Article number | 6GK5104-2BB00-2AA3 | 6GK5106-1BB00-2AA3 | 6GK5108-0BA00-2AA3 | 6GK5108-0PA00-2AA3 |
|---|
Transmission rate | | | | | Transfer rate | 10Mbit/s,100Mbit/s | 10Mbit/s,100Mbit/s | 10Mbit/s,100Mbit/s | 10Mbit/s,100Mbit/s | Interfaces for communication integrated | | | | | Number of electrical connections | | | | | | 4; RJ45 with securing collar | 6; RJ45 with securing collar | 8; RJ45 with securing collar | 6; RJ45 with securing collar | | | | | 2 | Number of 100 Mbit/s ST(BFOC) ports | | | | | | 2 | 1 | | | Number of 100 Mbit/s SC ports | | | | | | 0 | 0 | 0 | 0 | Number of 1000 Mbit/s LC ports | | | | | | 0 | 0 | 0 | 0 | | 0 | 0 | 0 | 0 | Interfaces others | | | | | Number of electrical connections | | | | | | 1 | 1 | 1 | 1 | | 1 | 1 | 1 | 1 | | 1 | 1 | 1 | 1 | Type of electrical connection | | | | | | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | | 4-pole terminal block | 4-pole terminal block | 4-pole terminal block | 4-pole terminal block | Signal-Inputs/outputs | | | | | Operating voltage of the signaling contacts | | | | | | 24V | 24V | 24V | 24V | Operating current of the signaling contacts | | | | | | 0.1A | 0.1A | 0.1A | 0.1A | Supply voltage, current consumption, power loss | | | | | Type of voltage of the supply voltage | DC | DC | DC | DC | Supply voltage | | | | | | 24V | 24V | 24V | 24V | | 18V | 18V | 18V | 18V | | 32V | 32V | 32V | 32V | Product component fusing at power supply input | Yes | Yes | Yes | Yes | Fuse protection type at input for supply voltage | 0.6 A / 60 V | 0.6 A / 60 V | 0.6 A / 60 V | 4 A / 125 V | Consumed current maximum | 0.16A | 0.15A | 0.14A | 1.7A | Power loss [W] | | | | | | 3.8W | 3.6W | 3.36W | 10W | Supplied active power of PSE with PoE | | | | | | | | | 15.4W | | | | | 30.8W | Permitted ambient conditions | | | | | Ambient temperature | | | | | | -10...+60C | -10...+60C | -20...+70C | -20...+60C | | -40...+80C | -40...+80C | -40...+80C | -40...+80C | | -40...+80C | -40...+80C | -40...+80C | -40...+80C | | | | | At 55 C ambient temperature on both sides 40 mm distance to adjacent devices | Relative humidity | | | | | | 95% | 95% | 95% | 95% | Protection class IP | IP30 | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | | Design | compact | compact | compact | compact | Width | 60mm | 60mm | 60mm | 60mm | Height | 125mm | 125mm | 125mm | 125mm | Depth | 124mm | 124mm | 124mm | 124mm | Net weight | 0.78kg | 0.78kg | 0.78kg | 0.9kg | Product feature conformal coating | | | | No | Mounting type | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | Product functions management, configuration | | | | | Product function | | | | | | No | No | No | No | | Yes | Yes | Yes | Yes | | No | No | No | No | Product functions Redundancy | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | No | No | No | No | Standards, specifications, approvals | | | | | Standard | | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4A, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class A) | EN 61000-6-4:2001 | | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2:2001 | Standards, specifications, approvals CE | | | | | Certificate of suitability CE marking | Yes | Yes | Yes | Yes | Standards, specifications, approvals miscellaneous | | | | | Certificate of suitability | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2:2001, EN 61000-6-4:2001 | | Yes | Yes | Yes | Yes | | | | Yes | No | | | | Yes | No | | | | No | Yes | | Yes | Yes | Yes | Yes | Standards, specifications, approvals ship classification | | | | | Marine classification association | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | No | | Yes | Yes | Yes | No | Standards, specifications, approvals product conformity | | | | | Product conformity | | | | | | | | | Yes | MTBF at 40 C | 134.87y | 136.65y | 139.83y | 61.64y |
Article number | 6GK5112-2BB00-2AA3 | 6GK5116-0BA00-2AA3 | 6GK5124-0BA00-2AA3 |
|---|
Transmission rate | | | | Transfer rate | 10Mbit/s,100Mbit/s | 10Mbit/s,100Mbit/s | 10Mbit/s,100Mbit/s | Interfaces for communication integrated | | | | Number of electrical connections | | | | | 12; RJ45 with securing collar | 16; RJ45 with securing collar | 24; RJ45 with securing collar | Number of 100 Mbit/s ST(BFOC) ports | | | | | 2 | | | Number of 100 Mbit/s SC ports | | | | | 0 | 0 | 0 | Number of 1000 Mbit/s LC ports | | | | | 0 | 0 | 0 | | 0 | 0 | 0 | Interfaces others | | | | Number of electrical connections | | | | | 1 | 1 | 1 | | 1 | 1 | 1 | | 1 | 1 | 1 | Type of electrical connection | | | | | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | | 4-pole terminal block | 4-pole terminal block | 4-pole terminal block | Signal-Inputs/outputs | | | | Operating voltage of the signaling contacts | | | | | 24V | 24V | 24V | Operating current of the signaling contacts | | | | | 0.1A | 0.1A | 0.1A | Supply voltage, current consumption, power loss | | | | Type of voltage of the supply voltage | DC | DC | DC | Supply voltage | | | | | 24V | 24V | 24V | | 18V | 18V | 18V | | 32V | 32V | 32V | Product component fusing at power supply input | No | No | No | Consumed current maximum | 0.45A | 0.3A | 0.45A | Power loss [W] | | | | | 5.16W | 4.4W | 4.8W | Permitted ambient conditions | | | | Ambient temperature | | | | | -10...+70C | -20...+70C | -20...+70C | | -40...+80C | -40...+80C | -40...+80C | | -40...+80C | -40...+80C | -40...+80C | Relative humidity | | | | | 95% | 95% | 95% | Protection class IP | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | Design | compact | compact | compact | Width | 120mm | 120mm | 180mm | Height | 125mm | 125mm | 125mm | Depth | 124mm | 124mm | 124mm | Net weight | 1.1kg | 1.1kg | 1.5kg | Mounting type | | | | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | No | No | No | Product functions management, configuration | | | | Product function | | | | | No | No | No | | Yes | Yes | Yes | | No | No | No | Product functions Redundancy | | | | Product function | | | | | Yes | Yes | Yes | | No | No | No | Standards, specifications, approvals | | | | Standard | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. | | EN 61000-6-4:2001 | EN 61000-6-4:2001 | EN 61000-6-4:2001 | | EN 61000-6-2:2001 | EN 61000-6-2:2001 | EN 61000-6-2:2001 | Standards, specifications, approvals CE | | | | Certificate of suitability CE marking | Yes | Yes | Yes | Standards, specifications, approvals miscellaneous | | | | Certificate of suitability | EN 61000-6-2:2001, EN 61000-6-4:2001 | EN 61000-6-2:2001, EN 61000-6-4:2001 | EN 61000-6-2:2001, EN 61000-6-4:2001 | | Yes | Yes | Yes | | Yes | Yes | Yes | Standards, specifications, approvals ship classification | | | | Marine classification association | | | | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | No | No | No | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | Standards, specifications, approvals product conformity | | | | MTBF at 40 C | 61.3y | 61.3y | 49.3y |
|
|