Article number

6ES7677-2AA31-0EB0

6ES7677-2AA41-0FB0

CPU 1515SP PC 4GB

CPU 1515SP PC 4GB

General information

 

 

Product type designation

CPU 1515SP PC

CPU 1515SP PC

HW functional status

FS06

FS05

Firmware version

V2.1

V2.1

Engineering with

 

 

  • â—� STEP 7 TIA Portal configurable/integrated as of version

V14 SP1

V14 SP1

Installed software

 

 

  • â—� Visualization

No

No

  • â—� Control

S7-1500 Software Controller CPU 1505SP V2.1

S7-1500 Software Controller CPU 1505SP V2.1

Configuration control

 

 

via dataset

Yes

Yes

Control elements

 

 

Mode selector switch

1

1

Supply voltage

 

 

Type of supply voltage

24 V DC

24 V DC

permissible range, lower limit (DC)

19.2 V

19.2 V

permissible range, upper limit (DC)

28.8 V

28.8 V

Reverse polarity protection

Yes

Yes

Mains buffering

 

 

  • â—� Mains/voltage failure stored energy time

5 ms

5 ms

Input current

 

 

Current consumption (rated value)

1.5 A; Full processor load, incl. ET 200SP modules and using USB

1.5 A; Full processor load, incl. ET 200SP modules and using USB

Current consumption (in no-load operation), typ.

0.6 A

0.6 A

Inrush current, max.

4.7 A; Rated value

4.7 A; Rated value

Power

 

 

Active power input, max.

36 W; incl. ET 200SP modules and using USB

36 W; incl. ET 200SP modules and using USB

Infeed power to the backplane bus

8.75 W

8.75 W

Power loss

 

 

Power loss, typ.

15 W; without ET 200SP modules and without using USB

15 W; without ET 200SP modules and without using USB

Processor

 

 

Processor type

Dual-Core 1 GHz, AMD G Series APU T40E

Dual-Core 1 GHz, AMD G Series APU T40E

Memory

 

 

Type of memory

DDR3-SDRAM

DDR3-SDRAM

Main memory

4 GB RAM

4 GB RAM

Flash Disk

30 GB

30 GB

CFast memory card

Yes; 30 GB flash memory

Yes; 30 GB flash memory

SIMATIC memory card required

No

No

Work memory

 

 

  • â—� integrated (for program)

1 Mbyte

1 Mbyte

  • â—� integrated (for data)

5 Mbyte

5 Mbyte

  • â—� integrated (for CPU function library of CPU Runtime)

10 Mbyte

10 Mbyte

Load memory

 

 

  • â—� integrated (on PC mass storage)

320 Mbyte

320 Mbyte

Backup

 

 

  • â—� with UPS

Yes; all memory areas declared retentive

Yes; all memory areas declared retentive

  • â—� with non-volatile memory

Yes

Yes

CPU processing times

 

 

for bit operations, typ.

10 ns

10 ns

for word operations, typ.

12 ns

12 ns

for fixed point arithmetic, typ.

16 ns

16 ns

for floating point arithmetic, typ.

64 ns

64 ns

CPU-blocks

 

 

Number of elements (total)

6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements

6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements

DB

 

 

  • â—� Number, max.

5 999; Number range: 1 to 65535

5 999; Number range: 1 to 65535

  • â—� Size, max.

5 Mbyte

5 Mbyte

FB

 

 

  • â—� Number, max.

5 998; Number range: 1 to 65535

5 998; Number range: 1 to 65535

  • â—� Size, max.

512 kbyte

512 kbyte

FC

 

 

  • â—� Number, max.

5 999; Number range: 1 to 65535

5 999; Number range: 1 to 65535

  • â—� Size, max.

512 kbyte

512 kbyte

OB

 

 

  • â—� Size, max.

1 048 kbyte

1 048 kbyte

  • â—� Number of free cycle OBs

100

100

  • â—� Number of time alarm OBs

20

20

  • â—� Number of delay alarm OBs

20

20

  • â—� Number of cyclic interrupt OBs

20

20

  • â—� Number of process alarm OBs

50

50

  • â—� Number of DPV1 alarm OBs

3

3

  • â—� Number of isochronous mode OBs

1

1

  • â—� Number of technology synchronous alarm OBs

2

2

  • â—� Number of startup OBs

100

100

  • â—� Number of asynchronous error OBs

4

4

  • â—� Number of synchronous error OBs

2

2

  • â—� Number of diagnostic alarm OBs

1

1

Nesting depth

 

 

  • â—� per priority class

24

24

Counters, timers and their retentivity

 

 

S7 counter

 

 

  • â—� Number

2 048

2 048

Retentivity

 

 

  • — adjustable

Yes

Yes

IEC counter

 

 

  • â—� Number

Any (only limited by the main memory)

Any (only limited by the main memory)

Retentivity

 

 

  • — adjustable

Yes

Yes

S7 times

 

 

  • â—� Number

2 048

2 048

Retentivity

 

 

  • — adjustable

Yes

Yes

IEC timer

 

 

  • â—� Number

Any (only limited by the main memory)

Any (only limited by the main memory)

Retentivity

 

 

  • — adjustable

Yes

Yes

Data areas and their retentivity

 

 

Retentive data area (incl. timers, counters, flags), max.

