Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6ES7352-5AH01-0AE0

6ES7352-5AH11-0AE0

FM 352-5, BOOLEAN PROCESSOR 12DE/8DA

FM 352-5 PNP, BOOLEAN PROCESSOR 12DI/8DO

Supply voltage

Rated value (DC)

  • 24 V DC

Yes

Yes

Load voltage L+

  • Rated value (DC)

24V

24V

  • permissible range, lower limit (DC)

20.4V

20.4V

  • permissible range, upper limit (DC)

28.8V

28.8V

  • Reverse polarity protection

Yes

Yes

Input current

from load voltage1L+, max.

150mA; typ. 60 mA

150mA; typ. 60 mA

from load voltage 2L+ (without load), max.

200mA; typ. 60 mA, DI/DO supply

200mA; typ. 60 mA, DI/DO supply

from load voltage 3L+ (with encoder), max.

600mA; typ. 80 mA plus encoder supply

600mA; typ. 80 mA plus encoder supply

from load voltage 3L+ (without encoder), max.

200mA; typ. 80 mA

200mA; typ. 80 mA

from backplane bus 5 V DC, typ.

135mA

135mA

Encoder supply

5 V encoder supply

  • 5 V

Yes

Yes

  • short-circuit protection

Yes; Electronic overload protection; no protection on applying a normal or counter voltage.

Yes; Electronic overload protection; no protection on applying a normal or counter voltage.

  • Output current, max.

250mA

250mA

24 V encoder supply

  • 24 V

Yes

Yes

  • Short-circuit protection

Yes; Overvoltage and overheating protection if overloaded; diagnostics if output reaches temperature limit; no protection on applying a normal or counter voltage

Yes; Overvoltage and overheating protection if overloaded; diagnostics if output reaches temperature limit; no protection on applying a normal or counter voltage

  • Output current, max.

400mA

400mA

Power loss

Power loss, typ.

6.5W

6.5W

Memory

Type of memory

RAM

RAM

Memory size

128kbyte; required for operation, MMC

128kbyte; required for operation, MMC

Digital inputs

Number of digital inputs

8; Standard and up to 12 with 24 V DC encoder inputs as digital inputs

8; Standard and up to 12 with 24 V DC encoder inputs as digital inputs

Input voltage

  • Rated value (DC)

24V

24V

  • for signal "0"

-30 to +5V

-30 to +5V

  • for signal "1"

+11 to +30V

+11 to +30V

Input current

  • for signal "0", max. (permissible quiescent current)

1.5mA

1.5mA

  • for signal "1", typ.

3.8mA

3.8mA

Input delay (for rated value of input voltage)

  • Input frequency (with a time delay of 0.1 ms), max.

200kHz

200kHz

  • programmable digital filter delay

None, 5 s, 10 s, 15 s, 20 s, 50 s, 1.6 ms

None, 5 s, 10 s, 15 s, 20 s, 50 s, 1.6 ms

  • Minimum pulse width for program reactions

1 s, 5 s, 10 s, 15 s, 20 s, 50 s, 1,6 ms

1 s, 5 s, 10 s, 15 s, 20 s, 50 s, 1,6 ms

for standard inputs

  • at "0" to "1", max.

3s; typ. 1.5 s

3s; typ. 1.5 s

Cable length

  • shielded, max.

600m

600m

  • unshielded, max.

100m; Shielded cable recommended if filtering delay is set to less than 1.6 ms

100m; Shielded cable recommended if filtering delay is set to less than 1.6 ms

Digital outputs

Number of digital outputs

8

8

Current-sinking

Yes

No

Current-sourcing

No

Yes

Short-circuit protection

Yes; Overvoltage protection, thermal protection

Yes; Overvoltage protection, thermal protection

  • Response threshold, typ.

1.7 to 3.5 A

1.7 to 3.5 A

Limitation of inductive shutdown voltage to

2M -45 V typ., (-40 V to -55 V); comment: no protection against inductive kickback >55 mJ

2M -45 V typ., (-40 V to -55 V); comment: no protection against inductive kickback >55 mJ

Controlling a digital input

No

Yes

Switching capacity of the outputs

  • on lamp load, max.

5W

5W

Output voltage

  • Rated value (DC)

24V

24V

  • for signal "0", max.

28.8V

28.8V

  • for signal "1", max.

