Order code | Description |
|---|
Q30 | Clamping element5) | - One-piece for plug-on shaft
| - Two-piece for hollow shaft
| T32 | Stator torque arm4) 5) |
 Terminal box, max. connectable conductor cross-sectionsTerminal box | Cable entry | Outer cable diameter, max.1) | Number of main terminals | Cross-section per terminal, max. | Rated current, max.2) |
|---|
Type | Power | External signals | | | | | | | | | mm (in) | | mm2 | A | gk230 | 2 Г— M32 Г— 1.5 | 1 Г— M16 Г— 1.53) | 16 (0.63) | Phases: 3 Г— M5 Grounding: 1 Г— M4 | 2 Г— 16 | 50 | gk420 | 2 Г— M40 Г— 1.5 | 1 Г— M16 Г— 1.53) | 35 (1.38) | Phases: 3 Г— M10 Grounding: 1 Г— M6 | 2 Г— 35 | 105 | gk630 | 2 Г— M50 Г— 1.5 | 2 Г— M16 Г— 1.53) | 50 (1.97) | Phases: 3 Г— M10 Grounding: 1 Г— M10 | 2 Г— 50 | 260 | 1XB7700 | 3 Г— M75 Г— 1.5 | 2 Г— M16 Г— 1.53) | 120 (4.72) | Phases: 3 Г— M12 Grounding: 1 Г— M12 | 3 Г— 120 | 450 | 1XB7712 | 4 Г— M75 Г— 1.5 | 4 Г— PG 13.5 1 Г— M20 Г— 1.5 1 Г— M25 Г— 1.53) | 120 (4.72) | Phases: 3 Г— M16 Grounding: 1 Г— M16 | 4 Г— 120 | 800 |
1) Dependent on the design of the metric gland. 2) Current-carrying capacity based on EN 60204-1 and IEC 60364-5-52 for installation type C. 3) For option A11 or 9th data position "W" (without encoder). 4) Depending on motor type. Enquire regarding availability. 5) Not for solid shaft.
|
|