hold the learn run button
    • The learn run starts automatically and the learn run button can be released.
    • On completion of the learn run, the door is in the "CLOSED" position and the 7-segment display indicates "u".
    • The door can now be moved via the "OPEN" and "CLOSE" buttons with the default profile.