6SL3210-...
|
5DE12-4UA0
|
5DE13-5UA0
|
5DE16-0UA0
|
5DE17-8UA0
|
5DE21-0UA0
|
5DE21-4UA0
|
5DE21-8UA0
|
|
Frame size
|
FSA
|
FSB
|
FSC
|
|
Input voltage
|
380 ... 480 V 3 AC -15 %/+10 %
|
|
Input frequency
|
50 ... 60 Hz ± 10 %
|
|
Infeed
|
Non-stabilized
|
|
Electronics power supply
|
24 V DC ± 10 %
|
|
24 V DC supply
|
2.0 A (4.0 A) combined with motors without brake (with brake)
|
|
Cooling
|
Natural cooling
|
Forced ventilation
|
|
Ambient temperature
|
|
|
|
-40 ... +70 °C
|
|
|
0 ... 45 °C without derating, > 45 ... 55 °C with derating (derating by 0 % at 45 °C up to 20 % at 55 °C)
|
|
Air humidity
|
|
|
|
90 % (non-condensing)
|
|
|
< 90 % (non-condensing)
|
|
Ambient conditions
|
Indoor (without sunshine), without corrosive gas, combustible gas, oil gas, nor dust
|
|
Installation altitude
|
Up to 1000 m without derating
|
|
Connectable motors
|
SIMOTICS S-1FL6
|
|
Degree of protection
|
IP20
|
|
Encoder evaluation
|
Absolute encoder 20 bit/Incremental encoder with 2500 S/R (13 bit resolution through electronic multiplication)
|
|
Output current
|
|
|
|
1.2 A
|
3.0 A
|
4.6 A
|
5.3 A
|
7.8 A
|
11.0 A
|
13.2 A
|
|
|
3.6 A
|
9.0 A
|
13.8 A
|
15.9 A
|
23.4 A
|
33.0 A
|
39.6 A
|
|
Rated output power Prated
|
0.4 kW
|
1 kW
|
1.5 kW
|
1.75 kW
|
2.5 kW
|
3.5 kW
|
7 kW
|
|
Power loss
|
36 W
|
47 W
|
54 W
|
70 W
|
47 W
|
54 W
|
70 W
|
|
Cooling air required
|
0.005 m3/s
|
0.005 m3/s
|
0.005 m3/s
|
0.005 m3/s
|
0.005 m3/s
|
0.005 m3/s
|
0.005 m3/s
|
|
Conductor cross-section, max.
|
1.5 mm2
|
2.5 mm2
|
|
Dimensions1)
|
|
|
|
80 mm
|
100 mm
|
140 mm
|
|
|
180 mm
|
180 mm
|
260 mm
|
|
|
200 mm
|
200 mm
|
240 mm
|
|
Weight, approx.
|
1.85 kg
|
2.45 kg
|
5.65 kg
|
|
Certification
|
CE
|