410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes

410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes

Flag

 

 

  • â—� Number, max.

16 kbyte

16 kbyte

  • â—� Number of clock memories

8; 8 clock memory bits, grouped into one clock memory byte

8; 8 clock memory bits, grouped into one clock memory byte

Data blocks

 

 

  • â—� Retentivity adjustable

Yes

Yes

  • â—� Retentivity preset

No

No

Local data

 

 

  • â—� per priority class, max.

64 kbyte; max. 16 KB per block

64 kbyte; max. 16 KB per block

Address area

 

 

Number of IO modules

8 192

8 192

I/O address area

 

 

  • â—� Inputs

32 kbyte; All inputs are in the process image

32 kbyte; All inputs are in the process image

  • â—� Outputs

32 kbyte; All outputs are in the process image

32 kbyte; All outputs are in the process image

of which per assigned PC interface

 

 

  • — Inputs (volume)

8 kbyte

8 kbyte

  • — Outputs (volume)

8 kbyte

8 kbyte

Subprocess images

 

 

  • â—� Number of subprocess images, max.

32

32

Hardware configuration

 

 

Integrated power supply

Yes

Yes

Number of distributed IO systems

20

20

Number of DP masters

 

 

  • â—� Via CM

1

1

Rack

 

 

  • â—� Modules per rack, max.

64; CPU 1515SP PC + 64 modules + server module

64; CPU 1515SP PC + 64 modules + server module

  • â—� Number of lines, max.

1

1

PtP CM

 

 

  • â—� Number of PtP CMs

the number of connectable PtP CMs is only limited by the number of available slots

the number of connectable PtP CMs is only limited by the number of available slots

Time of day

 

 

Clock

 

 

  • â—� Type

Hardware clock

Hardware clock

  • â—� Hardware clock (real-time)

Yes; Resolution: 1 s

Yes; Resolution: 1 s

  • â—� Backup time

6 wk; At 40 °C ambient temperature, typically

6 wk; At 40 °C ambient temperature, typically

  • â—� Deviation per day, max.

10 s; Typ.: 2 s

10 s; Typ.: 2 s

Clock synchronization

 

 

  • â—� supported

Yes

Yes

  • â—� to DP, master

No

No

  • â—� on Ethernet via NTP

Yes

Yes

  • â—� on Windows clock, slave

Yes

Yes

Interfaces

 

 

Number of industrial Ethernet interfaces

2

2

Number of PROFINET interfaces

1

1

Number of PROFIBUS interfaces

1

1

Number of RS 485 interfaces

1; Via CM DP module

1; Via CM DP module

Number of USB interfaces

3; 3x USB 2.0 on the front, 500 mA each – of which 2x 500 mA and 1x 100 mA simultaneously

3; 3x USB 2.0 on the front, 500 mA each – of which 2x 500 mA and 1x 100 mA simultaneously

Number of SD card slots

1

1

Video interfaces

 

 

  • â—� Graphics interface

1x DVI-I

1x DVI-I

1. Interface

 

 

Interface type

PROFINET

PROFINET

automatic detection of transmission rate

Yes

Yes

Autonegotiation

Yes

Yes

Autocrossing

Yes

Yes

Interface types

 

 

  • â—� Number of ports

2

2

  • â—� integrated switch

Yes

Yes

  • â—� RJ 45 (Ethernet)

Yes; Via BusAdapter BA 2x RJ45

Yes; Via BusAdapter BA 2x RJ45

  • — Transmission rate, max.

100 Mbit/s

100 Mbit/s

  • — Industrial Ethernet status LED

Yes

Yes

  • â—� BusAdapter (PROFINET)

Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC

Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC

Functionality

 

 

  • â—� Number of connections via this interface

88

88

  • â—� PROFINET IO Controller

Yes

Yes

  • â—� PROFINET IO Device

Yes

Yes

  • â—� SIMATIC communication

Yes

Yes

  • â—� Open IE communication

Yes

Yes

  • â—� Web server

Yes

Yes

PROFINET IO Controller

 

 

Services

 

 

  • — Isochronous mode

Yes

Yes

  • — shortest clock pulse

500 µs

500 µs

  • — IRT

Yes

Yes

  • — MRP

Yes

Yes

  • — MRPD

Yes

Yes

  • — Prioritized startup

Yes; Max. 32 PROFINET devices

Yes; Max. 32 PROFINET devices

  • — Number of connectable IO Devices, max.

128

128

  • — Of which IO devices with IRT, max.

64

64

  • — of which in line, max.

64

64

  • — Number of connectable IO Devices for RT, max.

128

128

  • — of which in line, max.

128

128

  • — Number of IO Devices that can be simultaneously activated/deactivated, max.

8

8

  • — IO Devices changing during operation (partner ports), supported

Yes

Yes

  • — Number of IO Devices per tool, max.

