Article number

6ES7417-4XT07-0AB0

CPU 417-4, 32 MB, 4 INTERFACES

General information

 

Product type designation

CPU 417-4

HW functional status

01

Firmware version

V7.0

Engineering with

 

  • â—� Programming package

STEP 7 V5.4 or higher with HSP 261

CiR – Configuration in RUN

 

CiR synchronization time, basic load

60 ms

CiR synchronization time, time per I/O byte

7 µs

Supply voltage

 

Rated value (DC)

  • â—� 24 V DC

No; Power supply via system power supply

Input current

 

from backplane bus 5 V DC, typ.

1.3 A

from backplane bus 5 V DC, max.

1.6 A

from backplane bus 24 V DC, max.

600 mA; 150 mA per DP interface

from interface 5 V DC, max.

90 mA; At each DP interface

Power loss

 

Power loss, typ.

6.5 W

Power loss, max.

8 W

Memory

 

Type of memory

RAM

Work memory

 

  • â—� integrated

32 Mbyte

  • â—� integrated (for program)

16 Mbyte

  • â—� integrated (for data)

16 Mbyte

  • â—� expandable

No

Load memory

 

  • â—� expandable FEPROM

Yes; with Memory Card (FLASH)

  • â—� expandable FEPROM, max.

64 Mbyte

  • â—� integrated RAM, max.

1 Mbyte

  • â—� expandable RAM

Yes; with Memory Card (RAM)

  • â—� expandable RAM, max.

64 Mbyte

Backup

 

  • â—� present

Yes

  • â—� with battery

Yes; all data

  • â—� without battery

No

Battery

 

Backup battery

 

  • â—� Backup current, typ.

225 µA; up to 40 °C

  • â—� Backup current, max.

1 275 µA

  • â—� Backup time, max.

See reference manual, module data, Chapter 3.3

  • â—� Feeding of external backup voltage to CPU

5 V DC to 15 V DC

CPU processing times

 

for bit operations, typ.

7.5 ns

for word operations, typ.

7.5 ns

for fixed point arithmetic, typ.

7.5 ns

for floating point arithmetic, typ.

15 ns

CPU-blocks

 

DB

 

  • â—� Number, max.

16 000; Number range: 1 to 16000

  • â—� Size, max.

64 kbyte

FB

 

  • â—� Number, max.

8 000; Number range: 0 to 7999

  • â—� Size, max.

64 kbyte

FC

 

  • â—� Number, max.

8 000; Number range: 0 to 7999

  • â—� Size, max.

64 kbyte

OB

 

  • â—� Number, max.

see instruction list

  • â—� Size, max.

64 kbyte

  • â—� Number of free cycle OBs

1; OB 1

  • â—� Number of time alarm OBs

8; OB 10-17

  • â—� Number of delay alarm OBs

4; OB 20-23

  • â—� Number of cyclic interrupt OBs

9; OB 30-38 (shortest cycle that can be set = 500 µs)

  • â—� Number of process alarm OBs

8; OB 40-47

  • â—� Number of DPV1 alarm OBs

3; OB 55-57

  • â—� Number of isochronous mode OBs

4; OB 61-64

  • â—� Number of multicomputing OBs

1; OB 60

  • â—� Number of background OBs

1; OB 90

  • â—� Number of startup OBs

3; OB 100-102

  • â—� Number of asynchronous error OBs

9; OB 80-88

  • â—� Number of synchronous error OBs

2; OB 121, 122

Nesting depth

 

  • â—� per priority class

24

  • â—� additional within an error OB

2

Counters, timers and their retentivity

 

S7 counter

 

  • â—� Number

2 048

Retentivity

 

  • — adjustable

Yes

  • — lower limit

0

  • — upper limit

2 047

  • — preset

Z 0 to Z 7

Counting range

 

  • — lower limit

0

  • — upper limit

999

IEC counter

 

  • â—� Number

Unlimited (limited only by RAM capacity)

S7 times

 

  • â—� Number

2 048

Retentivity

 

  • — adjustable

Yes

  • — lower limit

0

  • — upper limit

2 047

  • — preset

No times retentive

Time range

 

  • — lower limit

10 ms

  • — upper limit

9 990 s

IEC timer

 

  • â—� present

Yes

  • â—� Type

SFB

  • â—� Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

 

retentive data area in total

Total working and load memory (with backup battery)

Flag

 

  • â—� Number, max.