0.5V

0.5V

Output current

  • for signal "1" rated value

0.5A; At 60 C

0.5A; At 60 C

  • for signal "1" permissible range for 0 to 60 C, min.

5mA

5mA

  • for signal "1" permissible range for 0 to 60 C, max.

600mA

600mA

  • for signal "0" residual current, max.

1mA

1mA

Output delay with resistive load

  • "0" to "1", max.

1s; 0.6 s 50 mA / 1.0 s 0.5 A

1s; 0.6 s 50 mA / 1.0 s 0.5 A

  • "1" to "0", max.

1.5s; 1.7 s 50 mA / 1.5 s 0.5 A

1.5s; 1.7 s 50 mA / 1.5 s 0.5 A

Parallel switching of two outputs

  • for uprating

Yes; 2

Yes; 2

Switching frequency

  • with resistive load, max.

100kHz; 20 kHz at 0.5 A; 100 kHz at 0.25 A

100kHz; 20 kHz at 0.5 A; 100 kHz at 0.25 A

  • with inductive load, max.

2Hz; 2 Hz at 0.5 A with external commutator diodes; 0.5 Hz at 0.5 A without external commutator diodes

2Hz; 2 Hz at 0.5 A with external commutator diodes; 0.5 Hz at 0.5 A without external commutator diodes

  • on lamp load, max.

10Hz

10Hz

Cable length

  • shielded, max.

600m

600m

  • unshielded, max.

100m

100m

Encoder

Connectable encoders

  • Incremental encoder (symmetrical)

Yes

Yes

  • Incremental encoder (asymmetrical)

Yes

Yes

  • Absolute encoder (SSI)

Yes

Yes

  • 2-wire sensor

Yes

Yes

  • permissible quiescent current (2-wire sensor), max.

1.5mA

1.5mA

Encoder signals, incremental encoder (symmetrical)

  • Trace mark signals

A, notA, B, notB

A, notA, B, notB

  • Zero mark signal

N, notN

N, notN

  • Input voltage

5 V difference signal (phys. RS 422)

5 V difference signal (phys. RS 422)

  • Input frequency, max.

500kHz

500kHz

  • Cable length, shielded, max.

100m; 100 m with 24 V supply and 500 kHz; 32 m with 5 V supply and 500 kHz

100m; 100 m with 24 V supply and 500 kHz; 32 m with 5 V supply and 500 kHz

Encoder signals, incremental encoder (asymmetrical)

  • Trace mark signals

A, B

A, B

  • Zero mark signal

N

N

  • Input voltage

24 V

24 V

  • Input frequency, max.

200kHz

200kHz

  • Cable length, shielded, max.

50m; Cable length, HTL incremental encoder, Siemens, type 6FX2001-4: 50 kHz, 25 m shielded, max., 25 kHz, 50 m shielded, max.

50m; Cable length, HTL incremental encoder, Siemens, type 6FX2001-4: 50 kHz, 25 m shielded, max., 25 kHz, 50 m shielded, max.

Encoder signals, absolute encoder (SSI)

  • Data signal

DATA, notDATA

DATA, notDATA

  • Clock signal

CK, notCK

CK, notCK

  • Telegram length, parameterizable

13 or 25 bit

13 or 25 bit

  • Clock frequency, max.

1MHz; 125 kHz, 250 kHz, 500 kHz or 1 MHz

1MHz; 125 kHz, 250 kHz, 500 kHz or 1 MHz

  • Cable length, shielded, max.

320m; At 125 kHz

320m; At 125 kHz

  • Monoflop time

settable: 16/32/48/64 s

settable: 16/32/48/64 s

  • Listening mode

Yes; one or two stations

Yes; one or two stations

  • Multiturn

Yes; 25 bit message frame

Yes; 25 bit message frame

Encoder signal evaluation

  • Counting direction, forward

Yes

Yes

  • Counting direction, backward

Yes

Yes

Response times

Input- to output response time

5 V input to 24 V output, 0 filter: 1 to 4 s (typ.); 24 V input to 24 V output, 0 filter: 2 to 6 s (typ.)

5 V input to 24 V output, 0 filter: 1 to 4 s (typ.); 24 V input to 24 V output, 0 filter: 2 to 6 s (typ.)

Interfaces

Point-to-point

  • Updating times

PLC interface: 1.7 ms

PLC interface: 1.7 ms

Interrupts/diagnostics/status information

Alarms

  • Diagnostic alarm

Yes; 1L, 2L, 3L missing; MMC error; output overload (8); encoder supply overload; differential wire break; parameterization errror; SSI message frame overflow

