1.0 (factory setting) can be altered by input of a reactive current setpoint
Total (?)
1.0 (factory setting)
Overvoltage category
According to EN 60664?1
Class III
DC link voltage Vd
The DC link voltage is regulated and can be adjusted as a voltage decoupled from the line voltage.
Factory setting for DC link voltage: 1.5 ? line voltage
Electronic power supply
24 V DC, -15 %/+20 %
Radio interference suppression
Standard With Active Interface Module
Category C3 according to EN 61800?3
Cooling method
Increased air cooling by means of built-in fan
Permissible ambient or coolant temperature (air)
In operation for line-side components, Line Modules and Motor Modules
0 … 40 °C (32 … 104 °F) without derating, > 40 … 55 °C (104 … 131 °F), see derating characteristics
Installation altitude
Up to 2000 m (6562 ft) above sea level without derating, > 2000 ... 4000 m (6562 ... 13124 ft) above sea level, see derating characteristics
Declarations of conformity
CE (Low Voltage and EMC Directives)
Approvals, according to
cULus
Line voltage 380 … 480 V 3 AC
Active Line Module in chassis format
6SL3330?...
7TE32-1AA3
7TE32-6AA3
7TE33-8AA3
7TE35-0AA3
Infeed/regenerative feedback power
Rated power Prated
At 400 V 3 AC
kW
132
160
235
300
At 460 V 3 AC 2)
(HP)
(200)
(225)
(350)
(450)
Pmax
kW
198
240
352,5
450
DC link current
Rated current Irated_DC
A
235
291
425
549
IH_DC
A
209
259
378
489
Imax_DC
A
352
436
637
823
Input current
Rated current at 400 V 3 AC
A
210
260
380
490
Maximum
A
315
390
570
735
Power requirement
24 V DC electronic power supply, max.
A
1.1
1.1
1.35
1.35
Fan supply at 400 V 2 AC, 50/60 Hz, max.
A
0.63/0.95
1.13/1.7
1.8/2.7
1.8/2.7
DC link capacitance
µF
4200
5200
7800
9600
Power loss, max.
kW
2.3
2.9
4.2
5.1
Cooling air requirement
m3/s (ft3/s)
0.17 (6.0)
0.23 (8.1)
0.36 (12.7)
0.36 (12.7)
Sound pressure level
LpA (1 m) 1) at 50/60 Hz
dB
74/76
75/77
76/78
76/78
Line connection
U1, V1, W1
Flat connector for M10 screw
Flat connector for M10 screw
Flat connector for M10 screw
Flat connector for M10 screw
Conductor cross-section, max.
mm2
2 ? 185
2 ? 185
2 ? 185
2 ? 185
DC link connection
DCP, DCN
Flat connector for M10 screw
Flat connector for M10 screw
Flat connector for M10 screw
Flat connector for M10 screw
Conductor cross-section, max.
mm2
2 ? 185
2 ? 185
2 ? 185
2 ? 185
PE connection
M10 screw
M10 screw
M10 screw
M10 screw
Conductor cross-section, max.
PE1/GND
mm2
1 ? 185
1 ? 185
1 ? 185
1 ? 185
PE2/GND
mm2
2 ? 185
2 ? 185
2 ? 185
2 ? 185
Cable length, max.
Total of all motor cables and DC link
Shielded
m (ft)
2700 (8859)
2700 (8859)
2700 (8859)
2700 (8859)
Unshielded
m (ft)
4050 (13288)
4050 (13288)
4050 (13288)
4050 (13288)
Degree of protection
IP20
IP20
IP20
IP20
Dimensions
Width
mm (in)
326 (12.83)
326 (12.83)
326 (12.83)
326 (12.83)
Height
mm (in)
1400 (55.12)
1400 (55.12)
1533 (60.35)
1533 (60.35)
Depth
mm (in)
356 (14.02)
356 (14.02)
543 (21.38)
543 (21.38)
Frame size
FX
FX
GX
GX
Net weight
kg (lb)
95 (209)
95 (209)
136 (300)
136 (300)
1) Total sound pressure level of Active Interface Module and Active Line Module.
2) Nominal HP ratings are provided for ease of assigning components only. The Line Module outputs are dependent on the Motor Module loading and are to be dimensioned accordingly.