Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6AG1222-1BF32-2XB0

6AG1222-1BF32-4XB0

6AG1222-1BH32-2XB0

6AG1222-1BH32-4XB0

SIPLUS S7-1200 SM 1222 8DQ

SIPLUS S7-1200 SM 1222 8DQ

SIPLUS S7-1200 SM 1222 16DQ

SIPLUS S7-1200 SM 1222 16DQ

Supply voltage

permissible range, lower limit (DC)

20.4V

20.4V

20.4V

20.4V

permissible range, upper limit (DC)

28.8V

28.8V

28.8V

28.8V

Input current

from backplane bus 5 V DC, max.

120mA

120mA

140mA

140mA

Power loss

Power loss, typ.

1.5W

1.5W

2.5W

2.5W

Digital outputs

Number of digital outputs

8

8

16

16

  • in groups of

1

1

1

1

Short-circuit protection

No; to be provided externally

No; to be provided externally

No; to be provided externally

No; to be provided externally

Limitation of inductive shutdown voltage to

typ. (L+) -48 V

typ. (L+) -48 V

typ. (L+) -48 V

typ. (L+) -48 V

Switching capacity of the outputs

  • with resistive load, max.

0.5A

0.5A

0.5A

0.5A

  • on lamp load, max.

5W

5W

5W

5W

Output voltage

  • Rated value (DC)

24V

24V

24V

24V

  • for signal "0", max.

0.1V; with 10 kOhm load

0.1V; with 10 kOhm load

0.1V; with 10 kOhm load

0.1V; with 10 kOhm load

  • for signal "1", min.

20 V DC

20 V DC

20 V DC

20 V DC

Output current

  • for signal "1" rated value

0.5A

0.5A

0.5A

0.5A

  • for signal "0" residual current, max.

10A

10A

10A

10A

Output delay with resistive load

  • "0" to "1", max.

50s

50s

50s

50s

  • "1" to "0", max.

200s

200s

200s

200s

Total current of the outputs (per group)

horizontal installation

  • up to 50 C, max.

4A; Current per mass

4A; Current per mass

8A; Current per mass

8A; Current per mass

Relay outputs

Switching capacity of contacts

  • with inductive load, max.

0.5A

0.5A

0.5A

0.5A

  • on lamp load, max.

5W

5W

5W

5W

  • with resistive load, max.

0.5A

0.5A

0.5A

0.5A

Cable length

  • shielded, max.

500m

500m

500m

500m

  • unshielded, max.

150m

150m

150m

150m

Interrupts/diagnostics/status information

Alarms

Yes

Yes

Yes

Yes

Diagnostic functions

Yes

Yes

Yes

Yes

Alarms

  • Diagnostic alarm

Yes

Yes

Yes

Yes

Diagnostic messages

  • Monitoring the supply voltage

Yes

Yes

Yes

Yes

Diagnostics indication LED

  • for status of the outputs

Yes

Yes

Yes

Yes

  • for maintenance

Yes

Yes

Yes

Yes

Potential separation

Potential separation digital outputs

  • between the channels, in groups of

1

1

1

1

  • between the channels and backplane bus

500 V AC

500 V AC

500 V AC

500 V AC

Degree and class of protection

Degree of protection acc. to EN 60529

  • IP20

Yes

Yes

Yes

Yes

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

Yes

Ambient conditions

Free fall

  • Fall height, max.

0.3m; five times, in product package

0.3m; five times, in product package

0.3m; five times, in product package

0.3m; five times, in product package

Ambient temperature during operation

  • min.

-40C; = Tmin; Startup @ -25 C

-20C; = Tmin; Startup @ 0 C

-40C; = Tmin; Startup @ -25 C

-20C; = Tmin; Startup @ 0 C

  • max.

70C; = Tmax; Tmax > +60 C number of simultaneously activated outputs 4 (no adjacent points) for horizontal mounting position

60C; = Tmax

70C; = Tmax; Tmax > +60 C number of simultaneously activated outputs 8 (no adjacent points) for horizontal mounting position

60C; = Tmax

Ambient temperature during storage/transportation

  • min.

-40C

-40C

-40C

-40C

  • max.

70C

70C

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Connection method

required front connector

Yes

Yes

Yes

Yes

Mechanics/material

Enclosure material (front)

  • Plastic

Yes

Yes

Yes

Yes

Dimensions

Width

45mm

45mm

45mm

45mm

Height

100mm

100mm

100mm

100mm

Depth

75mm

75mm

75mm

75mm

Weights

Weight, approx.

180g

180g

220g

220g


Article number

6AG1222-1HF32-2XB0

6AG1222-1HF32-4XB0

6AG1222-1HH32-2XB0

6AG1222-1HH32-4XB0

SIPLUS S7-1200 SM 1222 8DQ RLY

SIPLUS S7-1200 SM 1222 8DQ RLY

SIPLUS S7-1200 SM 1222 16DQ RLY

SIPLUS S7-1200 SM 1222 16DQ RLY

Supply voltage

permissible range, lower limit (DC)

20.4V

20.4V

20.4V

20.4V

permissible range, upper limit (DC)

28.8V

28.8V

28.8V

28.8V

Input current

from backplane bus 5 V DC, max.

120mA

120mA

135mA

135mA

Digital outputs

  • from load voltage L+, max.

11 mA/relay coil

11 mA/relay coil

11 mA/relay coil

11 mA/relay coil

Power loss

Power loss, typ.

4.5W

4.5W

8.5W

8.5W

Digital outputs

Number of digital outputs

8

8

16

16

  • in groups of

2

2

1

1

Short-circuit protection

No; to be provided externally

No; to be provided externally

No; to be provided externally

No; to be provided externally

Switching capacity of the outputs

  • with resistive load, max.