Yes; 1L, 2L, 3L missing; MMC error; output overload (8); encoder supply overload; differential wire break; parameterization errror; SSI message frame overflow

  • Hardware interrupt

Yes; 8 available; for generation by user program

Yes; 8 available; for generation by user program

Diagnostic messages

  • Wire-break in signal transmitter cable

Yes

Yes

  • Overflow/underflow

Yes

Yes

  • missing load voltage

Yes

Yes

Diagnostics indication LED

  • RUN/STOP LED

Yes

Yes

  • Module supply 5 V DC (green)

Yes

Yes

  • I/O status IOF (red)

Yes

Yes

  • Micro Memory Card error MCF (red)

Yes

Yes

  • Group error SF (red)

Yes

Yes

  • Status indicator digital input (green)

Yes; I 0 to I 11

Yes; I 0 to I 11

  • Status indicator digital output (green)

Yes; Q 0 to Q 7

Yes; Q 0 to Q 7

  • Overload encoder supply voltage 24 V F (red)

Yes

Yes

  • Overload encoder supply voltage 5 V F (red)

Yes

Yes

Counter

Counting range, description

Counting range (16-bit counters): -32,768 to 32,767 (user-specific within this range); counting range (32-bit counters): -2,147,483,648 to 2,147,483,647 (user-specific within this range)

Counting range (16-bit counters): -32,768 to 32,767 (user-specific within this range); counting range (32-bit counters): -2,147,483,648 to 2,147,483,647 (user-specific within this range)

Counting range, lower limit

-2147483648

-2147483648

Counting range, upper limit

2147483647

2147483647

Counting mode

  • Counting mode, individual

Yes

Yes

  • Counting mode, continuous

Yes

Yes

  • Counting mode, periodic

Yes

Yes

Potential separation

between 1L and 2L and 3L

Yes

Yes

Potential separation digital inputs

  • Potential separation digital inputs

Yes; Yes CPU, I/O and sensor units are isolated

Yes; Yes CPU, I/O and sensor units are isolated

Degree and class of protection

Degree of protection acc. to EN 60529

  • IP20

Yes

Yes

Ambient conditions

Ambient temperature during operation

  • min.

0C

0C

  • max.

60C

60C

Ambient temperature during storage/transportation

  • min.

-40C

-40C

  • max.

70C

70C

Configuration

Programming

  • Program cycle time (scan)

1s

1s

Connection method

required front connector

1x 40-pin

1x 40-pin

Dimensions

Width

80mm

80mm

Height

125mm

125mm

Depth

120mm

120mm

Weights

Weight, approx.

434g; Module weight: approx. 434 g (with 1L connection and without I/O connection or MMC); shipping weight: approx. 500 g (with bus and 1L connection and without I/O connection or MMC)

434g; Module weight: approx. 434 g (with 1L connection and without I/O connection or MMC); shipping weight: approx. 500 g (with bus and 1L connection and without I/O connection or MMC)


















2018
Siemens Industry Catalog Drive technology Automation technology Automation systems SIMATIC Industrial Automation Systems Controllers I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP SIMATIC ET 200MP SIMATIC ET 200S SIMATIC ET 200M Interface modules SIPLUS Interface modules I/O modules Digital modules Analog modules Analog modules with HART F digital/analog modules Ex digital modules Ex analog modules Function modules FM 350-1 counter module FM 350-2 counter module FM 351 positioning module FM 352 cam controllers FM 352-5 high-speed Boolean processor FM 353 positioning module FM 354 positioning module FM 355 controller module FM 355-2 temperature controller module SM 338 POS input module SIPLUS function modules Special modules Communication Connection system Power supplies SIMATIC ET 200iSP SIMATIC ET 200 systems without control cabinet IO systems for heating elements PROFIBUS components PROFINET components Network components for PROFIBUS Network transitions SIMATIC control systems Software for SIMATIC Controllers Programming devices Siemens Partner Programm SIMOTION Motion Control System SINUMERIK CNC automation systems System cabling/control cabinets Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.