General technical data: | | |
product brand name | | SIDOOR |
Product designation | | Door controller |
Product expansion optional | | Mains transformer 6FB1112-0AT20-2TR0 |
Design of the product | | ATD420W |
Supply voltage: | | |
Type of voltage supply | | via SIDOOR mains transformer / NT40 |
Operating current of fuse protection at input when installing | | 6 ... 10 |
Consumed current maximum | A | 10 |
I2t value minimum | A?·s | 30 |
Active power consumption | | |
| W | 80 |
| W | 540 |
| W | 5 |
Inputs/ Outputs: | | |
Input voltage per DC input | V | 10 ... 28 |
Input current per DC input | mA | 9 ... 27 |
Product property | | |
| | Yes |
| | Yes |
Output current at 24 V DC output maximum | mA | 400 |
Property of the 24 V DC output | | |
| | CAUTION: Do not supply with external voltage! |
| | Yes |
| | Yes |
Switching capacity current of the output relay at DC at 30 V | | 0.01 ... 0.5 |
Door-relevant data: | | |
Door opening width | m | 0.3 ... 5 |
Weight of door maximum | kg | 600 |
Operating cycle frequency of door maximum | 1/h | 180 |
Kinetic energy maximum | J | 4 |
Communication: | | |
Design of the interface | | PROFIBUS according to IEC 61784-3 |
Number of bus nodes | | 32 |
Ambient conditions: | | |
Ambient temperature during operation | °C | -20 ... +50 |
Ambient temperature during storage | °C | -40 ... +70 |
Relative humidity without condensation | | 10 ... 93 |
Protection class IP | | IP20 |
Installation/ mounting/ dimensions: | | |
Width | mm | 320 |
Height | mm | 60 |
Depth | mm | 80 |
Installation or assembly note | | no direct solar irradiation, optional standard rail mounting possible using accessory 6FB1144-0AT00-3AS0 |
Standards: | | |
Certificate of suitability CE marking | | Yes |
Certificate of suitability acc. to EN 81 | | No |
Standard for EMC | | EN 61000-6-2 / EN 61000-6-4 |
Standard for safety | | ISO 13849-1 PLd CAT2 |