8

8

  • — Updating times

The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

Update time for IRT

 

 

  • — for send cycle of 500 µs

500 µs to 8 ms

500 µs to 8 ms

  • — for send cycle of 1 ms

1 ms to 16 ms

1 ms to 16 ms

  • — for send cycle of 2 ms

2 ms to 32 ms

2 ms to 32 ms

  • — for send cycle of 4 ms

4 ms to 64 ms

4 ms to 64 ms

  • — With IRT and parameterization of "odd" send cycles

Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)

Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)

Update time for RT

 

 

  • — for send cycle of 500 µs

500 µs to 256 ms

500 µs to 256 ms

  • — for send cycle of 1 ms

1 ms to 512 ms

1 ms to 512 ms

  • — for send cycle of 2 ms

2 ms to 512 ms

2 ms to 512 ms

  • — for send cycle of 4 ms

4 ms to 512 ms

4 ms to 512 ms

PROFINET IO Device

 

 

Services

 

 

  • — Isochronous mode

No

No

  • — IRT

Yes

Yes

  • — MRP

Yes

Yes

  • — MRPD

Yes

Yes

  • — Prioritized startup

Yes

Yes

  • — Shared device

Yes

Yes

  • — Number of IO Controllers with shared device, max.

4

4

2. Interface

 

 

Interface type

Integrated Ethernet interface

Integrated Ethernet interface

automatic detection of transmission rate

Yes

Yes

Autonegotiation

Yes

Yes

Autocrossing

Yes

Yes

Interface types

 

 

  • â—� Number of ports

1

1

  • â—� RJ 45 (Ethernet)

Yes; Integrated

Yes; Integrated

  • — Transmission rate, max.

1 000 Mbit/s

1 000 Mbit/s

  • — Industrial Ethernet status LED

No

No

3. Interface

 

 

Interface type

PROFIBUS with CM DP

PROFIBUS with CM DP

Interface types

 

 

  • â—� RS 485

Yes

Yes

Functionality

 

 

  • â—� Number of connections via this interface

44

44

  • â—� PROFIBUS DP master

Yes

Yes

  • â—� PROFIBUS DP slave

Yes

Yes

  • â—� SIMATIC communication

Yes

Yes

DP master

 

 

  • â—� Number of DP slaves, max.

125

125

Services

 

 

  • — Equidistance

No

No

  • — Isochronous mode

No

No

DP slave

 

 

Services

 

 

  • — Equidistance

No

No

  • — Isochronous mode

No

No

RS 485

 

 

  • â—� Transmission rate, max.

12 Mbit/s

12 Mbit/s

Protocols

 

 

Number of connections

 

 

  • â—� Number of connections, max.

88

88

  • â—� Number of connections reserved for ES/HMI/web

10

10

  • â—� Number of S7 routing paths

16

16

SIMATIC communication

 

 

  • â—� PG/OP communication

Yes

Yes

  • â—� S7 routing

Yes

Yes

  • â—� S7 communication, as server

Yes

Yes

  • â—� S7 communication, as client

Yes

Yes

  • â—� User data per job, max.

64 kbyte

64 kbyte

Open IE communication

 

 

  • â—� TCP/IP

Yes

Yes

  • — Data length, max.

64 kbyte

64 kbyte

  • â—� ISO-on-TCP (RFC1006)

Yes

Yes

  • — Data length, max.

64 kbyte

64 kbyte

  • â—� UDP

Yes

Yes

  • — Data length, max.

1 472 kbyte

1 472 kbyte

  • â—� SNMP

Yes

Yes

  • â—� DCP

Yes

Yes

  • â—� LLDP

Yes

Yes

Web server

 

 

  • â—� HTTP

Yes; Via Windows and PROFINET interface

Yes; Via Windows and PROFINET interface

  • â—� HTTPS

Yes; Only via PROFINET interface

Yes; Only via PROFINET interface

OPC UA

 

 

  • â—� OPC UA Server

Data access (read, write, subscribe), runtime license required

Yes; Data access (read, write, subscribe), runtime license required

  • — Application authentication

Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

  • — Security policies

Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

  • — User authentication

"anonymous" or by user name & password

Yes; "anonymous" or by user name & password

Further protocols

 

 

  • â—� MODBUS

Yes; MODBUS TCP

Yes; MODBUS TCP

Media redundancy

 

 

  • â—� Switchover time on line break, typ.

200 ms

200 ms

  • â—� Number of stations in the ring, max.

50

50

S7 message functions

 

 

Number of login stations for message functions, max.

32

32

Program alarms

Yes

Yes

Number of configurable program alarms

10 000

10 000

Number of simultaneously active program alarms

  • â—� Number of program alarms

1 000

1 000

  • â—� Number of alarms for system diagnostics

200

200

  • â—� Number of alarms for motion technology objects

160

160

Test commissioning functions

 

 

Joint commission (Team Engineering)

Yes; Parallel online access possible for up to 8 engineering systems

Yes; Parallel online access possible for up to 8 engineering systems

Status block

Yes; up to 8 simultaneously

Yes; up to 8 simultaneously

Single step

No

No

Status/control

 

 

  • â—� Status/control variable

Yes

Yes

  • â—� Variables

Inputs, outputs, memory bits, DB, times, counters

Inputs, outputs, memory bits, DB, times, counters

  • â—� Number of variables, max.

  • — of which status variables, max.

200

200

  • — of which control variables, max.

200

200

Forcing

 

 

  • â—� Forcing

Yes

Yes

  • â—� Forcing, variables

Inputs, outputs

Inputs, outputs

  • â—� Number of variables, max.