2A

2A

2A

2A

  • on lamp load, max.

30 W with DC, 200 W with AC

30 W with DC, 200 W with AC

30 W with DC, 200 W with AC

30 W with DC, 200 W with AC

Output voltage

  • Rated value (DC)

5 V DC to 30 V DC

5 V DC to 30 V DC

5 V DC to 30 V DC

5 V DC to 30 V DC

  • Rated value (AC)

5 V AC to 250 V AC

5 V AC to 250 V AC

5 V AC to 250 V AC

5 V AC to 250 V AC

Output current

  • for signal "1" rated value

2A

2A

2A

2A

Output delay with resistive load

  • "0" to "1", max.

10ms

10ms

10ms

10ms

  • "1" to "0", max.

10ms

10ms

10ms

10ms

Total current of the outputs (per group)

horizontal installation

  • up to 50 C, max.

10A; Current per mass

10A; Current per mass

10A; Current per mass

10A; Current per mass

Relay outputs

  • Number of relay outputs

8

8

16

16

  • Rated supply voltage of relay coil L+ (DC)

24V

24V

24V

24V

  • Number of operating cycles, max.

mechanically 10 million, at rated load voltage 100 000

mechanically 10 million, at rated load voltage 100 000

mechanically 10 million, at rated load voltage 100 000

mechanically 10 million, at rated load voltage 100 000

Switching capacity of contacts

  • with inductive load, max.

2A

2A

2A

2A

  • on lamp load, max.

30 W with DC, 200 W with AC

30 W with DC, 200 W with AC

30 W with DC, 200 W with AC

30 W with DC, 200 W with AC

  • with resistive load, max.

2A

2A

2A

2A

Cable length

  • shielded, max.

500m

500m

500m

500m

  • unshielded, max.

150m

150m

150m

150m

Interrupts/diagnostics/status information

Alarms

Yes

Yes

Yes

Yes

Diagnostic functions

Yes

Yes

Yes

Yes

Alarms

  • Diagnostic alarm

Yes

Yes

Yes

Yes

Diagnostic messages

  • Monitoring the supply voltage

Yes

Yes

Yes

Yes

Diagnostics indication LED

  • for status of the outputs

Yes

Yes

Yes

Yes

  • for maintenance

Yes

Yes

Yes

Yes

Potential separation

Potential separation digital outputs

  • between the channels

Relay, dry contact

Relay, dry contact

Relays

Relay, dry contact

  • between the channels, in groups of

2

2

4

4

  • between the channels and backplane bus

1500 V AC for 1 minute

1500 V AC for 1 minute

1500 V AC for 1 minute

1500 V AC for 1 minute

Permissible potential difference

between different circuits

750 V AC for 1 minute

750 V AC for 1 minute

750 V AC for 1 minute

750 V AC for 1 minute

Degree and class of protection

Degree of protection acc. to EN 60529

  • IP20

Yes

Yes

Yes

Yes

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

Yes

Ambient conditions

Free fall

  • Fall height, max.

0.3m; five times, in product package

0.3m; five times, in product package

0.3m; five times, in product package

0.3m; five times, in product package

Ambient temperature during operation

  • min.

-40C; = Tmin; Startup @ -25 C

-20C; = Tmin; Startup @ 0 C

-40C; = Tmin; Startup @ -25 C

-20C; = Tmin; Startup @ 0 C

  • max.

70C; = Tmax; Tmax > +60 C number of simultaneously activated outputs 4 (no adjacent points) for horizontal mounting position

60C; = Tmax

70C; = Tmax; Tmax > +60 C number of simultaneously activated outputs 8 (no adjacent points) for horizontal mounting position

60C; = Tmax

  • permissible temperature change

5C to 55C, 3C / minute

  • At cold restart, min.

-25C

Ambient temperature during storage/transportation

  • min.

-40C

-40C

-40C

-40C

  • max.

70C

70C

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); from 2 000 m max. 132 V AC

Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); from 2 000 m max. 132 V AC

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Connection method

required front connector

Yes

Yes

Yes

Yes

Mechanics/material

Enclosure material (front)

  • Plastic

Yes

Yes

Yes

Yes

Dimensions

Width

45mm

45mm

45mm

45mm

Height

100mm

100mm

100mm

100mm

Depth

75mm

75mm

75mm

75mm

Weights

Weight, approx.

190g

190g

260g

260g


















2018
Siemens Industry Catalog Drive technology Automation technology Automation systems SIMATIC Industrial Automation Systems Controllers LOGO! logic module Basic Controllers S7-1200 Central processing units I/O modules Digital modules SM 1221 digital input modules SB 1221 digital input modules SM 1222 digital output modules SB 1222 digital output modules SM 1223 digital input/output modules SB 1223 digital input/output modules SIPLUS digital modules SIPLUS SM 1221 digital input modules SIPLUS SB 1221 digital input modules SIPLUS SM 1222 digital output modules SIPLUS SB 1222 digital output modules SIPLUS SM 1223 digital input/output modules SIPLUS SB 1223 digital input/output modules Analog modules Special modules Communication Fail-safe digital inputs and outputs SIPLUS Fail-safe digital inputs and outputs Power supplies Operator control and monitoring Add-on products from third-party manufacturers Software Advanced Controllers Distributed Controllers Software Controllers Supplementary components I/O systems SIMATIC control systems Software for SIMATIC Controllers Programming devices Siemens Partner Programm SIMOTION Motion Control System SINUMERIK CNC automation systems System cabling/control cabinets Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.