16 kbyte; Size of bit memory address area

  • â—� Retentivity available

Yes

  • â—� Retentivity preset

MB 0 to MB 15

  • â—� Number of clock memories

8; in 1 memory byte

Data blocks

 

  • â—� Number, max.

16 000; Number range: 1 to 16000

  • â—� Size, max.

64 kbyte

Local data

 

  • â—� adjustable, max.

64 kbyte

  • â—� preset

32 kbyte

Address area

 

I/O address area

 

  • â—� Inputs

16 kbyte

  • â—� Outputs

16 kbyte

of which distributed

 

  • — MPI/DP interface, inputs

2 kbyte

  • — MPI/DP interface, outputs

2 kbyte

  • — DP interface, inputs

8 kbyte

  • — DP interface, outputs

8 kbyte

Process image

 

  • â—� Inputs, adjustable

16 kbyte

  • â—� Outputs, adjustable

16 kbyte

  • â—� Inputs, default

1 024 byte

  • â—� Outputs, default

1 024 byte

  • â—� consistent data, max.

244 byte

  • â—� Access to consistent data in process image

Yes

Subprocess images

 

  • â—� Number of subprocess images, max.

15

Digital channels

 

  • â—� Inputs

131 072

  • — of which central

131 072

  • â—� Outputs

131 072

  • — of which central

131 072

  • â—� Number of addressable digital I/Os, max.

131 072; Inputs and outputs in each case

Analog channels

 

  • â—� Inputs

8 192

  • — of which central

8 192

  • â—� Outputs

8 192

  • — of which central

8 192

  • â—� Number of addressable analog I/Os, max.

8 192; Inputs and outputs in each case

Hardware configuration

 

Number of expansion units, max.

21

connectable OPs

119

Multicomputing

Yes; 4 CPUs max. (with UR1 or UR2)

Interface modules

 

  • â—� Number of connectable IMs (total), max.

6

  • â—� Number of connectable IM 460s, max.

6

  • â—� Number of connectable IM 463s, max.

4; IM 463-2

Number of DP masters

 

  • â—� integrated

2

  • â—� via CP

10; CP 443-5 Extended

  • â—� via IM 467

4

  • â—� Mixed mode IM + CP permitted

No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode

  • â—� via interface module

2

  • â—� Number of pluggable S5 modules (via adapter capsule in central device), max.

6

Number of IO Controllers

 

  • â—� integrated

0

  • â—� via CP

4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode

Number of operable FMs and CPs (recommended)

 

  • â—� FM

Limited by number of slots and number of connections

  • â—� CP, PtP

CP 440: Limited by number of slots; CP 441: limited by number of connections

  • â—� PROFIBUS and Ethernet CPs

14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum

Slots

 

  • â—� required slots

2

Time of day

 

Clock

 

  • â—� Hardware clock (real-time)

Yes

  • â—� retentive and synchronizable

Yes

  • â—� Resolution

1 ms

  • â—� Deviation per day (buffered), max.

1.7 s; Power off

  • â—� Deviation per day (unbuffered), max.

8.6 s; For power On

Operating hours counter

 

  • â—� Number

16

  • â—� Number/Number range

0 to 15

  • â—� Range of values

SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours

  • â—� Granularity

1 hour

  • â—� retentive

Yes

Clock synchronization

 

  • â—� supported

Yes

  • â—� to MPI, master

Yes

  • â—� to MPI, slave

Yes

  • â—� to DP, master

Yes

  • â—� to DP, slave

Yes

  • â—� in AS, master

Yes

  • â—� in AS, slave

Yes

  • â—� on Ethernet via NTP

No; Via CP

  • â—� to IF 964 DP

Yes

Time difference in system when synchronizing via

 

  • â—� MPI, max.

