Article number

6ES7157-0AG81-0XA0

6ES7655-5DX40-2AA0

6ES7655-5DX40-1AA1

6ES7157-0AG82-0XA0

ACTIVE FIELD DISTRIBUTOR AFD4

ACTIVE FIELD DISTRIBUTOR AFD4 RAILMOUNT

ACTIVE FIELD DISTRIBUTOR AFD4 FM

ACTIVE FIELD DISTRIBUTOR AFD8

General information

 

 

 

 

Product type designation

Active Field Distributor AFD4

Active Field Distributor AFD4

Active Field Distributor AFD4 FM

Active Field Distributor AFD8

HW functional status

01

01

01

01

Product description

AFD4 FM

Product function

 

 

 

 

  • â—� Repeater function

No

No

No

No

Supply voltage

 

 

 

 

permissible range, lower limit (DC)

16 V

16 V

16 V

16 V

permissible range, upper limit (DC)

32 V

32 V

32 V

32 V

Reverse polarity protection

Yes; only in conjunction with FDC 157

Yes; only in conjunction with FDC 157

Overvoltage protection

No

No

Input current

 

 

 

 

Current consumption (in no-load operation), typ.

24 mA; 54 mA at the end of the cable

24 mA; 54 mA at the end of the cable

24 mA; 54 mA at the end of the cable

34 mA; 64 mA at the end of the cable

Current consumption, max.

264 mA

514 mA

Power loss

 

 

 

 

Power loss, typ.

384 mW

384 mW

384 mW

544 mW

Power loss, max.

3.2 W

3.2 W

3.2 W

4.1 W

Interfaces

 

 

 

 

PROFIBUS PA

 

 

 

 

  • â—� Transmission rate, max.

31.25 kbit/s

31.25 kbit/s

31.25 kbit/s

31.25 kbit/s

  • â—� Number of connectable PA field devices

4

4

4

8

  • â—� Current output to PA field devices, max.

240 mA

240 mA

240 mA

480 mA

  • â—� permissible current per spur line

60 mA

60 mA

60 mA

60 mA

Protocols

 

 

 

 

PROFIBUS DP

No

No

No

PROFIBUS PA

Yes

Yes

Yes

Yes

AS-Interface

No

No

No

FOUNDATION Fieldbus H1

Yes

Yes

Yes

Yes

Interrupts/diagnostics/status information

 

 

 

 

Status indicator

Yes

Yes

Yes

Yes

Alarms

No

No

No

No

Diagnostic functions

Yes

Yes

Yes

Yes

Diagnostics indication LED

 

 

 

 

  • â—� Main line status

Yes

Yes

Yes

Yes

  • â—� Main line failure

Yes

Yes

  • â—� Spur line status/fault

Yes

Yes

Yes

Yes

  • â—� automatic bus termination

Yes

Yes

Yes

Yes

Potential separation

 

 

 

 

between main line and spur lines

No

No

No

No

Degree and class of protection

 

 

 

 

Degree of protection acc. to EN 60529

  • â—� IP66

Yes

No

Yes

Yes

Standards, approvals, certificates

 

 

 

 

Use in hazardous areas

 

 

 

 

  • â—� ATEX Zone 1

No

No

No

No

  • â—� ATEX Zone 21

No

No

No

No

  • â—� ATEX Zone 2

Yes

Yes

Yes

Yes

  • â—� ATEX Zone 22

Yes

Yes

Yes

Yes

  • â—� FM Class I Zone 1

No

No

No

No

  • â—� FM Class I Zone 2, Division 2

Yes

Yes

Yes

Yes

Ambient conditions

 

 

 

 

Ambient temperature during operation

 

 

 

 

  • â—� min.

-40 °C

-40 °C

-40 °C

-40 °C

  • â—� max.

70 °C

70 °C

70 °C

70 °C

Ambient temperature during storage/transportation

 

 

 

 

  • â—� min.

-40 °C

-40 °C

-40 °C

-40 °C

  • â—� max.

85 °C

70 °C

85 °C

85 °C

Relative humidity

 

 

 

 

  • â—� Operation, max.

95 %

95 %

Connection method

 

 

 

 

Main line

 

 

 

 

  • â—� Number of main lines

2

2

2

2

  • â—� Design of terminals

Screw terminal block

Screw terminal block

Screw terminal block

Screw terminal block

  • â—� Type of connection (enclosure cable gland)

M16

M20

M16

  • â—� Type of cable

Type A

Type A

Type A

Type A

  • â—� Cable diameter, min.

4 mm

6 mm

4 mm

  • â—� Cable diameter, max.

9 mm

13 mm

9 mm

  • â—� Conductor cross-section, min.

0.2 mm²

0.2 mm²

0.2 mm²

0.2 mm²

  • â—� Conductor cross-section, max.

2.5 mm²

2.5 mm²

2.5 mm²

2.5 mm²

  • â—� automatic bus termination

Yes

Yes

Yes

Yes

  • â—� permissible main line current

1 A

1 A

1 A

1 A

Spur line

 

 

 

 

  • â—� Number of spur lines

4

4

4

8

  • â—� Design of terminals

Screw terminal block

Screw terminal block

Screw terminal block

  • â—� Type of connection (enclosure cable gland)

M16

M16

M16

  • â—� Type of cable

Type A

Type A

Type A

Type A

  • â—� Cable diameter, min.

4 mm

4 mm

4 mm

  • â—� Cable diameter, max.

9 mm

9 mm

9 mm

  • â—� Conductor cross-section, min.