200

200

Diagnostic buffer

 

 

  • â—� present

Yes

Yes

  • â—� Number of entries, max.

1 000

1 000

  • — of which powerfail-proof

300

300

Traces

 

 

  • â—� Number of configurable Traces

4

4

  • â—� Memory size per trace, max.

512 kbyte

512 kbyte

Interrupts/diagnostics/status information

 

 

Diagnostics indication LED

 

 

  • â—� RUN/STOP LED

Yes

Yes

  • â—� ERROR LED

Yes

Yes

  • â—� MAINT LED

Yes

Yes

Supported technology objects

 

 

Motion Control

Yes

Yes

  • â—� Number of available Motion Control resources for technology objects (except cam disks)

2 400

2 400

  • â—� Required Motion Control resources

  • — per speed-controlled axis

40; per axis

40; per axis

  • — per positioning axis

80; per axis

80; per axis

  • — per synchronous axis

160; per axis

160; per axis

  • — per external encoder

80; per external encoder

80; per external encoder

  • — per output cam

20; per cam

20; per cam

  • — per cam track

160; per cam track

160; per cam track

  • — per probe

40; per probe

40; per probe

  • â—� Positioning axis

  • — Number of positioning axes at motion control cycle of 4 ms (typical value)

5

5

  • — Number of positioning axes at motion control cycle of 8 ms (typical value)

12

12

Controller

  • â—� PID_Compact

Yes; Universal PID controller with integrated optimization

Yes; Universal PID controller with integrated optimization

  • â—� PID_3Step

Yes; PID controller with integrated optimization for valves

Yes; PID controller with integrated optimization for valves

  • â—� PID-Temp

Yes; PID controller with integrated optimization for temperature

Yes; PID controller with integrated optimization for temperature

Counting and measuring

  • â—� High-speed counter

Yes

Yes

EMC

 

 

Emission of radio interference acc. to EN 55 011

 

 

  • â—� Limit class A, for use in industrial areas

Yes

Yes

Standards, approvals, certificates

 

 

CE mark

Yes

Yes

CSA approval

Yes

Yes

cULus

Yes

Yes

FM approval

Yes

Yes

RCM (formerly C-TICK)

Yes

Yes

Ambient conditions

 

 

Ambient temperature during operation

 

 

  • â—� min.

0 °C

0 °C

  • â—� max.

Up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load

Up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load

  • â—� horizontal installation, min.

0 °C

0 °C

  • â—� horizontal installation, max.

60 °C

60 °C

  • â—� vertical installation, min.

0 °C

0 °C

  • â—� vertical installation, max.

50 °C; With max. 32 ET 200SP modules and 3x 100 mA USB load

50 °C; With max. 32 ET 200SP modules and 3x 100 mA USB load

Ambient temperature during storage/transportation

 

 

  • â—� min.

-40 °C

-40 °C

  • â—� max.

70 °C

70 °C

Vibrations

 

 

  • â—� Operation, tested according to IEC 60068-2-6

Yes

Yes

  • â—� Transport, tested acc. to IEC 60068-2-6

Yes

Yes

Shock testing

 

 

  • â—� tested according to IEC 60068-2-6

Yes

Yes

  • â—� tested according to IEC 60068-2-27

Yes

Yes

  • â—� tested according to IEC 60068-2-29

Yes

Yes

  • â—� Storage/transport, tested acc. to IEC 60068-2-27

Yes

Yes

Operating systems

 

 

Operating systems

Windows Embedded Standard 7 E 32-bit

Windows Embedded Standard 7 P 64-bit

Configuration

 

 

Programming

 

 

Programming language

 

 

  • — LAD

Yes

Yes

  • — FBD

Yes

Yes

  • — STL

Yes

Yes

  • — SCL

Yes

Yes

  • — CFC

No

No

  • — GRAPH

Yes

Yes

Know-how protection

 

 

  • â—� User program protection/password protection

Yes

Yes

  • â—� Copy protection

Yes

Yes

  • â—� Block protection

Yes

Yes

Access protection

 

 

  • â—� Protection level: Write protection

Yes

Yes

  • â—� Protection level: Read/write protection

Yes

Yes

  • â—� Protection level: Complete protection

Yes

Yes

Cycle time monitoring

 

 

  • â—� lower limit

adjustable minimum cycle time

adjustable minimum cycle time

  • â—� upper limit

adjustable maximum cycle time

adjustable maximum cycle time

Open Development interfaces

 

 

  • â—� Size of ODK SO file, max.

3.8 Mbyte

3.8 Mbyte

Peripherals/Options

 

 

Peripherals

  • â—� SD card

Optionally for additional mass storage

Optionally for additional mass storage

Dimensions

 

 

Width

160 mm

160 mm

Height

117 mm

117 mm

Depth

75 mm

75 mm

Weights

 

 

Weight, approx.

