Machine type | Self-starting permanent magnet excited synchronous motor |
|---|
Magnet material | Rare-earth/ferrite magnet material | Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1) | Temperature class F for a winding temperature of up to 105 K at an ambient temperature of 40 °C | Operating voltage | Unrestricted operation on the mains or frequency converter according to rating plate | Standards and regulations | The motors comply with the appropriate standards and regulations, especially IEC 60034 | Type of construction | In accordance with EN 60034-7 (IEC 60034-7), see types of construction | Terminal box arrangement (view onto DE) | Top | Terminal box connection type | Terminals in the terminal box for motor connection and PTC thermistor | Degree of protection in accordance with EN 60034-5 (IEC 60034-5) | IP54 for 2-pole motors IP55 for 4-pole and 6-pole motors | Permissible ambient temperature | -20 °C to +40 °C | Cooling | Self-cooling | Temperature monitoring | Motor protection through PTC thermistor with 3 built-in temperature sensors for shutdown | Paint finish | RAL 7030, stone gray | Shaft end on the drive end in accordance with DIN 748-3 (IEC 60072-1) | Shaft end on the drive end with featherkey and featherkey way (half-key balancing) | Radial eccentricity, concentricity, and axial eccentricity in accordance with DIN 42955 (IEC 60072-1) | Tolerance N (normal) | Vibration severity in accordance with EN 60034-14 (IEC 60034-14) | Grade N (normal) | Options | - Vibration severity grade R or S
- Reduced radial eccentricity grade R
- Cast iron enclosure
- Location bearing DE or NDE
- Radial shaft sealing ring for gear attachment
- Metal fan
- Textile fan cover
- D-end bearings for increased cantilever forces
- Regreasing device
- Forced ventilation
- Terminal box located on left or right
- Modular built-on brake
- Gear attachment
- Connected modular frequency converter with or without gear
|
Structure of order number………1 F U 8 0 8 3 – 4 T A 3 1 – Z | |
|---|
Position 1 2 3 4 5 6 7 - 8 9 10 11 12 | | Position: assignment | | 1st to 4th position | SIEMOSYN 1FU8 motor | 5th and 6th position | Motor frame size, coded from 71M to 160L | 7th position | Length | 8th position (number) | Number of poles | 9th position | Ventilation | | | T = self-cooled | | | W = non ventilated | 10th position | Power range | | | A = power range 7 | | | B = power range 5 C = special application D = power range 7 for frame sizes 132 and 160 E = power range 5 for frame sizes 132 and 160 | 11th position | Voltage characteristic number/winding design 1 = 80 V/50 Hz 2 = 100 V/50 Hz 3 = 125 V/50 Hz 6 = 200 V/50 Hz 8 = 400 V/50 Hz | 12th position | Type of construction | Special versions: | | - Z | Special versions only in conjunction with order code and plaintext where applicable |
