DC link voltage 510 ... 720 V DC | Braking Module in booksize compact format Internal air cooling 6SL3400-1AE31-0AA1 |
|---|
Rated power PDB | 5 kW (2.5 kW) 1) 2) | Peak power Pmax | 100 kW (50 kW) 1) 2) | Activation threshold | 775 V (410 V) 1) | Cable length to braking resistor, max. | 10 m (32.8 ft) | DC link capacitance | 6 μF | Current requirement with 24 V DC, max. | 0.5 A | Digital inputs In accordance with IEC 61131‑2 Type 1 | | | -3 V ... +30 V | - Low level
(an open digital input is interpreted as "low")
| -3 V ... +5 V | | 15 ... 30 V | - Current consumption at 24 V DC, typ.
| 10 mA | - Conductor cross-section, max.
| 1.5 mm2 | Digital outputs (sustained-short-circuit-proof) | | | 24 V DC | - Load current per digital output, max.
| 100 mA | - Conductor cross-section, max.
| 1.5 mm2 | Current carrying capacity | | | 20 A | | 100 A | PE connection | M5 screw | Dimensions | | | 50 mm (1.97 in) | | 270 mm (10.63 in) | | 226 mm (8.90 in) | Weight, approx. | 2.7 kg (5.95 lb) | Certificate of suitability | cURus |
1) The activation threshold of the Braking Module in booksize compact format can be set on a DIP switch. The higher values for peak or rated braking power apply in operation at the upper activation threshold 775 V DC (factory setting). The outputs specified in parentheses are possible at the lower activation threshold 410 V DC. 2) Several Braking Modules in the booksize format can be operated in parallel, typically up to 4 modules.
|
|