Article number | 6AG1055-1CB00-7BA2 | 6AG1055-1HB00-7BA2 | 6AG1055-1MB00-7BA2 |
|---|
| SIPLUS LOGO! DM8 24 V8 | SIPLUS LOGO! DM8 24R V8 | SIPLUS LOGO! DM8 12/24R V8 |
|---|
Installation type/mounting | | | | Mounting | on 35 mm DIN rail, 2 spacing units wide | on 35 mm DIN rail, 2 spacing units wide | on 35 mm DIN rail, 2 spacing units wide | Supply voltage | | | | Rated value (DC) | | | | | | | Yes | | Yes | Yes | Yes | permissible range, lower limit (DC) | 20.4V | 20.4V | 10.8V | permissible range, upper limit (DC) | 28.8V | 28.8V | 28.8V | Rated value (AC) | | | | | | Yes | | Line frequency | | | | | | 47Hz | | | | 63Hz | | Digital inputs | | | | Number of digital inputs | 4 | 4 | 4 | Input voltage | | | | | DC | AC/DC | DC | | < 5 V DC | < 5 V AC/DC | < 5 V DC | | > 12 V DC | > 12 V AC/DC | > 8.5 V | Input current | | | | | 0.88mA | 1.1mA | 0.88mA | | 4mA | 5.5mA | 4.2mA | Input delay (for rated value of input voltage) | | | | for standard inputs | | | | | 1.5ms | 1.5ms | 1.5ms | | 1.5ms | 15ms | 1.5ms | Digital outputs | | | | Number of digital outputs | 4 | 4; Relays | 4; Relays | Short-circuit protection | Yes | No | No | Controlling a digital input | | Yes | Yes | Switching capacity of the outputs | | | | | | 1000W | 1000W | Output current | | | | | 0.3A | 5A | 5A | | | 100mA | 100mA | Parallel switching of two outputs | | | | | No | No | No | Switching frequency | | | | | 10Hz | 2Hz | 2Hz | | 0.5Hz | 0.5Hz | 0.5Hz | | | 10Hz | 10Hz | Relay outputs | | | | Switching capacity of contacts | | | | | | 3A | 3A | | | 5A | 5A | | 0.3A | | | EMC | | | | Emission of radio interference acc. to EN 55 011 | | | | | Yes | Yes | Yes | Degree and class of protection | | | | Degree of protection acc. to EN 60529 | | | | | Yes | Yes | Yes | Standards, approvals, certificates | | | | CE mark | Yes | Yes | Yes | CSA approval | | No | | UL approval | | No | | FM approval | Yes | No | | developed in accordance with IEC 61131 | Yes | Yes | Yes | according to VDE 0631 | Yes | Yes | | Marine approval | Yes | No | Yes | Ambient conditions | | | | Ambient temperature during operation | | | | | -40C; = Tmin; Startup @ -25 C | -40C; = Tmin; Startup @ -25 C | -40C; = Tmin; Startup @ -25 C | | 70C; Tmax; Tmax > +55 C max. load 0.2 A per output | 70C; = Tmax; Tmax > +55 C max. load 3 A per relay or max. total current 10 A | 70C; = Tmax; Tmax > +55 C max. load 3 A per relay or max. total current 10 A | | -25C | -25C | -25C | Ambient temperature during storage/transportation | | | | | -40C | -40C | -40C | | 70C | 70C | 70C | Altitude during operation relating to sea level | | | | | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | | | Relative humidity | | | | | 100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | Use in stationary industrial systems | | | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Dimensions | | | | Width | 35.5mm | 35.5mm | 35.5mm | Height | 90mm | 90mm | 90mm | Depth | 58mm | 58mm | 58mm |
Article number | 6AG1055-1FB00-7BA2 | 6AG1055-1NB10-7BA2 |
|---|
| SIPLUS LOGO! DM8 230R V8 | SIPLUS LOGO! DM16 24R V8 |
|---|
Installation type/mounting | | | Mounting | on 35 mm DIN rail, 2 spacing units wide | on 35 mm DIN rail, 4 spacing units wide | Supply voltage | | | Rated value (DC) | | | | | Yes | | Yes | | | Yes | | permissible range, lower limit (DC) | 100V | 20.4V | permissible range, upper limit (DC) | 253V | 28.8V | Rated value (AC) | | | | | No | | Yes | | | Yes | | Line frequency | | | | 47Hz | | | 63Hz | | Digital inputs | | | Number of digital inputs | 4 | 8 | Input voltage | | | | AC/DC | DC | | < 40 V AC, < 30 V DC | < 5 V DC | | > 79 V AC, > 79 V DC | > 12 V DC | Input current | | | | 0.06mA; 0.05 mA with AC, 0.06 mA with DC | 0.85mA | | 0.37mA | 3.5mA | Input delay (for rated value of input voltage) | | | for standard inputs | | | | 40ms | 1.5ms | | 75ms | 1.5ms | Digital outputs | | | Number of digital outputs | 4; Relays | 8; Relays | Short-circuit protection | No | No | Controlling a digital input | Yes | Yes | Switching capacity of the outputs | | | | 1000W; 500 W at 115V