200 ms

Interfaces

 

Interfaces/bus type

1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 2 x PROFIBUS DP (optionally pluggable)

Number of RS 485 interfaces

2; Combined MPI / PROFIBUS DP and PROFIBUS DP

Number of other interfaces

2; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)

1. Interface

 

Interface type

Integrated

Physics

RS 485 / PROFIBUS + MPI

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

150 mA

Number of connection resources

MPI: 44, DP: 32

Functionality

 

  • â—� MPI

Yes

  • â—� PROFIBUS DP master

Yes

  • â—� PROFIBUS DP slave

Yes

MPI

 

  • â—� Number of connections

44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

  • â—� Transmission rate, max.

12 Mbit/s

Services

 

  • — PG/OP communication

Yes

  • — Routing

Yes

  • — Global data communication

Yes

  • — S7 basic communication

Yes

  • — S7 communication

Yes

  • — S7 communication, as client

Yes

  • — S7 communication, as server

Yes

DP master

 

  • â—� Number of connections, max.

32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

  • â—� Transmission rate, max.

12 Mbit/s

  • â—� Number of DP slaves, max.

32

Services

 

  • — PG/OP communication

Yes

  • — Routing

Yes; S7 routing

  • — Global data communication

No

  • — S7 basic communication

Yes

  • — S7 communication

Yes

  • — S7 communication, as client

Yes

  • — S7 communication, as server

Yes

  • — Equidistance

Yes

  • — Isochronous mode

Yes

  • — SYNC/FREEZE

Yes

  • — Activation/deactivation of DP slaves

Yes

  • — Direct data exchange (slave-to-slave communication)

Yes

  • — DPV1

Yes

Address area

 

  • — Inputs, max.

2 kbyte

  • — Outputs, max.

2 kbyte

User data per DP slave

 

  • — User data per DP slave, max.

244 byte

  • — Inputs, max.

244 byte

  • — Outputs, max.

244 byte

  • — Slots, max.

244

  • — per slot, max.

128 byte

DP slave

 

  • â—� Number of connections

32

  • â—� GSD file

http://support.automation.siemens.com/WW/view/en/113652

  • â—� Transmission rate, max.

12 Mbit/s

  • â—� automatic baud rate search

No

  • â—� Address area, max.

32; Virtual slots

  • â—� User data per address area, max.

32 byte

  • — of which consistent, max.

32 byte

Services

 

  • — PG/OP communication

Yes; with interface active

  • — S7 routing

Yes; with interface active

  • — Global data communication

No

  • — S7 basic communication

No

  • — S7 communication

Yes

  • — S7 communication, as client

Yes

  • — S7 communication, as server

Yes

  • — Direct data exchange (slave-to-slave communication)

No

  • — DPV1

No

Transfer memory

 

  • — Inputs

244 byte

  • — Outputs

244 byte

2. Interface

 

Interface type

Integrated

Physics

RS 485 / PROFIBUS

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

150 mA

Number of connection resources

32

Functionality

 

  • â—� PROFIBUS DP master

Yes

  • â—� PROFIBUS DP slave

Yes

DP master

 

  • â—� Number of connections, max.

32

  • â—� Transmission rate, max.

12 Mbit/s

  • â—� Number of DP slaves, max.

125

Services

 

  • — PG/OP communication

Yes

  • — Routing

Yes; S7 routing

  • — Global data communication

No

  • — S7 basic communication

Yes

  • — S7 communication

Yes

  • — S7 communication, as client

Yes

  • — S7 communication, as server

Yes

  • — Equidistance

Yes

  • — Isochronous mode

Yes

  • — SYNC/FREEZE

Yes

  • — Activation/deactivation of DP slaves

Yes

  • — Direct data exchange (slave-to-slave communication)

Yes

  • — DPV1

Yes

Address area

 

  • — Inputs, max.

8 kbyte

  • — Outputs, max.

8 kbyte

User data per DP slave

 

  • — User data per DP slave, max.

244 byte

  • — Inputs, max.

244 byte

  • — Outputs, max.

244 byte

  • — Slots, max.

244

  • — per slot, max.

128 byte

DP slave

 

  • â—� Number of connections

32

  • â—� GSD file

http://support.automation.siemens.com/WW/view/en/113652

  • â—� Transmission rate, max.

12 Mbit/s

  • â—� Address area, max.

32

  • â—� User data per address area, max.

32 byte

  • — of which consistent, max.

