General information | | |
Product brand name | SIDOOR |
Product designation | Door controller |
Product version | ATE500E Relais | ATE500E CAN |
Optional product expansion | Mains transformer (6FB1112-0AT20-2TR0), NT40 (6FB1112-0AT20-3PS0) |
Manufacturer's article no. of the usable motor | 6FB1203-0AT12-7DA0 |
Manufacturer's article no. of the usable power supply unit | 6FB1112-0AT20-2TR0, 6FB1112-0AT20-3PS0 |
Installation type/mounting | | |
Installation and mounting instructions | No direct sunlight, requirements specific to the end application must be observed. NFPA industry environment: Installation outside a control cabinet only horizontal. NFPA elevator environment: Must be installed in a fire protection enclosure |
Supply voltage | | |
Rated value (DC) | 36 V; with MED280: At 24 V DC max. door speed of 500 mm/s; at 28.8 V DC max. door speed of 800 mm/s |
Input current | | |
IІt, min. | 30 AІ·s |
Power | | |
Active power input (standby mode) | 5 W | 6 W |
Digital inputs | | |
Control inputs isolated | Yes |
Control inputs p-switching | Yes |
Protection in case of DC supply | Use of a circuit breaker in the supply path according to 60898-1, 8A, C-characteristic type SIEMENS: 5SY4108-7 or 5SY4108-7KK11 |
Input voltage | | |
| 10 V; Observe polarity ! |
| 28 V; Observe polarity ! |
Input current | | |
| 3 mA |
| 15 mA |
Digital outputs | | |
short-circuit proof | Yes |
Overload-proof | Yes |
Remark | Ensure correct polarity! CAUTION: Do not supply with external voltage! |
Output voltage | | |
| 24 V |
Output current | | |
| 400 mA |
Relay outputs | | |
Switching capacity of contacts | | |
| 0.01 A |
| 1 A | 0.5 A |
| 0.01 A; 50 V DC switching voltage not released for NFPA-relevant countries | |
| 1 A; 50 V DC switching voltage not released for NFPA-relevant countries | |
| 0.01 A | |
| 1 A | |
Mechanical data | | |
Opening width of door, min. | 0.3 m |
Opening width of door, max. | 5 m |
Weight of door, max. | 280 kg |
Operating cycle frequency of door, max. | 180 1/h |
Kinetic energy, max. | 75 J |
Counterweight | | |
| 6 kg |
Interfaces | | |
Interfaces/bus type | without | CANopen, CiA standard 301, profile 417 |
Number of bus nodes | | 32 |
Isolation | | |
Overvoltage category | 2 |
Degree and class of protection | | |
IP degree of protection | IP20 |
Standards, approvals, certificates | | |
Certificate of suitability according to EN 81 | Yes |
CE mark | Yes |
UL approval | Yes |
EAC (formerly Gost-R) | Yes |
TГњV Inspectorate approval | Yes |
TГњV prototype tested | Yes |
China RoHS compliance | Yes |
Standard for EMC | EN 12015 / EN 12016 / EN 61000-6-2 / EN 61000-6-4 / EN 61326-3-1 |
Standard for safety | EN 60335-1 / EN 60950-1 / EN 81-20 / UL 61010-1 / UL 61010-2-201 / EN ISO 13849-1 Cat. 2 PL d / IEC 62061: SIL 2 |
Ambient conditions | | |
Ambient temperature during operation | | |
| -25 °C |
| 50 °C |
| Bolt the controller onto a metal mounting surface so that thermal conductivity is ensured |
Ambient temperature during storage/transportation | | |
| -40 °C |
| 85 °C |
Air pressure acc. to IEC 60068-2-13 | | |
| 2 000 m |
Relative humidity | | |
| 10 % |
| 93 % |
Mechanics/material | | |
Service life | | |
| 19 y |
Dimensions | | |
Width | 320 mm |
Height | 60 mm |
Depth | 80 mm |