Supply voltage | | | |
Load voltage L+ | | | |
| 24 V | | 24 to 48 V DC |
| No; external (e.g. automatic circuit breaker), tripping characteristic C | | No; external (e.g. automatic circuit breaker), tripping characteristic B, C |
| Yes | | Yes |
Input current | | | |
from load voltage L+ (without load), max. | 4 mA | | 12 mA |
Current carrying capacity | | | |
up to 60 °C, max. | 10 A | | 10 A |
Power loss | | | |
Power loss, typ. | 0.1 W | | 500 mW |
Power loss, max. | | 5 W | |
Interrupts/diagnostics/status information | | | |
Diagnostic messages | | | |
| Yes | | Yes |
Diagnostics indication LED | | | |
| Yes | | Yes |
| Yes | | Yes |
Parameter | | | |
Remark | 3 byte | | 3 byte |
Missing load voltage | Disable / enable | | Disable / enable |
Potential separation | | | |
primary/secondary | Yes; between rated load voltage and backplane bus, between power modules | | Yes; between rated load voltage and backplane bus, between power modules |
Isolation | | | |
Isolation tested with | 500 V DC | | 500 V DC |
Standards, approvals, certificates | | | |
CE mark | Yes | Yes | Yes |
UL approval | Yes | Yes | Yes |
Ambient conditions | | | |
Ambient temperature during operation | | | |
| -40 °C; = Tmin | -25 °C; = Tmin | -25 °C; = Tmin |
| 70 °C; = Tmax | 60 °C; = Tmax | 60 °C; = Tmax |
Altitude during operation relating to sea level | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | | | |
| 100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state) | 100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state) | 100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state) |
Resistance | | | |
Use in stationary industrial systems | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Dimensions | | | |
Width | 15 mm | 15 mm | 15 mm |
Height | 81 mm | 81 mm | 81 mm |
Depth | 52 mm | 52 mm | 52 mm |
Weights | | | |
Weight, approx. | 35 g | | 35 g |