SITRANS FUT1010
|
|
|
Input
|
|
|
Flow range (Gas)
|
± 36.5 m/s (± 120 f/s) for DN 100 ... DN 200 (4" ... 8") pipes bi-directional
± 30.5 m/s (± 100 ft/s) for DN 250 ... DN 600 (10" ... 24") pipes bi-directional
|
|
Flow range (Liquid)
|
± 12 m/s (± 40 f/s) including zero flow, bi-directional
|
|
Flow sensitivity
|
0.0003 m/s (0.001 f/s) flow rate independent
|
|
Flow temperature range
|
-28 ... +93 °C (-20 ... +200°F)
|
|
Analog inputs
|
4 x 4 ... 20 mA, (Programmable to Density, Pressure, viscosity or Temperature)
|
|
Output
|
|
|
Standard outputs
|
- 4x isolated 4 ... 20 mA, programmable
- 2x 0 ... 10 V DC, programmable
- 4x Digital Pulse outputs (2x open collector and 2x 0-5V TTL) One each for positive flow, one each for negative flow
- Standard VT100 RS 232, Optional HART, BACnet MSTP/BACnet IP, Modbus RTU & TCP/IP, Ethernet IP, Johnson N2
|
|
Status/Alarm I/O
|
- Programmable, 4x Form C Relays
- Clear Switch Input Totalizer Hold Switch Input
|
|
Calibrated accuracy
|
|
|
Gas
|
|
|
|
0.5 ... 1.0 % (4” ... 6” < 0.15 %)
|
|
|
< 0.5 %
|
|
|
< 0.2 %
|
|
Liquid
|
|
|
|
0.5 ... 1.0 % (4” ... 6” < 0.25 %)
|
|
|
< 0.5 %
|
|
|
< 0.15 %
|
|
Repeatability
|
± 0.05 ... 0.1 %
|
|
Data refresh rate
|
5 Hz
|
|
Design
|
|
|
Design Flow transmitter
|
|
|
Dimensions
|
see SITRANS F US Clamp-on “System info and selection guide“
|
|
Weight
|
see diagrams
|
|
Power supply
|
|
|
Power supply
|
90 ... 240 V AC, 50 … 60 Hz, 30 VA or 9 ... 36 V DC, 12 W
|
| |
|
|
Indication and operation
|
|
|
Data logger memory
|
1 MByte, programmable for all available data variables
|
|
Display
|
128 x 240 pixel LCD with backlight
|
|
Keypad
|
33 keypad buttons with tactile feedback
|
|
Language options
|
English, Spanish, German, Italian, French
|
|
Design Flow sensor
|
|
|
Nominal pipe sizes
|
4" ... 24" (DN 100 ... DN 600)
|
|
Pipe material specification
|
API 5L ERW
|
|
Temperature tap
|
?"
|
|
Pressure tap
|
?"
|
|
Flange class
|
|
|
|
150, 300, 600
|
|
|
300, 600
|
|
Flange specification
|
- ASME B16.5
- Liquid 150, 300, 600
- Gas 300, 600
|
|
Flange facing
|
Raised face weld neck
|
|
Flange material
|
A105
|
|
Flow sensor paths
|
Two, three, or four
|
|
Sensor length
|
See diagram
|
|
Design temperature
|
-28 ... +93 °C (-20 ... +200 °F)
|
|
Exterior finish
|
Marine/offshore grade per ASTM B117
|
|
Optional pipe sections
|
- 10 D upstream (with optional flow conditioner)
- 5 D downstream
|
|
Certificates and approvals
|
|
|
Flow transmitter IP65 (NEMA 4X)
|
|
|
FM and CSA
|
N-I Class I, Div 2 S Class II, Div 2
I.S. Class I, II, Div 1
|
|
ATEX
|
Ex II (1) G [Ex ia] IIC Ex II 3 (1) G Ex nC [ia] IIC T5
|
|
CE markings
|
EMC 2004/108/EC ATEX 94/9/EC
|
|
Flow Transmitter - IP66 (NEMA 7)
|
|
|
FM and CSA
|
Ex Class I, Div 1 D-I Class II, Div 1 N-I Class I, Div 2 S Class II, Div 2
I.S. Class I, II, Div 1
|
|
ATEX
|
Ex II (1) G [Ex ia] IIC Ex II 3 (1) G Ex nC [ia] IIC T5 Ex II 2 (1) G Ex d [ia IIC] IIB + H2 T5
|
|
CE markings
|
EMC 2004/108/EC ATEX 94/9/EC
|
|
Sensor
|
|
|
FM and CSA
|
I.S. Class I, Div 1 N-I Class I, Div 2 S Class II, Div 2
|
|
ATEX
|
Ex II 1 G Ex ia IIC T5
|
|
CE markings
|
EMC 2004/108/EC PED 97/23/EEC ATEX 94/9/EC
|