PM240‑2 Power Modules, Standard variantPrinciple dimension drawing and drill pattern for PM240-2 Power Modules, Standard variant, with/without integrated line filter class A
1) Increased depth: • When the CU230P-2 Control Unit is plugged on, the depth increases by - 58 mm (2.28 in) for frame sizes FSA to FSC - 16 mm (0.63 in) for PM240-2 with frame sizes FSD to FSF • When the CU240E-2 Control Unit is plugged on, the depth increases by - 40 mm (1.57 in) for frame sizes FSA to FSC - 0 mm (0 in) for PM240-2 with frame sizes FSD to FSF • When the CU250S-2 Control Unit is plugged in, the depth increases - 61 mm (2.4 in) for frame sizes FSA to FSC - 19 mm (0.75 in) for PM240-2 with frame sizes FSD to FSF • When the IOP is plugged on, the depth increases by a further 22 mm (0.87 in) • When the BOP‑2 is plugged on, the depth increases by a further 12 mm (0.47 in) 2)The Power Modules can be mounted side by side. A side clearance of 1 mm (0.04 in) is recommended for tolerance-related reasons. PM240‑2 Power Modules, Push Through variantPrinciple dimension drawing and drill pattern for PM240-2 Power Modules, Push Through variant, with/without integrated line filter class A
1) Overall depth, of which 117.7 mm (4.63 in) is inside and 53.1 mm (2.09 in) is outside the control cabinet. Increased depth: • When the CU230P‑2 Control Unit is plugged on, the depth increases by 58 mm (2.28 in) • When the CU240E-2 Control Unit is plugged on, the depth increases by 40 mm (1.57 in) • When the CU250S-2 Control Unit is plugged on, the depth increases by 61 mm (2.4 in). • When the IOP is plugged on, the depth increases by a further 22 mm (0.87 in) • When the BOP‑2 is plugged on, the depth increases by a further 12 mm (0.47 in) 2) The Power Modules can be mounted side by side (mounting frame to mounting frame). A side clearance of 1 mm (0.04 in) is recommended for tolerance-related reasons. PM240 and PM250 Power Modules, IP20 degree of protectionPrinciple dimension drawing and drill pattern for PM240 and PM250 Power Modules, IP20 degree of protection, with/without integrated line filter class A
1) Increased depth: • When the CU230P-2 Control Unit is plugged on, the depth increases by - 58 mm (2.28 in) for frame size FSC - 49 mm (1.93 in) for frame sizes FSD to FSF • When the CU240E-2 Control Unit is plugged on, the depth increases by - 40 mm (1.57 in) for frame size FSC - 31 mm (1.22 in) for frame sizes FSD to FSF • When the CU250S-2 Control Unit is plugged in, the depth increases - 61 mm (2.4 in) for frame size FSC - 52 mm (2.05 in) for frame sizes FSD to FSF • When the IOP is plugged on, the depth increases by a further 22 mm (0.87 in) • When the BOP‑2 is plugged on, the depth increases by a further 12 mm (0.47 in) With the PM240 Power Module, frame size FSGX, the depth does not increase when devices are plugged on. 2) Up to 40 °C (104 °F) without any lateral clearance. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Каталог 2018 | Каталог 2017 | Каталог 2016 | Каталог 2015 | Каталог 2014 | Каталог 2013 | Каталог 2012 | Сертификат | Контакты | Карта сайта | Поиск |