 If the drive output of a gantry with drive motors is distributed over multiple axes to achieve a more compact design and enhanced motion, these motors can be operated cost-optimized in parallel with a converter with an appropriate total power rating. The Motor Multi Connection Modules are used to protect the individual motors from the total power of the converter. Motor Multi Connection Modules contain the motor circuit breakers. Each motor circuit breaker protects one motor. Several motor circuit breakers are connected in parallel on the input side into a section for connection to a Motor Module. The Motor Multi Connection Modules can be equipped with optional analog measuring instruments built into the cabinet door for indicating the current motor currents and current output voltage of the Motor Modules.
|
|