Article number

6AG1314-1AG14-2AY0

6AG1314-1AG14-7AB0

SIPLUS CPU314 EN50155

SIPLUS S7-300 CPU314

General information

HW functional status

01

01

Firmware version

V3.3

V3.3

Engineering with

  • Programming package

STEP 7 V5.5 + SP1 or higher or STEP 7 V5.2 + SP1 or higher with HSP 218

STEP 7 V5.5 + SP1 or higher or STEP 7 V5.2 + SP1 or higher with HSP 218

Supply voltage

Rated value (DC)

  • 24 V DC

Yes; A power supply according to EN 50155 shall be used

Yes

permissible range, lower limit (DC)

19.2V

19.2V

permissible range, upper limit (DC)

28.8V

28.8V

external protection for power supply lines (recommendation)

2 A min.

2 A min.

Mains buffering

  • Mains/voltage failure stored energy time

5ms

5ms

  • Repeat rate, min.

1s

1s

Input current

Current consumption (rated value)

650mA

650mA

Current consumption (in no-load operation), typ.

140mA

140mA

Inrush current, typ.

3.5A

3.5A

It

1As

1As

Power loss

Power loss, typ.

4W

4W

Memory

Work memory

  • integrated

128kbyte

128kbyte

  • expandable

No

No

  • Size of retentive memory for retentive data blocks

64kbyte

64kbyte

Load memory

  • Plug-in (MMC)

Yes

Yes

  • Plug-in (MMC), max.

8Mbyte

8Mbyte

  • Data management on MMC (after last programming), min.

10y

10y

Backup

  • present

Yes; Guaranteed by MMC (maintenance-free)

Yes; Guaranteed by MMC (maintenance-free)

  • without battery

Yes; Program and data

Yes; Program and data

CPU processing times

for bit operations, typ.

0.06s

0.06s

for word operations, typ.

0.12s

0.12s

for fixed point arithmetic, typ.

0.16s

0.16s

for floating point arithmetic, typ.

0.59s

0.59s

CPU-blocks

Number of blocks (total)

1024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

1024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

DB

  • Number, max.

1024; Number range: 1 to 16000

1024; Number range: 1 to 16000

  • Size, max.

64kbyte

64kbyte

FB

  • Number, max.

1024; Number range: 0 to 7999

1024; Number range: 0 to 7999

  • Size, max.

64kbyte

64kbyte

FC

  • Number, max.

1024; Number range: 0 to 7999

1024; Number range: 0 to 7999

  • Size, max.

64kbyte

64kbyte

OB

  • Description

see instruction list

see instruction list

  • Size, max.

64kbyte

64kbyte

  • Number of free cycle OBs

1; OB 1

1; OB 1

  • Number of time alarm OBs

1; OB 10

1; OB 10

  • Number of delay alarm OBs

2; OB 20, 21

2; OB 20, 21

  • Number of cyclic interrupt OBs

4; OB 32, 33, 34, 35

4; OB 32, 33, 34, 35

  • Number of process alarm OBs

1; OB 40

1; OB 40

  • Number of startup OBs

1; OB 100

1; OB 100

  • Number of asynchronous error OBs

4; OB 80, 82, 85, 87

4; OB 80, 82, 85, 87

  • Number of synchronous error OBs

2; OB 121, 122

2; OB 121, 122

Nesting depth

  • per priority class

16

16

  • additional within an error OB

4

4

Counters, timers and their retentivity

S7 counter

  • Number

256

256

Retentivity

  • adjustable

Yes

Yes

  • lower limit

0

0

  • upper limit

255

255

  • preset

Z 0 to Z 7

Z 0 to Z 7

Counting range

  • can be set

Yes

  • lower limit

0

0

  • upper limit

999

999

IEC counter

  • Number

Unlimited (limited only by RAM capacity)

Unlimited (limited only by RAM capacity)

S7 times

  • Number

256

256

Retentivity

  • adjustable

Yes

Yes

  • lower limit

0

0

  • upper limit

255

255

  • preset

No retentivity

No retentivity

Time range

  • lower limit

10ms

10ms

  • upper limit

9990s

9990s

IEC timer

  • present

Yes

Yes

  • Type

SFB

SFB

  • Number

Unlimited (limited only by RAM capacity)

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

retentive data area in total

All, max. 64 KB

All, max. 64 KB

Flag

  • Number, max.