Order exampleThree-phase motor IP55, speed range 600 to 4800 min-1 M = constant = 5 Nm in the speed range Type of construction IM B5 Special version: - PTC thermistor for warning and shutdown
- Radial shaft sealing ring for gear installation
Order no. according to selection table | 1FU8 083-4TA3� (A11, standard) |
|---|
Type of construction IM B5 | 1 | Special version | -Z | PTC thermistor for warning and shutdown | A12 | Radial shaft sealing ring DE | K17 | Specify when ordering | 1FU8 083-4TA31-Z A12 + K17 |
1FU8 motors, 2-pole, 50 Hz/3000 min-1 M = constant for 20 to 250 Hz/1200 to 15000 min-1 M=constant for 20 Hz to fmax | Values at 50 Hz | Values at max. frequency | | | | |
|---|
Rated load torque | Rated power | Rated current | Inrush current | Rated power | Rated current | Inrush current | Frame size | Order no. | Max. external moment of inertia | Weight for type of construction IM B5 | MN | PN | IN | I1 | PN | IN | I1 | | | Jext | | Nm | kW | A | A | kW | A | A | | | kgm2 | approx. kg | max. frequency 50 Hz at UN = 400 V/50 Hz, max. speed 3000 min-1 | 1.3 | 0.41 | 2.0 | 7.3 | - | - | - | 80 | 1FU8 080 - 2TA8� | 0.023 | 9 | 2.2 | 0.7 | 2.9 | 11.8 | - | - | - | 80 | 1FU8 083 - 2TA8� | 0.035 | 11 | 2.9 | 0.9 | 3.8 | 17.5 | - | - | - | 80 | 1FU8 086 - 2TA8� | 0.045 | 12 | 7.3 | 2.3 | 6.8 | 43 | - | - | - | 112 | 1FU8 113 - 2TA8� | 0.3 | 29 | max. frequency 100 Hz at UN = 200 V/50 Hz, max. speed 6000 min-1 | 1.3 | 0.41 | 4.1 | 14.6 | 0.82 | 4.2 | 21.7 | 80 | 1FU8 080 - 2TA6� | 0.023 | 9 | 2.2 | 0.7 | 5.8 | 23.5 | 1.4 | 6.0 | 34.6 | 80 | 1FU8 083 - 2TA6� | 0.035 | 11 | 2.9 | 0.9 | 7.2 | 33 | 1.8 | 7.5 | 48 | 80 | 1FU8 086 - 2TA6� | 0.045 | 12 | 7.3 | 2.3 | 13.5 | 85 | 4.6 | 14.1 | 130 | 112 | 1FU8 113 - 2TA6� | 0.25 | 29 | max. frequency 160 Hz at UN = 125 V/50 Hz, max. speed 9600 min-1 | 1.3 | 0.41 | 5.5 | 18.8 | 1.31 | 5.8 | 33 | 80 | 1FU8 080 - 2TA3� | 0.023 | 12 | 2.2 | 0.7 | 8.5 | 30.6 | 2.24 | 9.1 | 52.4 | 80 | 1FU8 083 - 2TA3� | 0.035 | 14 | 2.9 | 0.9 | 13 | 58 | 2.92 | 13.5 | 100 | 80 | 1FU8 086 - 2TA3� | 0.045 | 15 | 7.3 | 2.3 | 22 | 140 | 7.3 | 24.5 | 240 | 112 | 1FU8 113 - 2TA3� | 0.2 | 35 | max. frequency 200 Hz at UN = 100 V/50 Hz, max. speed 12000 min-1 | 1.3 | 0.41 | 7.9 | 29.2 | 1.63 | 9.0 | 55.3 | 80 | 1FU8 080 - 2TA2� | 0.02 | 12 | 2.2 | 0.7 | 10.2 | 40.5 | 2.8 | 11.2 | 74 | 80 | 1FU8 083 - 2TA2� | 0.03 | 14 | 2.7 | 0.85 | 14.2 | 66.3 | 3.5 | 15.2 | 121 | 80 | 1FU8 086 - 