0.2 mm²

0.2 mm²

0.2 mm²

0.2 mm²

  • â—� Conductor cross-section, max.

2.5 mm²

2.5 mm²

2.5 mm²

2.5 mm²

  • â—� total current output to field devices, max.

240 mA

240 mA

240 mA

480 mA

  • â—� Number of connectable field devices

4

4

4

8

  • â—� Current limitation per field device, max.

60 mA

60 mA

60 mA

60 mA

  • â—� No-load voltage, max.

30 V

30 V

  • â—� Short-circuit current (test current); max.

6 mA

6 mA

6 mA

6 mA

  • â—� intrinsically safe according to FISCO model

No

No

No

No

  • â—� Debounce logic

Yes

Yes

Yes

Yes

Dimensions

 

 

 

 

Width

220 mm

220 mm

220 mm

360 mm

Height

120 mm; without screw glands

120 mm

120 mm

120 mm; without screw glands

Depth

83 mm

83 mm

83 mm

83 mm

Weights

 

 

 

 

Weight, approx.

2 000 g

1 000 g

2 000 g

3 000 g


Article number

6ES7655-5DX60-1BB0

ACTIVE FIELD DISTRIBUTOR AFDISD

General information

 

Product type designation

AFDiSD active field distributor

HW functional status

01

Product description

Active field distributor with diagnostics

Product function

 

  • â—� Repeater function

Yes

Supply voltage

 

Design of the power supply

via fieldbus

permissible range, lower limit (DC)

16 V

permissible range, upper limit (DC)

32 V

Reverse polarity protection

Yes; only in conjunction with FDC 157

Overvoltage protection

Yes; only in conjunction with FDC 157

Input current

 

Current consumption, max.

400 mA; at 20 V input voltage

Current consumption in the case of short-circuit at all spur lines

100 mA; at 24 V input voltage

Power loss

 

Power loss, typ.

1.4 W; minimum - typ. specification not possible because load-dependent

Power loss, max.

5.9 W

Interfaces

 

PROFIBUS PA

 

  • â—� Transmission rate, max.

31.25 kbit/s

  • â—� Number of connectable PA field devices

6

  • â—� Current output to PA field devices, max.

260 mA; max. 180 mA total current of all field devices for operation in the permissible operating voltage range from 16 V to 32 V

  • â—� permissible current per spur line

40 mA; first spur line 60 mA

Protocols

 

PROFIBUS DP

No

PROFIBUS PA

Yes

AS-Interface

No

FOUNDATION Fieldbus H1

Yes

Interrupts/diagnostics/status information

 

Status indicator

Yes

Alarms

No

Diagnostic functions

Yes

Diagnostics indication LED

 

  • â—� Main line status

Yes

  • â—� Main line failure

Yes

  • â—� Spur line status/fault

Yes

  • â—� automatic bus termination

Yes

Potential separation

 

between main line and spur lines

Yes

Isolation

 

Isolation tested with

2 550 V DC

Degree and class of protection

 

Degree of protection acc. to EN 60529

  • â—� IP66

Yes

Standards, approvals, certificates

 

Use in hazardous areas

 

  • â—� ATEX Zone 1

Yes

  • â—� ATEX Zone 21

Yes

  • â—� ATEX Zone 2

Yes

  • â—� ATEX Zone 22

Yes

  • â—� FM Class I Zone 1

Yes

  • â—� FM Class I Zone 2, Division 2

Yes

  • â—� Type of protection acc. to KEMA

14 ATEX 0044

  • â—� Test number KEMA

14 ATEX 0044

Ambient conditions

 

Ambient temperature during operation

 

  • â—� min.

-40 °C

  • â—� max.

70 °C

Ambient temperature during storage/transportation

 

  • â—� min.

-40 °C

  • â—� max.

70 °C

Relative humidity

 

  • â—� Operation, max.

95 %

Connection method

 

Main line

 

  • â—� Number of main lines

2

  • â—� Design of terminals

Screw terminal block

  • â—� Type of connection (enclosure cable gland)

M20

  • â—� Type of cable

Type A

  • â—� Cable diameter, min.

6 mm

  • â—� Cable diameter, max.

13 mm

  • â—� Conductor cross-section, min.

0.2 mm²

  • â—� Conductor cross-section, max.

2.5 mm²

  • â—� automatic bus termination

Yes

  • â—� permissible main line current

1 A

Spur line

 

  • â—� Number of spur lines

6

  • â—� Design of terminals

Screw terminal block

  • â—� Type of connection (enclosure cable gland)

M16

  • â—� Type of cable

Type A

  • â—� Cable diameter, min.

4 mm

  • â—� Cable diameter, max.

9 mm

  • â—� Conductor cross-section, min.

0.2 mm²

  • â—� Conductor cross-section, max.

2.5 mm²

  • â—� total current output to field devices, max.

260 mA; max. 180 mA total current of all field devices for operation in the permissible operating voltage range from 16 V to 32 V

  • â—� Number of connectable field devices

6

  • â—� Current limitation per field device, max.

40 mA; 60 mA on S1

  • â—� No-load voltage, max.

15.3 V

  • â—� short-circuit proof

Yes

  • â—� Short-circuit current (test current); max.

6 mA

  • â—� intrinsically safe according to FISCO model

Yes

  • â—� Debounce logic

Yes

Dimensions

 

Width

380 mm

Height

85 mm

Depth

170 mm

Weights

 

Weight, approx.

4 500 g