Transmission rate | | |
Transfer rate | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s |
Interfaces for communication integrated | | |
Number of electrical connections | | |
| 16; RJ45 | 16; RJ45 |
| 8 | 8 |
Number of 100 Mbit/s ST(BFOC) ports | | |
| 8 | 8 |
Number of 100 Mbit/s SC ports | | |
| 8 | 8 |
Number of 1000 Mbit/s LC ports | | |
| 8 | 8 |
| 8 | 8 |
Interfaces others | | |
Number of electrical connections | | |
| 1 | 1 |
| 1 | 1 |
| 4 | 4 |
| 1 | 1 |
| 1 | 0 |
Type of electrical connection | | |
| RJ11 | RJ11 |
| 2-pole terminal block | 2-pole terminal block |
| 4-pole terminal block | 4-pole terminal block |
design of the removable storage | | |
| Yes | Yes |
Signal-Inputs/outputs | | |
Operating voltage of the signaling contacts | | |
| 24V | 24V |
Operating current of the signaling contacts | | |
| 0.1A | 0.1A |
Supply voltage, current consumption, power loss | | |
Type of voltage supply redundant power supply unit | No | No |
Type of voltage of the supply voltage | DC | DC |
Supply voltage | | |
| 24V | 24V |
| 19.2V | 19.2V |
| 28.8V | 28.8V |
Product component fusing at power supply input | Yes | Yes |
Fuse protection type at input for supply voltage | F 5 A / 250 V | F 5 A / 250 V |
Consumed current maximum | 4.2A | 4.2A |
Power loss [W] | | |
| 46W | 46W |
Permitted ambient conditions | | |
Ambient temperature | | |
| -40...+60C | -40...+70C |
| -40...+85C | -40...+85C |
| -40...+85C | -40...+85C |
| If the device is installed in the vertical position, the maximum operating temperature is reduced to 60 C. | If the device is installed in the vertical position, the maximum operating temperature is reduced to 60 C. |
Relative humidity | | |
| 95% | 95% |
Protection class IP | IP20 | IP20 |
Design, dimensions and weight | | |
Design | 19" rack | 19" rack |
Number of modular height units relating to 19-inch cabinet | 1 | 1 |
Width | 449mm | 449mm |
Height | 43.6mm | 43.6mm |
Depth | 305mm | 305mm |
Net weight | 6.8kg | 6.8kg |
Product feature conformal coating | | Yes |
Mounting type | When used in shipbuilding, the device must be secured in the 19" rack at four points | When used in shipbuilding, the device must be secured in the 19" rack at four points |
| Yes | Yes |
| No | No |
| No | No |
| No | No |
| No | No |
Product properties, functions, components general | | |
Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s | 100 | 100 |
Cascading in cases of star topology | any (depending only on signal propagation time) | any (depending only on signal propagation time) |
Product functions management, configuration | | |
Product function | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Protocol is supported | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Identification & maintenance function | | |
| Yes | Yes |
| Yes | Yes |
Product functions Diagnosis | | |
Product function | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Product functions VLAN | | |
Product function | | |
| Yes | Yes |
| No | No |
| No | No |
| Yes | Yes |
Number of VLANs maximum | 255 | 255 |
Number of VLANs - dynamic maximum | 255 | 255 |
Protocol is supported GVRP | Yes | Yes |
Product functions DHCP | | |
Product function | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Product functions Redundancy | | |
Product function | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Protocol is supported Media Redundancy Protocol (MRP) | Yes | Yes |
Product function | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | |
| No | |
| Yes | Yes |
Protocol is supported | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Product functions Security | | |
Product function | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Protocol is supported | | |
| Yes | Yes |
Product functions Time | | |
Product function | | |
| Yes | Yes |
Protocol is supported | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Standards, specifications, approvals | | |
Standard | | |
| FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
| EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
| UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 |
| UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 | UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
| EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) |
| EN 61000-6-2:2006 | EN 61000-6-2:2006 |
Standards, specifications, approvals CE | | |
Certificate of suitability CE marking | Yes | Yes |
Standards, specifications, approvals miscellaneous | | |
Certificate of suitability | EN 61000-6-2:2006, EN 61000-6-4:2007 | EN 61000-6-2:2006, EN 61000-6-4:2007 |
| Yes | Yes |
| | Yes |
| | Yes |
| No | No |
Standards, specifications, approvals ship classification | | |
Marine classification association | | |
| Yes | |
| Yes | |
| Yes | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
Standards, specifications, approvals product conformity | | |
MTBF at 40 C | 15y | |