256byte

256byte

  • Retentivity available

Yes; MB 0 to MB 255

Yes; MB 0 to MB 255

  • Retentivity preset

MB 0 to MB 15

MB 0 to MB 15

  • Number of clock memories

8; 1 memory byte

8; 1 memory byte

Data blocks

  • Retentivity adjustable

Yes; via non-retain property on DB

Yes; via non-retain property on DB

  • Retentivity preset

Yes

Yes

Local data

  • per priority class, max.

32kbyte; Max. 2 KB per block

32kbyte; Max. 2 KB per block

Address area

I/O address area

  • Inputs

1024byte

1024byte

  • Outputs

1024byte

1024byte

Process image

  • Inputs

1024byte

1024byte

  • Outputs

1024byte

1024byte

  • Inputs, adjustable

1024byte

1024byte

  • Outputs, adjustable

1024byte

1024byte

  • Inputs, default

128byte

128byte

  • Outputs, default

128byte

128byte

Digital channels

  • Inputs

1024

1024

  • of which central

1024

1024

  • Outputs

1024

1024

  • of which central

1024

1024

Analog channels

  • Inputs

256

256

  • of which central

256

256

  • Outputs

256

256

  • of which central

256

256

Hardware configuration

Number of expansion units, max.

3

3

Number of DP masters

  • integrated

0

0

  • via CP

4

4

Number of operable FMs and CPs (recommended)

  • FM

8

8

  • CP, PtP

8

8

  • CP, LAN

10

10

Rack

  • Racks, max.

4

4

  • Modules per rack, max.

8

8

Time of day

Clock

  • Hardware clock (real-time)

Yes

Yes

  • retentive and synchronizable

Yes

Yes

  • Backup time

6wk; At 40 C ambient temperature

6wk; At 40 C ambient temperature

  • Deviation per day, max.

10s; Typ.: 2 s

10s; Typ.: 2 s

  • Behavior of the clock following POWER-ON

Clock continues running after POWER OFF

Clock continues running after POWER OFF

  • Behavior of the clock following expiry of backup period

Clock continues to run with the time at which the power failure occurred

Clock continues to run with the time at which the power failure occurred

Operating hours counter

  • Number

1

1

  • Number/Number range

0

0

  • Range of values

0 to 2^31 hours (when using SFC 101)

0 to 2^31 hours (when using SFC 101)

  • Granularity

1 hour

1 hour

  • retentive

Yes; Must be restarted at each restart

Yes; Must be restarted at each restart

Clock synchronization

  • supported

Yes

Yes

  • to MPI, master

Yes

Yes

  • to MPI, slave

Yes

Yes

  • in AS, master

Yes

Yes

  • in AS, slave

No

No

Digital inputs

Number of digital inputs

0

0

Digital outputs

Number of digital outputs

0

0

Analog inputs

Number of analog inputs

0

0

Analog outputs

Number of analog outputs

0

0

Interfaces

Number of industrial Ethernet interfaces

0

0

Number of PROFINET interfaces

0

0

Number of RS 485 interfaces

1; MPI

1; MPI

Number of RS 422 interfaces

0

0

1. Interface

Interface type

Integrated RS 485 interface

Integrated RS 485 interface

Physics

RS 485

RS 485

Isolated

No

No

Power supply to interface (15 to 30 V DC), max.

200mA

200mA

Functionality

  • MPI

Yes

Yes

  • PROFIBUS DP master

No

No

  • PROFIBUS DP slave

No

No

  • Point-to-point connection

No

No

MPI

  • Transmission rate, max.

187.5kbit/s

187.5kbit/s

Services

  • PG/OP communication

Yes

Yes

  • Routing

No

No

  • Global data communication

Yes

Yes

  • S7 basic communication

Yes

Yes

  • S7 communication

Yes; Only server, configured on one side

Yes; Only server, configured on one side

  • S7 communication, as client

No

No

  • S7 communication, as server

Yes

Yes

Communication functions

PG/OP communication

Yes

Yes

Data record routing

No

No

Global data communication

  • supported

Yes

Yes

  • Number of GD loops, max.

8

8

  • Number of GD packets, max.

8

8

  • Number of GD packets, transmitter, max.