0.83 kg

0.83 kg


Article number

6ES7677-2FA31-0EB0

6ES7677-2FA41-0FB0

CPU 1515SP PC F

CPU 1515SP PC F

General information

 

 

Product type designation

CPU 1515SP PC F

CPU 1515SP PC F

HW functional status

FS05

FS02

Firmware version

V2.1

V2.1

Engineering with

 

 

  • â—� STEP 7 TIA Portal configurable/integrated as of version

V14 SP1

V14 SP1

Installed software

 

 

  • â—� Visualization

No

No

  • â—� Control

S7-1500 Software Controller CPU 1505SP F

S7-1500 Software Controller CPU 1505SP F

Configuration control

 

 

via dataset

Yes

Yes

Control elements

 

 

Mode selector switch

1

1

Supply voltage

 

 

Type of supply voltage

24 V DC

24 V DC

permissible range, lower limit (DC)

19.2 V

19.2 V

permissible range, upper limit (DC)

28.8 V

28.8 V

Reverse polarity protection

Yes

Yes

Mains buffering

 

 

  • â—� Mains/voltage failure stored energy time

5 ms

5 ms

Input current

 

 

Current consumption (rated value)

1.5 A; Full processor load, incl. ET 200SP modules and using USB

1.5 A; Full processor load, incl. ET 200SP modules and using USB

Current consumption (in no-load operation), typ.

0.6 A

0.6 A

Inrush current, max.

4.7 A; Rated value

4.7 A; Rated value

Power

 

 

Active power input, max.

36 W; incl. ET 200SP modules and using USB

36 W; incl. ET 200SP modules and using USB

Infeed power to the backplane bus

8.75 W

8.75 W

Power loss

 

 

Power loss, typ.

15 W; without ET 200SP modules and without using USB

15 W; without ET 200SP modules and without using USB

Processor

 

 

Processor type

Dual-Core 1 GHz, AMD G Series APU T40E

Dual-Core 1 GHz, AMD G Series APU T40E

Memory

 

 

Type of memory

DDR3-SDRAM

DDR3-SDRAM

Main memory

4 GB RAM

4 GB RAM

Flash Disk

30 GB

30 GB

CFast memory card

Yes; 30 GB flash memory

Yes; 30 GB flash memory

SIMATIC memory card required

No

No

Work memory

 

 

  • â—� integrated (for program)

1.5 Mbyte

1.5 Mbyte

  • â—� integrated (for data)

5 Mbyte

5 Mbyte

  • â—� integrated (for CPU function library of CPU Runtime)

10 Mbyte

10 Mbyte

Load memory

 

 

  • â—� integrated (on PC mass storage)

320 Mbyte

320 Mbyte

Backup

 

 

  • â—� with UPS

Yes; all memory areas declared retentive

Yes; all memory areas declared retentive

  • â—� with non-volatile memory

Yes

Yes

CPU processing times

 

 

for bit operations, typ.

10 ns

10 ns

for word operations, typ.

12 ns

12 ns

for fixed point arithmetic, typ.

16 ns

16 ns

for floating point arithmetic, typ.

64 ns

64 ns

CPU-blocks

 

 

Number of elements (total)

6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements

6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements

DB

 

 

  • â—� Number, max.

5 999; Number range: 1 to 65535

5 999; Number range: 1 to 65535

  • â—� Size, max.

5 Mbyte

5 Mbyte

FB

 

 

  • â—� Number, max.

5 998; Number range: 1 to 65535

5 998; Number range: 1 to 65535

  • â—� Size, max.

512 kbyte

512 kbyte

FC

 

 

  • â—� Number, max.

5 999; Number range: 1 to 65535

5 999; Number range: 1 to 65535

  • â—� Size, max.

512 kbyte

512 kbyte

OB

 

 

  • â—� Size, max.

1 048 kbyte

512 kbyte

  • â—� Number of free cycle OBs

100

100

  • â—� Number of time alarm OBs

20

20

  • â—� Number of delay alarm OBs

20

20

  • â—� Number of cyclic interrupt OBs

20

20

  • â—� Number of process alarm OBs

50

50

  • â—� Number of DPV1 alarm OBs

3

3

  • â—� Number of isochronous mode OBs

1

1

  • â—� Number of technology synchronous alarm OBs

2

2

  • â—� Number of startup OBs

100

100

  • â—� Number of asynchronous error OBs

4

4

  • â—� Number of synchronous error OBs

2

2

  • â—� Number of diagnostic alarm OBs

1

1

Nesting depth

 

 

  • â—� per priority class

24; Up to 8 possible for F-blocks

24; Up to 8 possible for F-blocks

Counters, timers and their retentivity

 

 

S7 counter

 

 

  • â—� Number

2 048

2 048

Retentivity

 

 

  • — adjustable

Yes

Yes

IEC counter

 

 

  • â—� Number

Any (only limited by the main memory)

Any (only limited by the main memory)

Retentivity

 

 

  • — adjustable

Yes

Yes

S7 times

 

 

  • â—� Number

2 048

2 048

Retentivity

 

 

  • — adjustable

Yes

Yes

IEC timer

 

 

  • â—� Number

Any (only limited by the main memory)

Any (only limited by the main memory)

Retentivity

 

 

  • — adjustable

Yes

Yes

Data areas and their retentivity

 

 

Retentive data area (incl. timers, counters, flags), max.

410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes

410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes

Flag

 

 

  • â—� Number, max.

