Article number

6ES7321-7RD00-0AB0

SM321, 4DI, DC24V, HAZARDOUS AREAS

Supply voltage

 

Load voltage L+

 

  • â—� Rated value (DC)

24 V

  • â—� Reverse polarity protection

Yes

Input current

 

from load voltage L+ (without load), max.

50 mA

from backplane bus 5 V DC, max.

80 mA

Encoder supply

 

Type of output voltage

via the inputs

Power loss

 

Power loss, typ.

1.1 W

Digital inputs

 

Number of NAMUR inputs

4

Input voltage

 

  • â—� Rated value (DC)

8.2 V; from internal power circuit supply

Input current

 

  • â—� on wire-break, max.

0.1 mA

  • â—� on short-circuit, max.

8.5 mA

for NAMUR encoders

 

  • — for signal "0"

0.35 to 1.2 mA

  • — for signal "1"

2.1 to 7 mA

Input delay (for rated value of input voltage)

 

  • â—� Input frequency (with a time delay of 0.1 ms), max.

2 kHz

for NAMUR inputs

 

  • — Parameterizable

Yes; 0.1 / 0.5 / 3 / 15 / 20 ms (plus 0.25 ms preparation time)

Cable length

 

  • â—� unshielded, max.

200 m

Encoder

 

Connectable encoders

 

  • â—� NAMUR encoder

Yes; Two-wire connection

Interrupts/diagnostics/status information

 

Diagnostic functions

Yes

Diagnostic messages

 

  • â—� Diagnostic information readable

Yes

Diagnostics indication LED

 

  • â—� Group error SF (red)

Yes

  • â—� Status indicator digital input (green)

Yes

  • â—� Channel fault indicator F (red)

Yes

Ex(i) characteristics

 

Module for Ex(i) protection

Yes

Maximum values of input circuits (per channel)

 

  • â—� Co (permissible external capacity), max.

3 µF

  • â—� Io (short-circuit current), max.

14.1 mA

  • â—� Lo (permissible external inductivity), max.

100 mH

  • â—� Po (power of load), max.

33.7 mW

  • â—� Uo (output no-load voltage), max.

10 V

Potential separation

 

Potential separation digital inputs

 

  • â—� Potential separation digital inputs

Yes

  • â—� between the channels, in groups of

1

Standards, approvals, certificates

 

Use in hazardous areas

 

  • â—� Type of protection acc. to EN 50020 (CENELEC)

[EEx ib] IIC

  • â—� Type of protection acc. to FM

Class II, Division 2, Group A, B, C, D T4

  • â—� Test number PTB

Ex-96.D.2094X

Ambient conditions

 

Ambient temperature during operation

 

  • â—� max.

60 °C

Connection method

 

required front connector

20-pin

Weights

 

Weight, approx.

230 g


Article number

6ES7322-5SD00-0AB0

6ES7322-5RD00-0AB0

SM322, 4DO, 15V DC,10MA, HAZARDOUS AREAS

SM322, 4DO, 15V DC,20MA, HAZARDOUS AREAS

Supply voltage

 

 

Load voltage L+

 

 

  • â—� Rated value (DC)

24 V

24 V

  • â—� Reverse polarity protection

Yes

Yes

Input current

 

 

from load voltage L+ (without load), max.

160 mA

160 mA

from backplane bus 5 V DC, max.

85 mA

85 mA

Power loss

 

 

Power loss, typ.

3 W

3 W

Digital outputs

 

 

Number of digital outputs

4

4

Short-circuit protection

Yes; Electronic

Yes; Electronic

  • â—� Response threshold, typ.

Output current with short-circuit protection, min. 10 mA + 10 %

Output current with short-circuit protection, min. 20.5 mA + 10 %

Load resistance range

 

 

  • â—� upper limit

390 â„¦; Two-wire connection

200 â„¦; Two-wire connection

Output voltage

 

 

  • â—� Rated value (DC)

24 V

15 V

Output current

 

 

  • â—� for signal "1" permissible range for 0 to 60 °C, max.

10 mA; ±10 %

20 mA; ±10 %

Switching frequency

 

 

  • â—� with resistive load, max.

