19" rack unit- 19" rack unit with 3 height units (HU) for installation
- in hinged frames
- in cabinets
- Gas connections directly on the analyzer module for sample gas inlet and outlet: for pipe diameter 6 mm
- Purging gas connections (optional), purging gas connection for 6 mm or 1/4" hose (optional)
- ATEX-/IECEx approval for Zone 2
Wall-mounted device- Gas connections directly on the analyzer module for sample gas inlet and outlet: Pipe union for pipe diameter 6 mm
- Purging gas connections (optional): Pipe diameter 12 mm
- ATEX-/IECEx approval for Zones 1 and 2
Field device- Field control unit: Flameproof encapsulated enclosure with mounted Ex e connection enclosure (IP55)
- Ex-d field module with installed module (IP65)
- ATEX-/IECEx approval for Zone 1
- Maximum cable length of the cable between field module and field control unit: 7 m
Display and control panel- LCD panel for simultaneous display of:
- Measured value
- Status bar
- Measuring ranges
- Menu-driven operation for parameterization, test functions, adjustment
- Operator support in plain text
- Operating software in six languages (English, German, French, Italian, Spanish, Portuguese)
 Display and operator panel of the SIPROCESS GA700 devices Inputs and outputs- 19" rack unit and wall-mounted unit
- 8 digital inputs, designed for 24 V, floating, freely configurable (e.g. for measurement range switchover, processing of external signals from sample preparation)
- 8 relay outputs, with changeover contacts, freely configurable (e.g. for faults, maintenance requests, limit alarms, external solenoid valves)
- Ethernet connection contained in the basic unit (connection on the rear side, Ethernet RJ 45, 100 MBit)
- Service interface (front side); Ethernet RJ 45, 100 MBit.
- Field control unit
- 1 analog output for each component 0/4 to 20 mA
- 5 relay outputs, with changeover contacts, freely configurable, e.g. for faults or measuring range identification
- 5 digital inputs, designed for 24 V, floating, freely configurable, e.g. for measurement range switchover
Interface modules - 19" rack unit and wall-mounted unit
- Interface module 1.1:
12 relay outputs and 8 digital inputs - Interface module 2.1:
1 analog output for each measuring component (0/4 to 20 mA or configurable according to NAMUR), plus 3 relay outputs for each module - Interface module 2.2:
One analog output for each measured component (0/4 to 20 mA or configurable according to NAMUR), 4 analog inputs and 4 digital inputs
- Field control unit
- Interface module 2.2:
4 analog inputs 0/4 to 20 mA
|
|