16 kbyte

16 kbyte

  • â—� Number of clock memories

8; 8 clock memory bits, grouped into one clock memory byte

8; 8 clock memory bits, grouped into one clock memory byte

Data blocks

 

 

  • â—� Retentivity adjustable

Yes

Yes

  • â—� Retentivity preset

No

No

Local data

 

 

  • â—� per priority class, max.

64 kbyte; max. 16 KB per block

64 kbyte; max. 16 KB per block

Address area

 

 

Number of IO modules

8 192

8 192

I/O address area

 

 

  • â—� Inputs

32 kbyte; All inputs are in the process image

32 kbyte; All inputs are in the process image

  • â—� Outputs

32 kbyte; All outputs are in the process image

32 kbyte; All outputs are in the process image

of which per assigned PC interface

 

 

  • — Inputs (volume)

8 kbyte

8 kbyte

  • — Outputs (volume)

8 kbyte

8 kbyte

Subprocess images

 

 

  • â—� Number of subprocess images, max.

32

32

Hardware configuration

 

 

Integrated power supply

Yes

Yes

Number of distributed IO systems

20

20

Number of DP masters

 

 

  • â—� Via CM

1

1

Rack

 

 

  • â—� Modules per rack, max.

64; CPU 1515SP PC + 64 modules + server module

64; CPU 1515SP PC + 64 modules + server module

  • â—� Number of lines, max.

1

1

PtP CM

 

 

  • â—� Number of PtP CMs

the number of connectable PtP CMs is only limited by the number of available slots

the number of connectable PtP CMs is only limited by the number of available slots

Time of day

 

 

Clock

 

 

  • â—� Type

Hardware clock

Hardware clock

  • â—� Hardware clock (real-time)

Yes; Resolution: 1 s

Yes; Resolution: 1 s

  • â—� Backup time

6 wk; At 40 °C ambient temperature, typically

6 wk; At 40 °C ambient temperature, typically

  • â—� Deviation per day, max.

10 s; Typ.: 2 s

10 s; Typ.: 2 s

Clock synchronization

 

 

  • â—� supported

Yes

Yes

  • â—� to DP, master

No

No

  • â—� on Ethernet via NTP

Yes

Yes

  • â—� on Windows clock, slave

Yes

Yes

Interfaces

 

 

Number of industrial Ethernet interfaces

2

2

Number of PROFINET interfaces

1

1

Number of PROFIBUS interfaces

1

1

Number of RS 485 interfaces

1; Via CM DP module

1; Via CM DP module

Number of USB interfaces

3; 3x USB 2.0 on the front, 500 mA each – of which 2x 500 mA and 1x 100 mA simultaneously

3; 3x USB 2.0 on the front, 500 mA each – of which 2x 500 mA and 1x 100 mA simultaneously

Number of SD card slots

1

1

Video interfaces

 

 

  • â—� Graphics interface

1x DVI-I

1x DVI-I

1. Interface

 

 

Interface type

PROFINET

PROFINET

automatic detection of transmission rate

Yes

Yes

Autonegotiation

Yes

Yes

Autocrossing

Yes

Yes

Interface types

 

 

  • â—� Number of ports

2

2

  • â—� integrated switch

Yes

Yes

  • â—� RJ 45 (Ethernet)

Yes; Via BusAdapter BA 2x RJ45

Yes; Via BusAdapter BA 2x RJ45

  • — Transmission rate, max.

100 Mbit/s

100 Mbit/s

  • — Industrial Ethernet status LED

Yes

Yes

  • â—� BusAdapter (PROFINET)

Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC

Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC

Functionality

 

 

  • â—� Number of connections via this interface

88

88

  • â—� PROFINET IO Controller

Yes

Yes

  • â—� PROFINET IO Device

Yes

Yes

  • â—� SIMATIC communication

Yes

Yes

  • â—� Open IE communication

Yes

Yes

  • â—� Web server

Yes

Yes

PROFINET IO Controller

 

 

Services

 

 

  • — Isochronous mode

Yes

Yes

  • — shortest clock pulse

500 µs

500 µs

  • — IRT

Yes

Yes

  • — MRP

Yes

Yes

  • — MRPD

Yes

Yes

  • — Prioritized startup

Yes; Max. 32 PROFINET devices

Yes; Max. 32 PROFINET devices

  • — Number of connectable IO Devices, max.

128

128

  • — Of which IO devices with IRT, max.

64

64

  • — of which in line, max.

64

64

  • — Number of connectable IO Devices for RT, max.

128

128

  • — of which in line, max.

128

128

  • — Number of IO Devices that can be simultaneously activated/deactivated, max.

8

8

  • — IO Devices changing during operation (partner ports), supported

Yes

Yes

  • — Number of IO Devices per tool, max.