100 Hz

100 Hz

Cable length

 

 

  • â—� unshielded, max.

200 m

200 m

Interrupts/diagnostics/status information

 

 

Diagnostic functions

Yes

Yes

Diagnostic messages

 

 

  • â—� Diagnostic information readable

Yes

Yes

  • â—� Short-circuit

Yes

Yes

Diagnostics indication LED

 

 

  • â—� Group error SF (red)

Yes

Yes

  • â—� Status indicator digital output (green)

Yes

Yes

  • â—� Channel fault indicator F (red)

Yes

Yes

Ex(i) characteristics

 

 

Module for Ex(i) protection

Yes

Yes

Maximum values of output circuits (per channel)

 

 

  • â—� Co (permissible external capacity), max.

90 nF

500 nF

  • â—� Io (short-circuit current), max.

70 mA

85 mA

  • â—� Lo (permissible external inductivity), max.

6.7 mH

5 mH

  • â—� Po (power of load), max.

440 mW

335 mW

  • â—� Uo (output no-load voltage), max.

25.2 V

15.75 V

Potential separation

 

 

Potential separation digital outputs

 

 

  • â—� Potential separation digital outputs

Yes

Yes

  • â—� between the channels, in groups of

1

1

Standards, approvals, certificates

 

 

Use in hazardous areas

 

 

  • â—� Type of protection acc. to EN 50020 (CENELEC)

[EEx ib] IIC

[EEx ib] IIC

  • â—� Type of protection acc. to FM

Class I, Division 2, Group A, B, C, D T4

AIS CL.1, DIV 1, GP A, B, C, D; CL.I, DIV 2, GP A, B, C, D T4

  • â—� Test number PTB

Ex-96.D.2093X

Ex-96.D.2102X

Ambient conditions

 

 

Ambient temperature during operation

 

 

  • â—� max.

60 °C

60 °C

Connection method

 

 

required front connector

20-pin

20-pin

Weights

 

 

Weight, approx.

230 g

230 g


Article number

6ES7331-7RD00-0AB0

6ES7331-7SF00-0AB0

SIMATIC S7, SM 331 ANALOG INPUT

SIMATIC S7, SM 331 ANALOG INPUT

Supply voltage

 

 

Load voltage L+

 

 

  • â—� Rated value (DC)

24 V

24 V

  • â—� Reverse polarity protection

Yes

Input current

 

 

from load voltage L+ (without load), max.

250 mA

from backplane bus 5 V DC, max.

60 mA

120 mA

Output voltage

 

 

Power supply to the transmitters

 

 

  • â—� Rated value (DC)

13 V; at 22 mA

  • â—� No-load voltage (DC)

25.2 V

Power loss

 

 

Power loss, typ.

3 W

0.6 W

Analog inputs

 

 

Number of analog inputs

4

8; 8x thermocouples; 4x RTD thermoresistors

permissible input current for current input (destruction limit), max.

40 mA

Input ranges

 

 

  • â—� Voltage

No

Yes

  • â—� Current

Yes

No

  • â—� Thermocouple

No

Yes

  • â—� Resistance thermometer

No

Yes

  • â—� Resistance

No

Yes

Input ranges (rated values), currents

 

 

  • â—� 0 to 20 mA

Yes

  • â—� Input resistance (0 to 20 mA)

50 â„¦

  • â—� 4 mA to 20 mA

Yes

  • â—� Input resistance (4 mA to 20 mA)

50 â„¦

Input ranges (rated values), thermocouples

 

 

  • â—� Type B

Yes

  • â—� Input resistance (Type B)

10 MΩ

  • â—� Type E

Yes

  • â—� Input resistance (Type E)

10 MΩ

  • â—� Type J

Yes

  • â—� Input resistance (type J)

10 MΩ

  • â—� Type K

Yes

  • â—� Input resistance (Type K)

10 MΩ

  • â—� Type L

Yes

  • â—� Input resistance (Type L)

10 MΩ

  • â—� Type N

Yes

  • â—� Input resistance (Type N)

10 MΩ

  • â—� Type R

Yes

  • â—� Input resistance (Type R)

10 MΩ

  • â—� Type S

Yes

  • â—� Input resistance (Type S)

10 MΩ

  • â—� Type T

Yes

  • â—� Input resistance (Type T)

10 MΩ

  • â—� Type U

Yes

  • â—� Input resistance (Type U)

10 MΩ

Input ranges (rated values), resistance thermometer

 

 

  • â—� Ni 100

Yes

  • â—� Input resistance (Ni 100)

10 MΩ

  • â—� Pt 100

Yes

  • â—� Input resistance (Pt 100)

10 MΩ

  • â—� Pt 200

Yes

  • â—� Input resistance (Pt 200)

10 MΩ

Cable length

 

 

  • â—� shielded, max.