32 byte

Services

 

  • — Routing

Yes; with interface active

Transfer memory

 

  • — Inputs

244 byte

  • — Outputs

244 byte

3. Interface

 

Interface type

Pluggable interface module (IF), technical data as for 2nd interface

Plug-in interface modules

IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

Physics

RS 485 / PROFIBUS

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

150 mA

automatic detection of transmission rate

No

Number of connection resources

32

Functionality

 

  • â—� MPI

No

  • â—� PROFIBUS DP master

Yes

  • â—� PROFIBUS DP slave

Yes

DP master

 

  • â—� Number of connections, max.

32

  • â—� Number of DP slaves, max.

125

Services

 

  • — PG/OP communication

Yes

  • — Routing

Yes; S7 routing

  • — Global data communication

No

  • — S7 basic communication

Yes

  • — S7 communication

Yes

  • — S7 communication, as client

Yes

  • — S7 communication, as server

Yes

  • — Equidistance

Yes

  • — Isochronous mode

Yes

  • — SYNC/FREEZE

Yes

  • — Activation/deactivation of DP slaves

Yes

  • — Direct data exchange (slave-to-slave communication)

Yes

  • — DPV0

Yes

  • — DPV1

Yes

Address area

 

  • — Inputs, max.

8 kbyte

  • — Outputs, max.

8 kbyte

User data per DP slave

 

  • — User data per DP slave, max.

244 byte

  • — Inputs, max.

244 byte

  • — Outputs, max.

244 byte

  • — Slots, max.

244

  • — per slot, max.

128 byte

DP slave

 

  • â—� Number of connections

32

  • â—� GSD file

http://support.automation.siemens.com/WW/view/en/113652

  • â—� Transmission rate, max.

12 Mbit/s

  • â—� automatic baud rate search

No

  • â—� Address area, max.

32

  • â—� User data per address area, max.

32 byte

  • — of which consistent, max.

32 byte

Services

 

  • — PG/OP communication

Yes

  • — S7 routing

Yes; with interface active

  • — Global data communication

No

  • — S7 basic communication

No

  • — S7 communication

Yes

  • — S7 communication, as client

Yes

  • — S7 communication, as server

Yes

  • — Direct data exchange (slave-to-slave communication)

No

  • — DPV1

No

Transfer memory

 

  • — Inputs

244 byte

  • — Outputs

244 byte

4. Interface

 

Interface type

Pluggable interface module (IF), technical data as for 2nd interface

Plug-in interface modules

IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

Open IE communication

 

  • â—� ISO-on-TCP (RFC1006)

Via CP 443-1 and loadable FB

  • — Data length, max.

1452 bytes via CP 443-1 Adv.

Isochronous mode

 

Isochronous operation (application synchronized up to terminal)

Yes; For PROFIBUS only

Equidistance

Yes

Number of DP masters with isochronous mode

4

User data per isochronous slave, max.

244 byte

shortest clock pulse

1 ms; 0.5 ms without use of SFC 126, 127

max. cycle

32 ms

Communication functions

 

PG/OP communication

Yes

  • â—� Number of connectable OPs without message processing

119

  • â—� Number of connectable OPs with message processing

119; When using Alarm_S/SQ and Alarm_D/DQ

Data record routing

Yes

Global data communication

 

  • â—� supported

Yes

  • â—� Number of GD loops, max.

16

  • â—� Number of GD packets, transmitter, max.

16

  • â—� Number of GD packets, receiver, max.

32

  • â—� Size of GD packets, max.

54 byte

  • â—� Size of GD packet (of which consistent), max.

1 variable

S7 basic communication

 

  • â—� supported

Yes

  • â—� User data per job, max.

76 byte

  • â—� User data per job (of which consistent), max.

1 variable

S7 communication

 

  • â—� supported

Yes

  • â—� as server

Yes

  • â—� as client

Yes

  • â—� User data per job, max.

64 kbyte

  • â—� User data per job (of which consistent), max.

462 byte; 1 variable

S5 compatible communication

 

  • â—� supported

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

  • â—� User data per job, max.

8 kbyte

  • â—� User data per job (of which consistent), max.

240 byte

  • â—� Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.

64/64

Standard communication (FMS)

 

  • â—� supported

Yes; Via CP and loadable FB

Web server

 

  • â—� supported

No

Number of connections

 

  • â—� overall

120

  • â—� usable for PG communication

119

  • — reserved for PG communication

1

  • — adjustable for PG communication, max.