2TA2� | 0.04 | 15 | 6.5 | 2,04 | 21 | 130 | 8.2 | 22 | 225 | 112 | 1FU8 113 - 2TA2� | 0.2 | 35 | max. frequency 250 Hz at UN = 80 V/50 Hz, max. speed 15000 min-1 | 1.3 | 0.41 | 9.0 | 33.6 | 2.04 | 11 | 66.6 | 80 | 1FU8 080 - 2TA1� | 0.017 | 12 | 2.2 | 0.7 | 13 | 44 | 3.46 | 14 | 83.5 | 80 | 1FU8 083 - 2TA1� | 0.025 | 14 | 2.4 | 0.75 | 14.5 | 83 | 3.8 | 16.7 | 140 | 80 | 1FU8 086 - 2TA1� | 0.033 | 15 |
When ordering options, an encrypted order code must additionally be specified for each design desired (plaintext where applicable). Order codes must not be repeated in plaintext. Order No.: 1FU8��� - �T��� - Z Order code(s) ��� +��� +��� 1FU8 motors, 4-pole, 50 Hz/1500 min-1 M = constant for 20 to 200 Hz/600 to 6000 min-1 M = constant for 20 Hz to fmax | Values at 50 Hz | Values at max. frequency | | | | |
|---|
Rated load torque | Rated power | Rated current | Inrush current | Rated power | Rated current | Inrush current | Frame size | Order no. | Max. external moment of inertia | Weight for type of construction IM B5 | MN | PN | IN | I1 | PN | IN | I1 | | | Jext | | Nm | kW | A | A | kW | A | A | | | kgm2 | approx. kg | max. frequency 50 Hz at UN = 400 V/50 Hz, max. speed 1500 min-1 | 2 | 0.31 | 0.7 | 2.4 | - | - | - | 71 | 1FU8 073 - 4TA8� | 0.006 | 6 | 2.6 | 0.41 | 0.9 | 3.2 | - | - | - | 71 | 1FU8 076 - 4TA8� | 0.008 | 7 | 3.5 | 0.55 | 1.2 | 3.9 | - | - | - | 80 | 1FU8 080 - 4TA8� | 0.007 | 9 | 5 | 0.79 | 1.7 | 5.7 | - | - | - | 80 | 1FU8 083 - 4TA8� | 0.01 | 10 | 7 | 1.1 | 2.3 | 9.2 | - | - | - | 80 | 1FU8 086 - 4TA8� | 0.013 | 12 | 8.5 | 1.33 | 3.1 | 14.3 | - | - | - | 90 | 1FU8 096 - 4TA8� | 0.07 | 16 | 9.7 | 1.52 | 3.2 | 15.8 | - | - | - | 90 | 1FU8 098 - 4TA8� | 0.08 | 18 | 18 | 2.83 | 6.7 | 33.7 | - | - | - | 112 | 1FU8 113 - 4TA8� | 0.15 | 31 | max. frequency 100 Hz at UN = 200 V/50 Hz, max. speed 3000 min-1 | 2 | 0.31 | 1.4 | 4.8 | 0.62 | 1.5 | 7.7 | 71 | 1FU8 073 - 4TA6� | 0.012 | 6 | 2.6 | 0.41 | 1.7 | 6.3 | 0.82 | 1.8 | 9.9 | 71 | 1FU8 076 - 4TA6� | 0.015 | 7 | 3.5 | 0.55 | 2.4 | 7.8 | 1.1 | 2.4 | 13 | 80 | 1FU8 080 - 4TA6� | 0.015 | 9 | 5 | 0.79 | 3.4 | 11.4 | 1.57 | 3.3 | 19 | 80 | 1FU8 083 - 4TA6� | 0.025 | 10 | 7 | 1.1 | 4.5 | 18.4 | 2.2 | 4.5 | 30.3 | 80 | 1FU8 086 - 4TA6� | 0.03 | 12 | 8.5 | 1.33 | 6.1 | 28.5 | 2.67 | 6.2 | 42.9 | 90 | 1FU8 096 - 4TA6� | 0.13 | 16 | 9.7 | 1.52 | 6.4 | 31.6 | 3.05 | 6.4 | 45.8 | 90 | 1FU8 098 - 4TA6� | 0.15 | 18 | 18 | 2.83 | 13.1 | 66.8 | 5.65 | 13.4 | 95.2 | 112 | 1FU8 113 - 4TA6� | 0.4 | 31 | max. frequency 160 Hz at UN = 125 V/50 Hz, max. speed 4800 min-1 | 2 | 0.31 | 2.2 | 8.2 | 1.0 | 2.5 | 17 | 71 | 1FU8 073 - 4TA3� | 0.012 | 6 | 2.6 | 0.41 | 2.7 | 10.0 | 1.31 | 2.9 | 19.7 | 71 | 1FU8 076 - 4TA3� | 0.015 | 7 | 3.5 | 0.55 | 3.8 | 12.2 | 1.76 | 3.8 | 26.5 | 80 | 1FU8 080 - 4TA3� | 0.015 | 9 | 5 | 0.79 | 5.3 | 19.3 | 2.51 | 5.3 | 42.3 | 80 | 1FU8 083 - 4TA3� | 0.025 | 10 | 7 | 1.1 | 7.2 | 29.4 | 3.52 | 7.2 | 63.8 | 80 | 1FU8 086 - 4TA3� | 0.03 | 12 | 8.5 | 1.33 | 9.7 | 50 | 4.27 | 10.0 | 93.3 | 90 | 1FU8 096 - 4TA3� | 0.15 | 16 | 9.7 | 1.52 | 10.3 | 52.3 | 4.88 | 10.3 | 90.5 | 90 | 1FU8 098 - 4TA3� | 0.18 | 18 | 18 | 2.83 | 22.4 | 117 | 9.05 | 23.5 | 211 | 112 | 1FU8 113 - 4TA3� | 0.4 | 31 | max. frequency 200 Hz at UN = 100 V/50 Hz, max. speed 6000 min-1 | 2 | 0.31 | 2.7 | 9.5 | 1.26 | 3.0 | 21.4 | 71 | 1FU8 073 - 4TA2� | 0.012 | 6 | 2.6 | 0.41 | 3.5 | 12.7 | 1.63 | 3.7 | 27.7 | 71 | 1FU8 076 - 4TA2� | 0.015 | 7 | 3.5 | 0.55 | 4.8 | 15.6 | 2.2 | 4.9 | 37.7 | 80 | 1FU8 080 - 4TA2� | 0.015 | 9 | 5 | 0.79 | 6.7 | 25 | 3.14 | 6.7 | 61.5 | 80 | 1FU8 083 - 4TA2� | 0.025 | 10 | 7 | 1.1 | 9.0 | 36.8 | 4.4 | 9.0 | 88.7 | 80 | 1FU8 086 - 4TA2� | 0.03 | 12 | 8.5 | 1.33 | 12.1 | 57 | 5.34 | 12.9 | 113 | 90 | 1FU8 096 - 4TA2� | 0.15 | 16 | 9.7 | 1.52 | 12.7 | 63.3 | 6.1 | 12.7 | 115 | 90 | 1FU8 098 - 4TA2� | 0.18 | 18 | 18 | 2.83 | 26.2 | 134 | 11.3 | 27.3 | 251 | 112 | 1FU8 113 - 4TA2� | 0.4 | 31 |
When ordering options, an encrypted order code must additionally be specified for each design desired (plaintext where applicable). Order codes must not be repeated in plaintext. Order No.: 1FU8 ��� - �T��� - Z Order code(s) ��� +��� +��� 1FU8 motors, 4-pole, 50 Hz/1500 min-1 M = constant for 13.3 to 200 Hz/400 to 6000 min-1 M = constant for 13.3 Hz to fmax | Values at 50 Hz | Values at max. frequency | | | | |
|---|
Rated load torque | Rated power | Rated current | Inrush current | Rated power | Rated current | Inrush current | Frame size | Order no. | Max. external moment of inertia | Weight for type of construction IM B5 | MN | PN | IN | I1 | PN | IN | I1 | | | Jext | | Nm | kW | A | A | kW | A | A | | | kgm2 | approx. kg | max. frequency 50 Hz at UN = 400 V/50 Hz, max. speed 1500 min-1 | 2.5 | 0.38 | 1.0 | 3.9 | - | - | - | 80 | 1FU8 080 - 4TA8� | 0.005 | 9 | 5.2 | 0.82 | 1.7 | 9.2 | - | - | - | 80 | 1FU8 086 - 4TA8� | 0.01 | 12 | 8 | 1.26 | 2.7 | 15.8 | - | - | - | 90 | 1FU8 098 - 4TA8� | 0.06 | 18 | 16 | 2.51 | 6.0 | 33.7 | - | - | - | 112 | 1FU8 113 - 4TA8� | 0.11 | 31 | max. frequency 100 Hz at UN = 200 V/50 Hz, max. speed 3000 min-1 | 2.5 | 0.38 | 2.0 | 7.8 | 0.79 | 2.0 | 13 | 80 | 1FU8 080 - 4TA6� | 0.011 | 9 | 5.2 | 0.82 | 3.4 | 18.4 | 1.63 | 3.4 | 30.3 | 80 | 1FU8 086 - 4TA6� | 0.022 | 12 | 8 | 1.26 | 