200 m

200 m; TC: 50 m

Analog value generation for the inputs

 

 

Measurement principle

Sigma Delta

Sigma Delta

Integration and conversion time/resolution per channel

 

 

  • â—� Resolution with overrange (bit including sign), max.

16 bit; 10 bit to 15 bit + sign

16 bit; 10 bit to 15 bit + sign

  • â—� Integration time, parameterizable

Yes; 2.5 to 100 ms

Yes; 2.5 to 100 ms

  • â—� Interference voltage suppression for interference frequency f1 in Hz

10 to 400 Hz

10 to 400 Hz

Encoder

 

 

Connection of signal encoders

 

 

  • â—� for current measurement as 2-wire transducer

Yes

Yes

  • â—� for current measurement as 4-wire transducer

Yes

Yes

Errors/accuracies

 

 

Temperature error (relative to input range), (+/-)

0.001 %/K; Temperature error: 0.001 to 0.002 %/K

Operational error limit in overall temperature range

 

 

  • â—� Current, relative to input range, (+/-)

0.45 %

  • â—� Resistance thermometer, relative to input range, (+/-)

0.04 %; 0.09 to 0.04%

Basic error limit (operational limit at 25 °C)

 

 

  • â—� Current, relative to input range, (+/-)

0.1 %

  • â—� Resistance thermometer, relative to input range, (+/-)

0.008 %; 0.018 ... 0.008%

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

 

 

  • â—� Series mode interference (peak value of interference < rated value of input range), min.

60 dB

60 dB

  • â—� Common mode interference, min.

130 dB

130 dB

Interrupts/diagnostics/status information

 

 

Diagnostic functions

Yes

Yes

Diagnostic messages

 

 

  • â—� Diagnostic information readable

Yes

Yes

  • â—� Overrange

Yes

Yes

  • â—� Wire-break in signal transmitter cable

Yes

Yes

  • â—� Short-circuit of the signal encoder cable

Yes

Yes

Diagnostics indication LED

 

 

  • â—� Group error SF (red)

Yes

Yes

  • â—� Channel fault indicator F (red)

Yes

Yes

Ex(i) characteristics

 

 

Module for Ex(i) protection

Yes

Yes

Maximum values of input circuits (per channel)

 

 

  • â—� Co (permissible external capacity), max.

90 nF

43 µF

  • â—� Io (short-circuit current), max.

68.5 mA

28.8 mA

  • â—� Lo (permissible external inductivity), max.

7.5 mH

40 mH

  • â—� Po (power of load), max.

431 mW

41.4 mW

  • â—� Ri, max.

50 â„¦

  • â—� Uo (output no-load voltage), max.

25.2 V

5.9 V

Potential separation

 

 

Potential separation analog inputs

 

 

  • â—� Potential separation analog inputs

Yes

Yes

Permissible potential difference

 

 

between the inputs (UCM)

60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area

60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area

Between the inputs and MANA (UCM)

60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area

60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area

Use in hazardous areas

 

 

  • â—� Type of protection acc. to EN 50020 (CENELEC)

[EEx ib] IIC

[EEx ib] IIC

  • â—� Type of protection acc. to FM

Class I, Division 2, Group A, B, C, D T4

Class I, Division 2, Group A, B, C, D T4

  • â—� Test number PTB

Ex-96.D.2092X

Ex-96.D.2108X

Ambient conditions

 

 

Ambient temperature during operation

 

 

  • â—� max.

60 °C

60 °C

Connection method

 

 

required front connector

20-pin

20-pin

Weights

 

 

Weight, approx.

