The Smart Line Modules in booksize format feature the following connections and interfaces as standard: - 1 power connection via screw-type terminals
- 1 connection for the 24 V DC electronics power supply via the 24 V terminal adapter included in the scope of supply
- 1 DC link connection via integrated DC link busbars
- 2 PE (protective earth) connections
- 2 digital inputs
(only for Smart Line Modules 5 kW (5 hp) and 10 kW (10 hp)) - 1 digital output
(only for Smart Line Modules 5 kW (5 hp) and 10 kW (10 hp)) - 3 DRIVE‑CLiQ sockets
(only for Smart Line Modules 16 kW (18 hp), 36 kW (40 hp) and 55 kW (60 hp)) - 1 temperature sensor input for KTY84‑130, Pt1000 or PTC (only for Smart Line Modules 16 kW (18 hp), 36 kW (40 hp) and 55 kW (60 hp), Pt1000 can be used from firmware V4.7 HF17)
The status of the Smart Line Modules is indicated via two multi-color LEDs. The signal cable shield can be connected to the Line Module by means of a shield connection terminal, e.g. Weidmüller type KLBÜ 3-8 SC. The scope of supply of the Smart Line Modules includes: - DRIVE‑CLiQ cable for connecting the module to the adjacent Control Unit on the left with the drive control, length 0.11 m (4.33 in)
(only for Smart Line Modules 16 kW (18 hp), 36 kW (40 hp) and 55 kW (60 hp)) - 2 blanking plugs for closing unused DRIVE-CLiQ sockets
(only for Smart Line Modules 16 kW (18 hp), 36 kW (40 hp) and 55 kW (60 hp)) - DRIVE‑CLiQ cable (length depends on Smart Line Module width) for connection to the adjacent Motor Module, length = width of Smart Line Module + 0.11 m (4.33 in)
- Jumper for connecting the 24 V DC busbar to the adjacent Motor Module
- 24 V terminal adapter (X24)
- Connector X21 for digital inputs and outputs
- Connector X22 for digital inputs and outputs
(only for Smart Line Modules 5 kW (5 hp) and 10 kW (10 hp)) - Connector X1 for line connection
(only for Smart Line Modules 5 kW (5 hp) and 10 kW (10 hp)) - 1 set of warning labels in 30 languages
|
|