The one-phase SIPLUS smart are the universal and powerful standard power supplies for machinery and plant engineering. Despite their compact design, they offer an excellent overload response: Thanks to a power boost of 150%, loads with high power consumption can be connected without any problems and the permanent overload capability of 120% offers power reserves in case of expansions. The high degree of efficiency results in low energy consumption and minimal heat generation inside the control cabinet. To further increase 24 V availability, the SIPLUS smart power supplies can be combined with buffer, DC UPS, redundancy and selectivity modules. Main product highlights- 1-phase, 24 V DC/10 A
- Input voltage 120 V and 230 V AC with automatic range switching
- Compact design - no lateral clearances required
- Extra power with 1.5 times the rated current (5 s/min) for brief, operational overload
- Permanent overload capability with 1.2 times the rated current up to 45 °C ambient temperature
- Adjustable output voltage for compensating voltage drops
- Signaling contact for easy integration in the plant monitoring system
- Wide temperature range from -25 or -10 to +70 °C
- Comprehensive certifications, such as cULus, ATEX and GL
Note:SIPLUS extreme products are based on Siemens standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added. SIPLUS PS PSU100S 24 V/10 A | | Article No. | 6AG1 334-2BA20-4AA0 | Article No. based on | 6EP1 334-2BA20 | Ambient temperature range | -25 ... +70 °C | Conformal coating | Coating of the printed circuit boards and the electronic components | Technical specifications | The technical specifications of the standard product apply, except for the ambient conditions. | Ambient conditions | Relative humidity | 100%, condensation/frost permitted. No commissioning in bedewed state. | Biologically active substances, compliance with EN 60721-3-3 | Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation. | Chemically active substances, compliance with EN 60721-3-3 | Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation. | Mechanically active substances, compliance with EN 60721-3-3 | Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation. | Air pressure (depending on the highest positive temperature range specified) | 1080 ... 795 hPa (-1 000 ... +2 000 m) see ambient temperature range 795 ... 658 hPa (+2 000 ... +3 500 m) derating 10 K 658 ... 540 hPa (+3 500 ... +5 000 m) derating 20 K |
Technical documentation on SIPLUS can be found here: http://www.siemens.de/siplus-extreme
|
|