8

8

  • Number of GD packets, receiver, max.

8

8

  • Size of GD packets, max.

22byte

22byte

  • Size of GD packet (of which consistent), max.

22byte

22byte

S7 basic communication

  • supported

Yes

Yes

  • User data per job, max.

76byte

76byte

  • User data per job (of which consistent), max.

76byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

76byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

S7 communication

  • supported

Yes

Yes

  • as server

Yes

Yes

  • as client

Yes; Via CP and loadable FB

Yes; Via CP and loadable FB

  • User data per job, max.

180byte; With PUT/GET

180byte; With PUT/GET

  • User data per job (of which consistent), max.

240byte; as server

240byte; as server

S5 compatible communication

  • supported

Yes; via CP and loadable FC

Yes; via CP and loadable FC

Number of connections

  • overall

12

12

  • usable for PG communication

11

11

  • reserved for PG communication

1

1

  • adjustable for PG communication, min.

1

1

  • adjustable for PG communication, max.

11

11

  • usable for OP communication

11

11

  • reserved for OP communication

1

1

  • adjustable for OP communication, min.

1

1

  • adjustable for OP communication, max.

11

11

  • usable for S7 basic communication

8

8

  • reserved for S7 basic communication

0

0

  • adjustable for S7 basic communication, min.

0

0

  • adjustable for S7 basic communication, max.

8

8

S7 message functions

Number of login stations for message functions, max.

12; Depending on the configured connections for PG/OP and S7 basic communication

12; Depending on the configured connections for PG/OP and S7 basic communication

Process diagnostic messages

Yes

Yes

simultaneously active Alarm-S blocks, max.

300

300

Test commissioning functions

Status block

Yes; Up to 2 simultaneously

Yes; Up to 2 simultaneously

Single step

Yes

Yes

Number of breakpoints

4

4

Status/control

  • Status/control variable

Yes

Yes

  • Variables

Inputs, outputs, memory bits, DB, times, counters

Inputs, outputs, memory bits, DB, times, counters

  • Number of variables, max.

30

30

  • of which status variables, max.

30

30

  • of which control variables, max.

14

14

Forcing

  • Forcing

Yes

Yes

  • Forcing, variables

Inputs, outputs

Inputs, outputs

  • Number of variables, max.

10

10

Diagnostic buffer

  • present

Yes

Yes

  • Number of entries, max.

500

500

  • adjustable

No

No

  • of which powerfail-proof

100; Only the last 100 entries are retained

100; Only the last 100 entries are retained

  • Number of entries readable in RUN, max.

499

  • can be set

Yes; From 10 to 499

Yes; From 10 to 499

  • preset

10

10

Service data

  • can be read out

Yes

Standards, approvals, certificates

CE mark

Yes

Yes

UL approval

Yes

Yes; File E239877

FM approval

Yes

Yes; CofC 3028431

RCM (formerly C-TICK)

Yes

Yes

KC approval

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Railway application

  • EN 50155

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Use in hazardous areas

  • ATEX

Yes

Yes

Ambient conditions

Ambient temperature during operation

  • min.

-25C; = Tmin

-25C; = Tmin

  • max.

60C; = Tmax; the rated temperature range of -25 ... +55 C (T1) applies for the use on railway vehicles according to EN50155

70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use

Ambient temperature during storage/transportation

  • min.

-40C

-40C

  • max.

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Configuration

Configuration software

  • STEP 7

Yes; V5.2 SP1 or higher with HW update

Yes; V5.2 SP1 or higher with HW update

Programming

  • Command set

see instruction list

see instruction list

  • Nesting levels

8

8

  • System functions (SFC)

see instruction list

see instruction list

  • System function blocks (SFB)

see instruction list

see instruction list

Programming language

  • LAD

Yes

Yes

  • FBD

Yes

Yes

  • STL

Yes

Yes

  • SCL

Yes

Yes

  • CFC

Yes

Yes

  • GRAPH

Yes

Yes

  • HiGraph

Yes

Yes

Know-how protection

  • User program protection/password protection

Yes

Yes

  • Block encryption

Yes; With S7 block Privacy

Yes; With S7 block Privacy

Dimensions

Width

40mm

40mm

Height

125mm

125mm

Depth

130mm

130mm

Weights

Weight, approx.

280g

280g