5.5 | 31.6 | 2.51 | 5.5 | 45.8 | 90 | 1FU8 098 - 4TA6� | 0.11 | 18 | 16 | 2.51 | 12.0 | 66.8 | 5.03 | 12.3 | 95.2 | 112 | 1FU8 113 - 4TA6� | 0.33 | 31 | max. frequency 160 Hz at UN = 125 V/50 Hz, max. speed 4800 min-1 | 2.5 | 0.38 | 2.8 | 12.2 | 1.26 | 2.9 | 26.5 | 80 | 1FU8 080 - 4TA3� | 0.011 | 9 | 5.2 | 0.82 | 5.3 | 29.4 | 2.61 | 5.3 | 63.8 | 80 | 1FU8 086 - 4TA3� | 0.022 | 12 | 8 | 1.26 | 8.8 | 52.3 | 4.02 | 9.0 | 90.5 | 90 | 1FU8 098 - 4TA3� | 0.13 | 18 | 16 | 2.51 | 20.7 | 117 | 8.04 | 21.8 | 211 | 112 | 1FU8 113 - 4TA3� | 0.33 | 31 | max. frequency 200 Hz at UN = 100 V/50 Hz, max. speed 6000 min-1 | 2.5 | 0.38 | 4.1 | 15.6 | 1.57 | 4.1 | 37.7 | 80 | 1FU8 080 - 4TA2� | 0.011 | 9 | 5.2 | 0.82 | 6.7 | 36.8 | 3.27 | 6.8 | 88.7 | 80 | 1FU8 086 - 4TA2� | 0.022 | 12 | 8 | 1.26 | 10.9 | 63.3 | 5.03 | 11.1 | 115 | 90 | 1FU8 098 - 4TA2� | 0.13 | 18 | 16 | 2.51 | 23.9 | 134 | 10.1 | 25.1 | 251 | 112 | 1FU8 113 - 4TA2� | 0.33 | 31 |
When ordering options, an encrypted order code must additionally be specified for each design desired (plaintext where applicable). Order codes must not be repeated in plaintext. Order No.: 1FU8��� - �T��� - Z Order code(s) ��� +��� +��� 1FU8 motors, 6-pole, 50 Hz/1000 min-1 M = constant for 20 to 200 Hz/400 to 4000 min-1 M = constant for 20 Hz to fmax | Values at 50 Hz | Values at max. frequency | | | | |
|---|
Rated load torque | Rated power | Rated current | Inrush current | Rated power | Rated current | Inrush current | Frame size | Order no. | Max. external moment of inertia | Weight for type of construction IM B5 | MN | PN | IN | I1 | PN | IN | I1 | | | Jext | | Nm | kW | A | A | kW | A | A | | | kgm2 | approx. kg | max. frequency 50 Hz at UN = 400 V/50 Hz, max. speed 1000 min-1 | 34 | 3.6 | 8.1 | 36 | - | - | - | 132 | 1FU8 134 - 6TD8� | 1.3 | 58 | 59.6 | 6.24 | 13.5 | 73 | - | - | - | 160 | 1FU8 167 - 6TD8� | 2 | 109 | max. frequency 100 Hz at UN = 200 V/50 Hz, max. speed 2000 min-1 | 34 | 3.6 | 16.2 | 70 | 7.2 | 17.1 | 93 | 132 | 1FU8 134 - 6TD6� | 1.3 | 58 | 59.6 | 6.24 | 26.8 | 146 | 12.48 | 28 | 188 | 160 | 1FU8 167 - 6TD6� | 2 | 109 | max. frequency 160 Hz at UN = 125 V/50 Hz, max. speed 3200 min-1 | 28.9 | 3 | 28 | 111 | 9.7 | 31.2 | 160 | 132 | 1FU8 134 - 6TD3� | 1.3 | 58 | 54.6 | 5.7 | 52 | 231 | 18.3 | 58 | 333 | 160 | 1FU8 167 - 6TD3� | 2 | 109 | max. frequency 200 Hz at UN = 100 V/50 Hz, max. speed 4000 min-1 | 28.9 | 3 | 35.1 | 140 | 12.1 | 42 | 203 | 132 | 1FU8 134 - 6TD2� | 1.3 | 58 | 54.6 | 5.7 | 65.5 | 290 | 22.9 | 78 | 437 | 160 | 1FU8 167 - 6TD2� | 1.5 | 109 |
