General information | |
Product brand name | SIDOOR |
Product designation | Door controller |
Product version | ATD410W |
Optional product expansion | Mains transformer (6FB1112-0AT20-2TR0), NT40 (6FB1112-0AT20-3PS0), DIN rail holder (6FB1144-0AT00-3AS0) |
Manufacturer's article no. of the usable motor | 6FB1103-0AT11-3MC0, 6FB1103-0AT10-4MB0, 6FB1103-0AT10-3MC0, 6FB1103-0AT11-3MC0, 6FB1103-0AT14-3MC0, 6FB1103-0AT13-4MB0, 6FB1103-0AT14-4MB0, 6FB1103-0AT14-3MC0, 6FB1103-0AT13-3MC0, 6FB1103-0AT11-3MD0, 6FB1103-0AT10-3MD0 |
Manufacturer's article no. of the usable power supply unit | 6FB1112-0AT20-2TR0, 6FB1112-0AT20-3PS0, 6EP3446-8SB10-0AY0 |
Installation type/mounting | |
Installation and mounting instructions | No direct sunlight, requirements specific to the end application must be observed. NFPA industry environment: Installation outside a control cabinet only horizontal |
Supply voltage | |
Rated value (DC) | 36 V |
Input current | |
IІt, min. | 30 AІ·s |
Power | |
Active power input (standby mode) | 5 W |
Digital inputs | |
Control inputs isolated | Yes |
Control inputs p-switching | Yes |
Protection in case of DC supply | Use of a circuit breaker in the supply path according to 60898-1, 8A, C-characteristic type SIEMENS: 5SY4108-7 or 5SY4108-7KK11 |
Input voltage | |
| 10 V; Observe polarity ! |
| 28 V; Observe polarity ! |
Input current | |
| 9 mA |
| 27 mA |
Digital outputs | |
short-circuit proof | Yes |
Overload-proof | Yes |
Remark | Ensure correct polarity! CAUTION: Do not supply with external voltage! |
Output voltage | |
| 24 V |
Output current | |
| 400 mA |
Relay outputs | |
Switching capacity of contacts | |
| 0.01 A |
| 0.5 A |
Mechanical data | |
Opening width of door, min. | 0.3 m |
Opening width of door, max. | 5 m |
Weight of door, max. | 600 kg |
Operating cycle frequency of door, max. | 180 1/h |
Counterforce, max. | 75 N |
Kinetic energy, max. | 100 J |
Interfaces | |
Interfaces/bus type | USS according to EIA 485, IEC 61800-7-200 Type 3 |
Number of bus nodes | 32 |
Isolation | |
Overvoltage category | 2 |
Degree and class of protection | |
IP degree of protection | IP20 |
Standards, approvals, certificates | |
Certificate of suitability according to EN 81 | No |
CE mark | Yes |
UL approval | No |
EAC (formerly Gost-R) | Yes |
TГњV Inspectorate approval | Yes |
China RoHS compliance | Yes |
Standard for EMC | EN 61000-6-2 / EN 61000-6-4 |
Standard for safety | EN 60950-1 / EN ISO 13849-1 2008 Cat. 2 PL d |
Ambient conditions | |
Ambient temperature during operation | |
| -20 °C |
| 50 °C |
Ambient temperature during storage/transportation | |
| -40 °C |
| 70 °C |
Air pressure acc. to IEC 60068-2-13 | |
| 2 000 m |
Relative humidity | |
| 10 % |
| 93 % |
Dimensions | |
Width | 320 mm |
Height | 60 mm |
Depth | 80 mm |