AC | 1000W | Output current | | | | 5A | 5A | | 100mA | 100mA | Parallel switching of two outputs | | | | No | No | Switching frequency | | | | 2Hz | 2Hz | | 0.5Hz | 0.5Hz | | 10Hz | 10Hz | Relay outputs | | | Switching capacity of contacts | | | | 3A | 3A | | 5A | 5A | EMC | | | Emission of radio interference acc. to EN 55 011 | | | | Yes | Yes | Degree and class of protection | | | Degree of protection acc. to EN 60529 | | | | Yes | Yes | Standards, approvals, certificates | | | CE mark | Yes | Yes | CSA approval | No | | UL approval | No | | FM approval | No | | developed in accordance with IEC 61131 | Yes | Yes | according to VDE 0631 | Yes | Yes | Marine approval | No | Yes | Ambient conditions | | | Ambient temperature during operation | | | | -40C; = Tmin; Startup @ -25 C | -40C; = Tmin; Startup @ -25 C | | 70C; = Tmax; Tmax > +55 C max. load 3 A per relay or max. total current 10 A | 70C; = Tmax; Tmax > +55 C max. load 3 A per relay | | -25C | -25C | Ambient temperature during storage/transportation | | | | -40C | -40C | | 70C | 70C | Relative humidity | | | | 100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | Use in stationary industrial systems | | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Dimensions | | | Width | 35.5mm | 71.5mm | Height | 90mm | 90mm | Depth | 58mm | 58mm |
Article number | 6AG1055-1MA00-7BA2 |
|---|
| SIPLUS LOGO! AM2 V8 |
|---|
Installation type/mounting | | Mounting | on 35 mm DIN rail, 2 spacing units wide | Supply voltage | | Rated value (DC) | | | Yes; 10.8 V DC to 28.8 V DC | | Yes; 10.8 V DC to 28.8 V DC | Analog inputs | | Number of analog inputs | 2 | Input ranges | | | Yes | | Yes | | No | Input ranges (rated values), voltages | | | Yes | Input ranges (rated values), currents | | | Yes; 0 mA or 4 mA to 20 mA | Input ranges (rated values), resistance thermometer | | | No | EMC | | Emission of radio interference acc. to EN 55 011 | | | Yes | Degree and class of protection | | Degree of protection acc. to EN 60529 | | | Yes | Standards, approvals, certificates | | CE mark | Yes | CSA approval | No | UL approval | No | FM approval | No | developed in accordance with IEC 61131 | Yes | according to VDE 0631 | Yes | Marine approval | Yes | Ambient conditions | | Ambient temperature during operation | | | -40C; = Tmin; Startup @ -25 C | | 70C; = Tmax | | -25C | Ambient temperature during storage/transportation | | | -40C | | 70C | Altitude during operation relating to sea level | | | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Relative humidity | | | 100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | Use in stationary industrial systems | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Dimensions | | Width | 35.5mm | Height | 90mm | Depth | 58mm |
Article number | 6AG1055-1MM00-7BA2 |
|---|
| SIPLUS LOGO! AM2 AQ V8 |
|---|
Installation type/mounting | | Mounting | on 35 mm DIN rail, 2 spacing units wide | Supply voltage | | Rated value (DC) | | | No | | Yes | Analog outputs | | Number of analog outputs | 2 | Output ranges, voltage | | | Yes | Output ranges, current | | | Yes | | Yes | EMC | | Emission of radio interference acc. to EN 55 011 | | | Yes | Degree and class of protection | | Degree of protection acc. to EN 60529 | | | Yes | Standards, approvals, certificates | | CE mark | Yes | developed in accordance with IEC 61131 | Yes | according to VDE 0631 | Yes | Marine approval | Yes | Ambient conditions | | Ambient temperature during operation | | | -40C; = Tmin; Startup @ -25 C | | 70C; = Tmax | | -25C | Ambient temperature during storage/transportation | | | -40C | | 70C | Altitude during operation relating to sea level | | | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Relative humidity | | | 100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | Use in stationary industrial systems | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Dimensions | | Width | 35.5mm | Height | 90mm | Depth | 58mm |
Article number | 6AG1055-1CB00-2BY0 | 6AG1055-1PB00-2BY0 | 6AG1055-1HB00-2BY0 | 6AG1055-1MB00-2BY1 |
|---|