When ordering options, an encrypted order code must additionally be specified for each design desired (plaintext where applicable). Order codes must not be repeated in plaintext. Order No.: 1FU8��� - �T��� - Z Order code(s) ��� +��� +��� Order no. supplement, 12th position of the order no., type of construction12th Order no. position, type of construction in accordance with DIN EN 60034-7 Size 71M to 160L
| | Code 12th position | Order code |
|---|
IM B3 |  | 0 | - | IM B6/IM 1051, IM B7/IM 1061, IM B8/IM 1071 |  |  | | 0 | - | IM V5/IM 1011 without protective cover | | 0 9 | - M1D | IM V6/IM 1031 |  | 0 9 | - M1E | IM V5/IM 1011 with protective cover |  | 9 1) | M1F | Flange | IM B5/IM 3001 |  | 1 | - | IM V5/IM 3011 without protective cover |  | 1 8 | - | IM V1/IM 3011 with protective cover |  | 4 1) | - | IM V3/IM 3031 | | 1 9 | - M1G | IM B35/IM 2001 | | 6 | - | Standard flange | IM B14/IM 3601, IM V19/IM 3631, IM V18/IM 3611 without protective cover | |  |  | 2 | - | IM V18/IM 3611 with protective cover |  | 9 1) | M2A | IM B34/IM 2101 |  | 7 | - | Special flange | IM B14/IM 3601, IM V19/IM 3631, IM V18/IM 3611 without protective cover | |  |  | 3 | - | IM V18/IM 3611 with protective cover |  | 9 1) | M2B | IM B34/IM 2101 |  | 9 | M2C |
The flanges are assigned to the frame sizes in DIN EN 50347 as FF with through-holes. A flanges in accordance with DIN 42948 continue to be valid. The standard flanges are assigned to the frame sizes in DIN EN 50347 as FT with threaded holes. C flanges in accordance with DIN 42948 continue to be valid. The special flange was assigned as a large flange in the previous DIN 42677. The dimensions of the following types of construction are identical: IM B3, IM B6, IM B7, IM B8, IM V5 and IM V6 IM B5, IM V1 and IM V3 IM B14, IM V18 and IM V19 The motors in the standard power range are available in the standard types of construction IM B3, IM B5 or IM B14, and can be operated in mounting positions IM B6, IM B7, IM B8, IM V5, IM V6, IM V1, IM V3 (up to frame size 160L) or IM V18 and IM V19. Eyebolts are available for transport and installation in a horizontal position. In conjunction with the eyebolts, for the purpose of stabilizing the position when the motor is arranged vertically, additional lifting straps (DIN EN 1492-1) and/or clamping bands (DIN EN 12195-2) must be used. If mounting position IM V1 is ordered, eyebolts are supplied for vertical mounting. For this reason, they are normally designated only with the basic type of construction on the rating plate. In the case of all types of construction with shaft end down, the version "with protective cover" is recommended. 1) Second shaft end K16 not possible.
|
|