0

  • â—� usable for OP communication

119

  • — reserved for OP communication

1

  • — adjustable for OP communication, max.

0

  • â—� usable for S7 basic communication

118

  • — reserved for S7 basic communication

0

  • — adjustable for S7 basic communication, max.

0

  • â—� usable for S7 communication

118

  • — reserved for S7 communication

0

  • — adjustable for S7 communication, max.

0

  • â—� usable for routing

59

  • — reserved for routing

0

  • — adjustable for routing, max.

0

S7 message functions

 

Number of login stations for message functions, max.

119; Max. 119 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)

Symbol-related messages

Yes

SCAN procedure

Yes

Program alarms

Yes

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks

Alarm 8-blocks

Yes

  • â—� Number of instances for alarm 8 and S7 communication blocks, max.

10 000

  • â—� preset, max.

1 200

Process control messages

Yes

Number of archives that can log on simultaneously (SFB 37 AR_SEND)

64

Number of messages

 

  • â—� overall, max.

1 024

  • â—� in 100 ms grid, max.

128

  • â—� in 500 ms grid, max.

512

  • â—� in 1000 ms grid, max.

1 024

Number of additional values

 

  • â—� with 100 ms grid, max.

1

  • â—� with 500, 1000 ms grid, max.

10

Test commissioning functions

 

Status block

Yes; Up to 16 simultaneously

Single step

Yes

Number of breakpoints

16

Status/control

 

  • â—� Status/control variable

Yes; Up to 16 variable tables

  • â—� Variables

Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

  • â—� Number of variables, max.

70; Status/control

Forcing

 

  • â—� Forcing

Yes

  • â—� Forcing, variables

Inputs, outputs, bit memories, peripheral inputs, peripheral outputs

  • â—� Number of variables, max.

512

Diagnostic buffer

 

  • â—� present

Yes

  • â—� Number of entries, max.

3 200

  • — adjustable

Yes

  • — preset

120

Service data

 

  • â—� can be read out

Yes

Standards, approvals, certificates

 

CE mark

Yes

CSA approval

Yes

UL approval

Yes

cULus

Yes

FM approval

Yes

RCM (formerly C-TICK)

Yes

KC approval

Yes

EAC (formerly Gost-R)

Yes

Use in hazardous areas

 

  • â—� ATEX

ATEX II 3G Ex nA IIC T4 Gc

Ambient conditions

 

Ambient temperature during operation

 

  • â—� min.

0 °C

  • â—� max.

60 °C

Configuration

 

Configuration software

 

  • â—� STEP 7

Yes

Programming

 

  • â—� Command set

see instruction list

  • â—� Nesting levels

7

  • â—� Access to consistent data in process image

Yes

  • â—� System functions (SFC)

see instruction list

  • â—� System function blocks (SFB)

see instruction list

Programming language

 

  • — LAD

Yes

  • — FBD

Yes

  • — STL

Yes

  • — SCL

Yes

  • — CFC

Yes

  • — GRAPH

Yes

  • — HiGraph®

Yes

Number of simultaneously active SFCs

 

  • — DPSYC_FR

2; SFC 11; per interface

  • — D_ACT_DP

8; SFC 12; per interface

  • — RD_REC

8; SFC 59; per interface

  • — WR_REC

8; SFC 58; per interface

  • — WR_PARM

8; SFC 55; per interface

  • — PARM_MOD

1; SFC 57; per interface

  • — WR_DPARM

2; SFC 56; per interface

  • — DPNRM_DG

8; SFC 13; per interface

  • — RDSYSST

8; SFC 51

  • — DP_TOPOL

1; SFC 103; per interface

Number of simultaneously active SFBs

 

  • — RDREC

8; SFB 52; per interface, but not more than 32 across all external interfaces

  • — WRREC

8; SFB 53; per interface, but not more than 32 across all external interfaces

Know-how protection

 

  • â—� User program protection/password protection

Yes

  • â—� Block encryption

Yes; With S7 block Privacy

Dimensions

 

Width

50 mm

Height

290 mm

Depth

219 mm

Weights

 

Weight, approx.

900 g