| SIPLUS LOGO! DM8 24 | SIPLUS LOGO! DM8 12/24 | SIPLUS LOGO! DM8 24R | SIPLUS LOGO! DM8 12/24R |
|---|
Installation type/mounting | | | | | Mounting | on 35 mm DIN rail, 2 spacing units wide | on 35 mm DIN rail, 2 spacing units wide | on 35 mm DIN rail, 2 spacing units wide | on 35 mm DIN rail, 2 spacing units wide | Supply voltage | | | | | Rated value (DC) | | | | | | | | | Yes | | Yes | Yes | Yes | Yes | permissible range, lower limit (DC) | 20.4V; 22 V @ >55 C | 10.8V; 11 V @ >55 C | 20.4V; 22 V @ >55 C | 10.8V; 11 V @ >55 C | permissible range, upper limit (DC) | 28.8V; 27.5 V @ >55 C | 28.8V; 27.5 V @ >55 C | 28.8V; 27.5 V @ >55 C | 28.8V; 27.5 V @ >55 C | Rated value (AC) | | | | | | | | Yes | | Digital inputs | | | | | Number of digital inputs | 4 | 4 | 4 | 4 | Input voltage | | | | | | DC | DC | AC/DC | DC | Digital outputs | | | | | Number of digital outputs | 4; Transistor | 4; Transistor | 4; Relays | 4; Relays | Short-circuit protection | Yes | Yes | No | No | Output current | | | | | | 0.3A; 0.2 A @ > 55 C; 0.3 A @ > 55 C & < 15 s | 0.3A; 0.2 A @ > 55 C; 0.3 A @ > 55 C & < 15 s | 5A | 5A | Relay outputs | | | | | Switching capacity of contacts | | | | | | | | 3A; 1 A per relay @ > 55 C; 3 A per relay @ > 55 C & < 15 s | 3A; 1 A per relay @ > 55 C; 3 A per relay @ > 55 C & < 15 s | | | | 5A; 3 A per relay @ > 55 C; 5 A < 15 s; 10 A all 4 relays in total | 5A; 3 A per relay @ > 55 C; 5 A < 15 s; 10 A all 4 relays in total | EMC | | | | | Emission of radio interference acc. to EN 55 011 | | | | | | Yes | Yes | Yes | Yes | Degree and class of protection | | | | | Degree of protection acc. to EN 60529 | | | | | | Yes | Yes | Yes | Yes | Standards, approvals, certificates | | | | | CSA approval | No | No | No | No | UL approval | Yes; File: E120869 // Tmax = 55 C | Yes; File: E120869 // Tmax = 55 C | Yes; File: E120869 // Tmax = 55 C | Yes; File: E120869 // Tmax = 55 C | FM approval | No | No | No | No | developed in accordance with IEC 61131 | Yes | Yes | Yes | Yes | according to VDE 0631 | Yes | Yes | Yes | Yes | Marine approval | No | No | No | No | Ambient conditions | | | | | Ambient temperature during operation | | | | | | -40C; = Tmin | -40C; = Tmin | -40C; = Tmin | -40C; = Tmin | | 70C; = Tmax; 55 C @ UL/cUL use | 70C; = Tmax; 55 C @ UL/cUL use | 70C; = Tmax; 55 C @ UL/cUL use | 70C; = Tmax; 55 C @ UL/cUL use | Altitude during operation relating to sea level | | | | | | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Relative humidity | | | | | | 100%; RH incl. condensation/frost permitted (no commissioning in bedewed state) | 100%; RH incl. condensation/frost permitted (no commissioning in bedewed state) | 100%; RH incl. condensation/frost permitted (no commissioning in bedewed state) | 100%; RH incl. condensation/frost permitted (no commissioning in bedewed state) | Use in stationary industrial systems | | | | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Dimensions | | | | | Width | 36mm; 2 DU | 36mm; 2 DU | 36mm; 2 DU | 36mm; 2 DU | Height | 90mm | 90mm | 90mm | 90mm | Depth | 55mm | 55mm | 55mm | 55mm |
Article number | 6AG1055-1FB00-2BY1 | 6AG1055-1NB10-2BA0 |
|---|
| SIPLUS LOGO! DM8 230R | SIPLUS LOGO! DM16 24R ERW.-MODUL |
|---|
Installation type/mounting | | | Mounting | on 35 mm DIN rail, 2 spacing units wide | on 35 mm DIN rail, 4 spacing units wide | Supply voltage | | | Rated value (DC) | | | | | Yes | | Yes | | | Yes | | permissible range, lower limit (DC) | 100V | 20.4V; 22 V @ >55 C | permissible range, upper limit (DC) | 253V | 28.8V; 27.5 V @ >55 C | Rated value (AC) | | | | Yes | | | Yes | | Digital inputs | | | Number of digital inputs | 4 | 8 | Input voltage | | | | AC/DC | DC | | | < 5 V DC | | | > 12 V DC | Input current | | | | | 1mA | | | 2mA | Input delay (for rated value of input voltage) | | | for standard inputs | | | | | 1.5ms | | | 1.5ms | Digital outputs | | | Number of digital outputs | 4; Relays | 8; Relays | Short-circuit protection | No | No | Controlling a digital input | | Yes | Switching capacity of the outputs | | | | | 1000W; 500 W at 115V AC | Output current | | | | 5A | 5A | Parallel switching of two outputs | | | | | No | Switching frequency | | | | | 2Hz | | | 0.5Hz | | | 10Hz | Relay outputs | | | Switching capacity of contacts | | | | 3A; 1 A per relay @ > 55 C; 3 A per relay @ > 55 C & < 15 s | 3A; 1 A per relay @ > 55 C; 3 A per relay @ > 55 C & < 15 s | | 5A; 3 A per relay @ > 55 C; 5 A < 15 s; 10 A all 4 relays in total | 5A; 3 A per relay @ > 55 C; 10 A per relay @ > 55 C & < 15 s | EMC | | | Emission of radio interference acc. to EN 55 011 | | | | Yes | Yes | Degree and class of protection | | | Degree of protection acc. to EN 60529 | | | | Yes | Yes | Standards, approvals, certificates | | | CSA approval | No | No | UL approval | Yes; File: E120869 // Tmax = 55 C | In application process | FM approval | No | No | developed in accordance with IEC 61131 | Yes | Yes | according to VDE 0631 | Yes | Yes | Marine approval | No | No | Ambient conditions | | | Ambient temperature during operation | | | | -40C; = Tmin | -25C; = Tmin | | 70C; = Tmax; 55 C @ UL/cUL use | 70C; = Tmax; 55 C @ UL/cUL use | Altitude during operation relating to sea level | | | | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Relative humidity | | | | 100%; RH incl. condensation/frost permitted (no commissioning in bedewed state) | 100%; RH incl. condensation/frost permitted (no commissioning in bedewed state) | Use in stationary industrial systems | | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Dimensions | | | Width | 36mm; 2 DU | 72mm; 4 WU | Height | 90mm | 90mm | Depth | 55mm | 53mm |
Article number | 6AG1055-1MA00-2BY0 |
|---|
| SIPLUS LOGO! AM2 |
|---|
Installation type/mounting | | Mounting | on 35 mm DIN rail, 2 spacing units wide | Supply voltage | | Rated value (DC) | | | Yes | | Yes | Analog inputs | | Number of analog inputs | 2 | Input ranges | | | Yes | | Yes | | No | Input ranges (rated values), voltages | | | Yes | Input ranges (rated values), currents | | | Yes | EMC | | Emission of radio interference acc. to EN 55 011 | | | Yes | Degree and class of protection | | Degree of protection acc. to EN 60529 | | | Yes | Standards, approvals, certificates | | CSA approval | No | UL approval | Yes; File: E120869 // Tmax = 55 C | FM approval | No | developed in accordance with IEC 61131 | Yes | according to VDE 0631 | Yes | Marine approval | No | Ambient conditions | | Ambient temperature during operation | | | -40C; = Tmin | | 70C; = Tmax; 55 C @ UL/cUL use | Altitude during operation relating to sea level | | | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Relative humidity | | | 100%; RH incl. condensation/frost permitted (no commissioning in bedewed state) | Use in stationary industrial systems | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Dimensions | | Width | 36mm | Height | 90mm | Depth | 55mm |
Article number | 6AG1055-1MM00-2BY1 |
|---|
| SIPLUS_LOGO!_AM2_AQ |
|---|
Installation type/mounting | | Mounting | on 35 mm DIN rail, 2 spacing units wide | Supply voltage | | Rated value (DC) | | | Yes | Analog outputs | | Number of analog outputs | 2 | Output ranges, voltage | | | Yes | Output ranges, current | | | Yes | | Yes | EMC | | Emission of radio interference acc. to EN 55 011 | | | Yes; Radio interference suppression according to EN55011, Limit Value Class B | Degree and class of protection | | Degree of protection acc. to EN 60529 | | | Yes | Standards, approvals, certificates | | CSA approval | No | UL approval | No | FM approval | No | developed in accordance with IEC 61131 | Yes | according to VDE 0631 | Yes | Marine approval | No | Ambient conditions | | Ambient temperature during operation | | | -40C; = Tmin | | 70C; = Tmax; 55 C @ UL/cUL use | Altitude during operation relating to sea level | | | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Relative humidity | | | 100%; RH incl. condensation/frost permitted (no commissioning in bedewed state) | Use in stationary industrial systems | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Dimensions | | Width | 36mm | Height | 90mm | Depth | 55mm |
|
|