|
| | | | | | |
The CPU 1512SP-1 PN CPU is snapped directly onto the standard mounting rail. It has: - A powerful processor:
The CPU achieves command execution times as low as 48 ns per binary instruction. - A large work memory:
200 KB for program, 1 MB for data - SIMATIC Memory Cards as load memory;
permitting additional functions such as firmware update, datalog and archives - Bit-modular expandability for maximum flexibility;
up to 64 I/O modules (I/O, technology, and communication modules) in any combination. Station width up to 1 m. - Mixed configuration with ET 200AL;
It is possible to integrate up to 16 I/O modules of the ET 200AL (IP65/IP67) I/O system in an installation of the scalable I/O system ET 200SP (IP20) via a "BU-Send" BaseUnit and a "BA-Send" BusAdapter. - PROFINET IO IRT interface with 3 integrated switch ports:
- Port 1 and 2 via BusAdapter
(The CPU 1512SP-1 PN is supplied without a BusAdapter and can also be operated without one. A suitable BusAdapter (BA 2xRJ45, BA 2xFC, BA 2xSCRJ, BA SCRJ/RJ45, BA SCRJ/FC, BA 2xLC, BA LC/RJ45 or BA LC/FC) can be ordered separately if required. - Port 3 integrated RJ45 socket
- Integrated communication functions:
- PG/OP communication
- PROFINET IO
- Open IE communication (TCP, ISO-on-TCP and UDP)
- OPC UA Server (Data Access)
- Web server
- S7 communication
- S7 routing
- Data set routing
- Maintenance-free data backup without battery
- Diagnostics displays for errors (Error), operation (RUN/Stop), maintenance (MT), power supply (PWR) and one link LED per port
- Optional labeling using light gray or yellow labeling strips. There is a choice of 2 materials:
- Foil and roll with 500 strips, for thermal transfer roll printer
- Paper (280 g/m2), DIN A4 sheets with 100 strips each, for laser printer
- The ET 200SP CPU can be equipped with a reference ID label
- Different PROFINET connection types by means of BusAdapter
- In standard applications with moderate mechanical and EMC loads, SIMATIC BusAdapters with an RJ45 interface can be used, e.g. BusAdapter BA 2xRJ45.
- For machines and systems in which higher mechanical and/or EMC loads act on the devices, a SIMATIC BusAdapter with connection via FastConnect (FC) or fiber-optic cable (SCRJ or LC) is recommended. Likewise, all SIMATIC BusAdapters with a fiber-optic cable connection (SCRJ, LC) can be used with the increased loads.
- BusAdapters with connections for fiber-optic cables can be used to cover high potential differences between two stations and/or high EMC loads.
- Dark BaseUnit as first BaseUnit behind the ET 200SP CPU when using an AC I/O module or an AI Energy Meter ST as the first I/O module
Scope of delivery: CPU 1512SP-1 PN including server module, 24 V DC connector and cover for BusAdapter port (BusAdapter must be ordered separately)
|
|