Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6ES7151-1CA00-1BL0

6ES7151-1CA00-3BL0

ET 200S COMPACT, 32DI STD,

ET 200S COMPACT, 16DI/16DO STD

General information

Vendor identification (VendorID)

8200H

Supply voltage

Load voltage 1L+

  • Rated value (DC)

24V

24V

  • Reverse polarity protection

Yes

Yes

Input current

from supply voltage 1L+, max.

100mA

100mA

Power loss

Power loss, typ.

3W

3W

Address area

Addressing volume

  • Inputs

100byte

100byte

  • Outputs

100byte

100byte

Digital inputs

Number of digital inputs

32

16

Input voltage

  • Type of input voltage

DC

DC

  • Rated value (DC)

24V

24V

  • for signal "0"

-30 to +5V

-30 to +5V

  • for signal "1"

13 to 30V

13 to 30V

Input current

  • for signal "1", typ.

4mA; At 24 V min. 2 mA

3mA

Input delay (for rated value of input voltage)

for standard inputs

  • at "0" to "1", min.

1.2ms; typically 3 ms

1.2ms; typically 3 ms

  • at "0" to "1", max.

4.8ms; typically 3 ms

4.8ms; typically 3 ms

  • at "1" to "0", min.

1.2ms; typically 3 ms

1.2ms; typically 3 ms

  • at "1" to "0", max.

4.8ms; typically 3 ms

4.8ms; typically 3 ms

Cable length

  • unshielded, max.

1000m

1000m

Digital outputs

Number of digital outputs

0

16

Short-circuit protection

Yes

Limitation of inductive shutdown voltage to

L+ (-55 to -60 V)

Controlling a digital input

Yes

Switching capacity of the outputs

  • on lamp load, max.

5W

Output voltage

  • for signal "1", min.

L+ (-0.8 V)

Output current

  • for signal "1" permissible range, min.

7mA

  • for signal "1" permissible range, max.

0.6A

  • for signal "0" residual current, max.

0.5mA

Output delay with resistive load

  • "0" to "1", max.

0.5ms

  • "1" to "0", max.

1.3ms

Switching frequency

  • with resistive load, max.

100Hz

  • with inductive load, max.

2Hz

  • on lamp load, max.

10Hz

Total current of the outputs (per group)

all mounting positions

  • up to 60 C, max.

2A

Cable length

  • unshielded, max.

1000m

Encoder

Connectable encoders

  • 2-wire sensor

Yes

  • permissible quiescent current (2-wire sensor), max.

1.5mA

Interfaces

Transmission procedure

RS 485

RS 485

Interface physics, RS 485

Yes

Yes

Interface physics, FOC

No

No

PROFIBUS DP

  • Output current, max.

80mA

  • Transmission rate, max.

12Mbit/s

  • Direct data exchange (slave-to-slave communication)

Yes

Yes

  • Cable length, max.

1200m

1200m

Protocols

Supports protocol for PROFINET IO

No

No

PROFIBUS DP

Yes

Yes

Protocols (Ethernet)

  • TCP/IP

No

No

Isochronous mode

Isochronous operation (application synchronized up to terminal)

No

No

Interrupts/diagnostics/status information

Alarms

No

No

Diagnostic functions

Yes

Yes

Diagnostics indication LED

  • Bus fault BF (red)

Yes

Yes

  • Group error SF (red)

Yes

Yes

  • Status indicator digital input (green)

Yes

  • Status indicator digital output (green)

Yes

  • Monitoring 24 V voltage supply ON (green)

Yes

Yes

Potential separation

between backplane bus and electronics

No

between supply voltage and electronics

No

Potential separation digital inputs

  • Potential separation digital inputs

No

Potential separation digital outputs

  • Potential separation digital outputs

Yes

Isolation

Isolation tested with

500 V DC

500 V DC

Degree and class of protection

IP degree of protection

IP20

IP20

Connection method

Design of electrical connection for the inputs and outputs

Screw-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection

Dimensions

Width

120mm

120mm

Height

81mm

81mm

Depth

58mm

58mm

Weights

Weight, approx.

