Diagnostics | 1 | Factory data | X | X | X | X |
2 | Diagnostics values | X | X | — | X |
3 | Logbook | X | X | — | X |
4 | Display measuring ranges | X | X | — | X |
Calibration | 20 | Zero calibration | X | X | — | X |
21 | Sensitivity calibration | X | X | — | X |
22 | Zero point/sensitivity setpoints | X | X | — | X |
23 | Total/individual calibration | X | X | — | X |
24 | AUTOCAL | X | X | X | X |
25 | Drift values | X | X | — | — |
26 | Calibration with air (OXYMAT 64 only) | X | — | — | — |
Measuring ranges (Code 1) | 40 | Select measuring ranges | X | X | — | X |
41 | Define measuring ranges | X | X | — | X |
Parameter (code 1) | 50 | Electrical time constants | X | X | — | X |
51 | Limit values | X | X | — | — |
52 | On/off functions | X | — | — | X |
53 | Status messages | X | X | — | — |
54 | Graphical measured value representation | X | X | — | — |
55 | Measured-value display | X | X | — | — |
56 | LCD contrast | X | — | — | — |
57 | Chopper frequency (ULTRAMAT 6 only) Magnetic field frequency (OXYMAT 6 only) Flame ignition (FIDAMAT 6 only) | X | X | — | X |
58 | Date/time | X | X | — | X |
59 | Measuring point switchover | X | X | — | — |
60 | Logbook settings | X | — | — | X |
61 | Vibration compensation (OXYMAT 6 only) Switch internal valves (FIDAMAT 6 only) | X | X | — | X |
62 | Set external pressure (FIDAMAT 6 "without pump" only) | X | X | — | X |
Configuration (code 2) | 70 | Analog output | X | X | — | — |
71 | Relay assignment | X | X | — | X |
72 | Digital inputs | X | X | — | X |
73 | ELAN configuration | X | X | — | — |
74 | Reset | X | X | — | X |
75 | Save/load data | X | X | — | X |
76 | Suppression of short noise signals | X | X | — | X |
77 | Measured value memory (analog output) | X | X | — | — |
78 | Calibration tolerances | X | X | — | X |
79 | Change codes | X | X | — | — |
80 | Unit test | X | X | — | — |
81 | Language selection | X | X | — | — |
82 | Pressure correction (ULTRAMAT 6, OXYMAT 6, OXYMAT 64 and CALOMAT 62 only) | X | X | — | — |
83 | Correction of cross-interference | X | X | — | — |
84 | Phase calibration (ULTRAMAT 6 and OXYMAT 6 only) | X | — | — | — |
85 | Switch valves | X | — | — | — |
86 | Linear temperature compensation | X | X | — | — |
87 | Fault on/off | X | — | — | — |
88 | AK configuration (ULTRAMAT 6 and OXYMAT 6 only) | X | — | — | — |
89 | Sample chamber heating (ULTRAMAT 6, OXYMAT 6 and CALOMAT 62 only) | X | X | — | — |
90 | PROFIBUS configuration | X | X | X | X |
91 | Startup state (FIDAMAT 6 only) | X | X | — | — |
92 | Pressure values (FIDAMAT 6 only) | X | X | — | — |
93 | Units (FIDAMAT 6 only) | X | — | — | — |
|
| — | Control of external valves | — | — | — | X |
— | Software download | — | X | — | — |