Possible applications | |
| | |
| | |
| | |
Model | Bending beam load cell |
Loads | |
Rated load Emax | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
Minimum initial loading Emin | 0% Emax |
Maximum working load Lu | 150% Emax |
Ultimate load Ld | 300% Emax |
Safe lateral load LIq | 100% Emax |
Measurement characteristic values | |
Rated measuring path hn at Emax | 0.3 mm (0.01 in) |
Rated characteristic value Cn | 2.0 ± 0.02% mV/V |
Tolerance DO of zero signal | < ± 1.0% Cn |
Maximum load cell verification interval nLC | 3 0001) |
Min. load cell verification interval Vmin | Emax/15 000 |
Minimum application range Rmin(LC) | 20% |
Combined error Fcomb | ≤ 0.02% Cn |
Repeatability Fv | ≤ 0.017% Cn |
Creep error Fcr | |
30 min | ≤ ± 0.02% Cn |
Temperature effect | |
| ≤ ± 0.017% Cn/5K |
| ≤ ± 0.014% Cn/5K |
Electrical characteristic values | |
Recommended reference voltage Uref | 5 ... 10 V DC |
Input resistance Re | 460 О© ± 50 О© |
Output resistance Ra | 350 О© ± 3.5 О© |
Insulation resistance Ris | 5 000 MО© at 50 V DC |
Current calibration | Standard |
Connection and environmental conditions | |
Sensor material (DIN) | Stainless steel |
Max. tightening torque of the fixing screws | |
- Emax = 10, 20, 50,100, 200 kg (22.05, 44.09, 110.23, 220.46, 440.92 lb)
| 23 Nm2) |
- Emax = 350, 500 kg (771.62, 1102.31 lb)
| 70 Nm2) |
Function | Color |
| green |
| black |
- SIG + (measured signal +)
| white |
- SIG - (measured signal -)
| red |
| transparent |
Rated temperature range Btn | -10 ... +40 °C (14 ... 104 °F) |
Operating temperature range Btu | -35 ... +65 °C (-31 ... +149 °F) |
Storage temperature range Bts | -35 ... +65 °C (-31 ... +149 °F) |
Degree of protection according to EN 60529; IEC 60529 | IP68 |
Certificates and approvals | |
Accuracy class according to OIML R60 | C3 |