230g; EB only


Article number

6ES7151-1AA06-0AB0

6ES7151-1AB05-0AB0

6ES7151-1BA02-0AB0

6ES7151-1CA00-0AB0

ET200S, IM151-1 STD, 12MBIT/S

ET200S, INTERFACE MODULE IM151-1 FO

ET200S, INTERF.MOD. IM151-1 HF, 12MBIT/S

ET200S, IM151-1 BASIC, 12MBIT/S

General information

Vendor identification (VendorID)

806Ah

806Bh

80F3h

Supply voltage

Mains buffering

  • Mains/voltage failure stored energy time

20ms

20ms

20ms

No

Input current

from supply voltage 1L+, max.

200mA

200mA

200mA

70mA

Output current

for backplane bus (5 V DC), max.

700mA

Power loss

Power loss, typ.

3.3W

3.3W

3.3W

1.5W

Address area

Addressing volume

  • Inputs

244byte

244byte

244byte

88byte

  • Outputs

244byte

244byte

244byte

88byte

Interfaces

Transmission procedure

RS 485

Interface physics, RS 485

Yes; 9-pin sub D socket

Yes

Yes; 9-pin sub D socket

Interface physics, FOC

Yes; 4 x Simplex socket

PROFIBUS DP

  • Output current, max.

80mA

80mA

  • Transmission rate, max.

12Mbit/s; 9,6 / 19,2 / 45,45 / 93,75 / 187,5 / 500 kbit/s; 1,5 / 3 / 6 / 12 Mbit/s

12Mbit/s; 9,6 / 19,2 / 45,45 / 93,75 / 187,5 / 500 kbit/s; 1,5 / 12 Mbit/s

12Mbit/s

12Mbit/s; 9,6 / 19,2 / 45,45 / 93,75 / 187,5 / 500 kbit/s; 1,5 / 3 / 6 / 12 Mbit/s

  • SYNC capability

Yes

Yes

Yes

Yes

  • FREEZE capability

Yes

Yes

Yes

Yes

  • Direct data exchange (slave-to-slave communication)

Yes

Yes

Yes

Yes

  • Cable length, max.

1200m

2m

Protocols

Supports protocol for PROFINET IO

No

No

No

No

PROFIBUS DP

Yes

Yes

Yes

Yes

Protocols (Ethernet)

  • TCP/IP

No

No

No

No

Isochronous mode

Isochronous operation (application synchronized up to terminal)

No

No

Yes

No

Interrupts/diagnostics/status information

Alarms

Yes

Yes

Yes

No

Diagnostic functions

Yes

Yes

Yes

Yes

Diagnostics indication LED

  • Bus fault BF (red)

Yes

Yes

Yes

Yes

  • Group error SF (red)

Yes

Yes

Yes

Yes

  • Monitoring 24 V voltage supply ON (green)

Yes

Yes

Yes

Yes

Potential separation

between backplane bus and electronics

No

No

No

No

between electronic block and PROFIBUS DP

Yes

Yes

Yes

between supply voltage and electronics

No

No

No

No

Permissible potential difference

between different circuits

75 V DC/60 V AC

500 V DC

75 V DC/60 V AC

75 V DC/60 V AC

Isolation

Isolation tested with

500 V DC

57 V DC/60 V AC

500 V DC

500 V DC

Standards, approvals, certificates

CE mark

Yes

Yes

UL approval

Yes

Yes

Ambient conditions

Ambient temperature during operation

  • min.

0C

0C

  • max.

60C

60C

Dimensions

Width

45mm

45mm

45mm

45mm

Height

119.5mm

119.5mm

119.5mm

119.5mm

Depth

75mm

75mm

75mm

75mm

Weights

Weight, approx.

150g

150g

150g

150g



















  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.