8

8

  • — Updating times

The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

Update time for IRT

 

 

  • — for send cycle of 500 µs

500 µs to 8 ms

500 µs to 8 ms

  • — for send cycle of 1 ms

1 ms to 16 ms

1 ms to 16 ms

  • — for send cycle of 2 ms

2 ms to 32 ms

2 ms to 32 ms

  • — for send cycle of 4 ms

4 ms to 64 ms

4 ms to 64 ms

  • — With IRT and parameterization of "odd" send cycles

Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)

Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)

Update time for RT

 

 

  • — for send cycle of 500 µs

500 µs to 256 ms

500 µs to 256 ms

  • — for send cycle of 1 ms

1 ms to 512 ms

1 ms to 512 ms

  • — for send cycle of 2 ms

2 ms to 512 ms

2 ms to 512 ms

  • — for send cycle of 4 ms

4 ms to 512 ms

4 ms to 512 ms

PROFINET IO Device

 

 

Services

 

 

  • — Isochronous mode

No

No

  • — IRT

Yes

Yes

  • — MRP

Yes

Yes

  • — MRPD

Yes

Yes

  • — Prioritized startup

Yes

Yes

  • — Shared device

Yes

Yes

  • — Number of IO Controllers with shared device, max.

4

4

2. Interface

 

 

Interface type

Integrated Ethernet interface

Integrated Ethernet interface

automatic detection of transmission rate

Yes

Yes

Autonegotiation

Yes

Yes

Autocrossing

Yes

Yes

Interface types

 

 

  • â—� Number of ports

1

1

  • â—� RJ 45 (Ethernet)

Yes; Integrated

Yes; Integrated

  • — Transmission rate, max.

1 000 Mbit/s

1 000 Mbit/s

  • — Industrial Ethernet status LED

No

No

3. Interface

 

 

Interface type

PROFIBUS with CM DP

PROFIBUS with CM DP

Interface types

 

 

  • â—� RS 485

Yes

Yes

Functionality

 

 

  • â—� Number of connections via this interface

44

44

  • â—� PROFIBUS DP master

Yes

Yes

  • â—� PROFIBUS DP slave

Yes

Yes

  • â—� SIMATIC communication

Yes

Yes

DP master

 

 

  • â—� Number of DP slaves, max.

125

125

Services

 

 

  • — Equidistance

No

No

  • — Isochronous mode

No

No

DP slave

 

 

Services

 

 

  • — Equidistance

No

No

  • — Isochronous mode

No

No

RS 485

 

 

  • â—� Transmission rate, max.

12 Mbit/s

12 Mbit/s

Protocols

 

 

Number of connections

 

 

  • â—� Number of connections, max.

88

88

  • â—� Number of connections reserved for ES/HMI/web

10

10

  • â—� Number of S7 routing paths

16

16

SIMATIC communication

 

 

  • â—� PG/OP communication

Yes

Yes

  • â—� S7 routing

Yes

Yes

  • â—� S7 communication, as server

Yes

Yes

  • â—� S7 communication, as client

Yes

Yes

  • â—� User data per job, max.

64 kbyte

64 kbyte

Open IE communication

 

 

  • â—� TCP/IP

Yes

Yes

  • — Data length, max.

64 kbyte

64 kbyte

  • â—� ISO-on-TCP (RFC1006)

Yes

Yes

  • — Data length, max.

64 kbyte

64 kbyte

  • â—� UDP

Yes

Yes

  • — Data length, max.

1 472 kbyte

1 472 kbyte

  • â—� SNMP

Yes

Yes

  • â—� DCP

Yes

Yes

  • â—� LLDP

Yes

Yes

Web server

 

 

  • â—� HTTP

Yes; Via Windows and PROFINET interface

Yes; Via Windows and PROFINET interface

  • â—� HTTPS

Yes; Only via PROFINET interface

Yes; Only via PROFINET interface

OPC UA

 

 

  • â—� OPC UA Client

No

  • â—� OPC UA Server

Data access (read, write, subscribe), runtime license required

Yes; Data access (read, write, subscribe), runtime license required

  • — Application authentication

Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

  • — Security policies

Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

  • — User authentication

"anonymous" or by user name & password

Yes; "anonymous" or by user name & password

Further protocols

 

 

  • â—� MODBUS

Yes; MODBUS TCP

Yes; MODBUS TCP

Media redundancy

 

 

  • â—� Switchover time on line break, typ.

200 ms

200 ms

  • â—� Number of stations in the ring, max.

50

50

S7 message functions

 

 

Number of login stations for message functions, max.

32

32

Program alarms

Yes

Yes

Number of configurable program alarms

10 000

10 000

Number of simultaneously active program alarms

  • â—� Number of program alarms

1 000

1 000

  • â—� Number of alarms for system diagnostics

200

200

  • â—� Number of alarms for motion technology objects

160

160

Test commissioning functions

 

 

Joint commission (Team Engineering)

Yes; Parallel online access possible for up to 8 engineering systems

Yes; Parallel online access possible for up to 8 engineering systems

Status block

Yes; up to 8 simultaneously

Yes; up to 8 simultaneously

Single step

No

No

Status/control

 

 

  • â—� Status/control variable

Yes

Yes

  • â—� Variables

Inputs, outputs, memory bits, DB, times, counters

Inputs, outputs, memory bits, DB, times, counters

  • â—� Number of variables, max.

  • — of which status variables, max.

200

200

  • — of which control variables, max.

200

200

Forcing

 

 

  • â—� Forcing

Yes

Yes

  • â—� Forcing, variables

Inputs, outputs

Inputs, outputs

  • â—� Number of variables, max.

200

200

Diagnostic buffer

 

 

  • â—� present

Yes

Yes

  • â—� Number of entries, max.