290 g

210 g


Article number

6ES7332-5RD00-0AB0

SIMATIC S7,SM 332 ANALOG OUTPUT

Supply voltage

 

Load voltage L+

 

  • â—� Rated value (DC)

24 V

  • â—� Reverse polarity protection

Yes

Input current

 

from load voltage L+ (without load), max.

200 mA

from backplane bus 5 V DC, max.

80 mA

Power loss

 

Power loss, typ.

4 W

Analog outputs

 

Number of analog outputs

4

Voltage output, short-circuit protection

Yes

Voltage output, short-circuit current, max.

70 mA

Current output, no-load voltage, max.

14 V

Output ranges, current

 

  • â—� 0 to 20 mA

Yes

  • â—� 4 mA to 20 mA

Yes

Connection of actuators

 

  • â—� for current output two-wire connection

Yes

Load impedance (in rated range of output)

 

  • â—� with current outputs, max.

500 â„¦

Cable length

 

  • â—� shielded, max.

200 m

Analog value generation for the outputs

 

Integration and conversion time/resolution per channel

 

  • â—� Resolution with overrange (bit including sign), max.

15 bit

  • â—� Basic conversion time (ms)

2.5 ms

Errors/accuracies

 

Operational error limit in overall temperature range

 

  • â—� Current, relative to output range, (+/-)

0.55 %

Basic error limit (operational limit at 25 °C)

 

  • â—� Current, relative to output range, (+/-)

0.2 %

Interrupts/diagnostics/status information

 

Diagnostic functions

Yes

Diagnostic messages

 

  • â—� Diagnostic information readable

Yes

  • â—� Overrange

Yes

  • â—� Wire-break in actuator cable

Yes

Diagnostics indication LED

 

  • â—� Group error SF (red)

Yes

  • â—� Channel fault indicator F (red)

Yes

Ex(i) characteristics

 

Module for Ex(i) protection

Yes

Maximum values of output circuits (per channel)

 

  • â—� Co (permissible external capacity), max.

850 nF

  • â—� Io (short-circuit current), max.

70 mA

  • â—� Lo (permissible external inductivity), max.

6.6 mH

  • â—� Po (power of load), max.

440 mW

  • â—� Uo (output no-load voltage), max.

14 V

Potential separation

 

Potential separation analog outputs

 

  • â—� Potential separation analog outputs

Yes

Permissible potential difference

 

between the outputs (UCM)

60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area

Between the outputs and MANA (UCM)

60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area

Standards, approvals, certificates

 

Use in hazardous areas

 

  • â—� Type of protection acc. to EN 50020 (CENELEC)

[EEx ib] IIC

  • â—� Type of protection acc. to FM

Class I, Division 2, Group A, B, C, D T4

  • â—� Test number PTB

Ex-96.D.2026X

Ambient conditions

 

Ambient temperature during operation

 

  • â—� max.

60 °C

Connection method

 

required front connector

20-pin

Weights

 

Weight, approx.

280 g


















Êàòàëîã îáîðóäîâàíèÿ 2018
Siemens Industry Catalog Drive technology Automation technology Automation systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Industrial controls Industry software PC-based Automation Process control systems SIMATIC PCS 7 System components Software Media and Logistics System Administration Industrial Workstation/IPC Engineering System SIMATIC PCS 7 Plant Automation Accelerator Operator System Process Data Archiving and Reporting Plant Device Management Automation Systems Compact systems Industrial Communication Process I/O Central I/O for SIMATIC PCS 7 Power Supplies SIMATIC CFU SIMATIC ET 200SP HA SIMATIC ET 200iSP SIMATIC ET 200M for SIMATIC PCS 7 Power Supply Interface Modules Accessories Bundles Digital modules Analog Modules Analog modules with HART Ex Digital/Analog Modules F Digital/Analog Modules Control Modules Counter Modules MTA Terminal Modules SIMATIC ET 200SP for SIMATIC PCS 7 SIMATIC ET 200pro for SIMATIC PCS 7 Batch automation Route control Safety Integrated for Process Automation Industrial Security Technology components Simulation and Training Systems Update/Upgrade Packages Add-ons for SIMATIC PCS 7 PCS 7 Services Previous versions Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need