1 000

1 000

  • — of which powerfail-proof

300

300

Traces

 

 

  • â—� Number of configurable Traces

4

4

  • â—� Memory size per trace, max.

512 kbyte

512 kbyte

Interrupts/diagnostics/status information

 

 

Diagnostics indication LED

 

 

  • â—� RUN/STOP LED

Yes

Yes

  • â—� ERROR LED

Yes

Yes

  • â—� MAINT LED

Yes

Yes

Supported technology objects

 

 

Motion Control

Yes

Yes

  • â—� Number of available Motion Control resources for technology objects (except cam disks)

2 400

2 400

  • â—� Required Motion Control resources

  • — per speed-controlled axis

40; per axis

40; per axis

  • — per positioning axis

80; per axis

80; per axis

  • — per synchronous axis

160; per axis

160; per axis

  • — per external encoder

80; per external encoder

80; per external encoder

  • — per output cam

20; per cam

20; per cam

  • — per cam track

160; per cam track

160; per cam track

  • — per probe

40; per probe

40; per probe

  • â—� Positioning axis

  • — Number of positioning axes at motion control cycle of 4 ms (typical value)

5

5

  • — Number of positioning axes at motion control cycle of 8 ms (typical value)

12

12

Controller

  • â—� PID_Compact

Yes; Universal PID controller with integrated optimization

Yes; Universal PID controller with integrated optimization

  • â—� PID_3Step

Yes; PID controller with integrated optimization for valves

Yes; PID controller with integrated optimization for valves

  • â—� PID-Temp

Yes; PID controller with integrated optimization for temperature

Yes; PID controller with integrated optimization for temperature

Counting and measuring

  • â—� High-speed counter

Yes

Yes

EMC

 

 

Emission of radio interference acc. to EN 55 011

 

 

  • â—� Limit class A, for use in industrial areas

Yes

Yes

Standards, approvals, certificates

 

 

CE mark

Yes

Yes

CSA approval

Yes

Yes

cULus

Yes

Yes

FM approval

Yes

Yes

RCM (formerly C-TICK)

Yes

Yes

Highest safety class achievable in safety mode

 

 

Probability of failure (for service life of 20 years and repair time of 100 hours)

 

 

  • — Low demand mode: PFDavg in accordance with SIL3

< 2.00E-05

< 2.00E-05

  • — High demand/continuous mode: PFH in accordance with SIL3

< 1.00E-09 1/h

< 1.00E-09 1/h

Ambient conditions

 

 

Ambient temperature during operation

 

 

  • â—� min.

0 °C

0 °C

  • â—� max.

Up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load

Up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load

  • â—� horizontal installation, min.

0 °C

0 °C

  • â—� horizontal installation, max.

60 °C

60 °C

  • â—� vertical installation, min.

0 °C

0 °C

  • â—� vertical installation, max.

50 °C; With max. 32 ET 200SP modules and 3x 100 mA USB load

50 °C; With max. 32 ET 200SP modules and 3x 100 mA USB load

Ambient temperature during storage/transportation

 

 

  • â—� min.

-40 °C

-40 °C

  • â—� max.

70 °C

70 °C

Vibrations

 

 

  • â—� Operation, tested according to IEC 60068-2-6

Yes

Yes

  • â—� Transport, tested acc. to IEC 60068-2-6

Yes

Yes

Shock testing

 

 

  • â—� tested according to IEC 60068-2-6

Yes

Yes

  • â—� tested according to IEC 60068-2-27

Yes

Yes

  • â—� tested according to IEC 60068-2-29

Yes

Yes

  • â—� Storage/transport, tested acc. to IEC 60068-2-27

Yes

Yes

Operating systems

 

 

Operating systems

Windows Embedded Standard 7 E 32-bit

Windows Embedded Standard 7 P 64-bit

Configuration

 

 

Programming

 

 

Programming language

 

 

  • — LAD

Yes; incl. failsafe

Yes; incl. failsafe

  • — FBD

Yes; incl. failsafe

Yes; incl. failsafe

  • — STL

Yes

Yes

  • — SCL

Yes

Yes

  • — CFC

No

No

  • — GRAPH

Yes

Yes

Know-how protection

 

 

  • â—� User program protection/password protection

Yes

Yes

  • â—� Copy protection

Yes

Yes

  • â—� Block protection

Yes

Yes

Access protection

 

 

  • â—� Protection level: Write protection

Yes

Yes

  • â—� Protection level: Read/write protection

Yes

Yes

  • â—� Protection level: Complete protection

Yes

Yes

Cycle time monitoring

 

 

  • â—� lower limit

adjustable minimum cycle time

adjustable minimum cycle time

  • â—� upper limit

adjustable maximum cycle time

adjustable maximum cycle time

Open Development interfaces

 

 

  • â—� Size of ODK SO file, max.

3.8 Mbyte

3.8 Mbyte

Peripherals/Options

 

 

Peripherals

  • â—� SD card

Optionally for additional mass storage

Optionally for additional mass storage

Dimensions

 

 

Width

160 mm

160 mm

Height

117 mm

117 mm

Depth

75 mm

75 mm

Weights

 

 

Weight, approx.

0.83 kg

0.83 kg