Article number | 6ES7405-0DA02-0AA0 | 6ES7405-0KA02-0AA0 | 6ES7405-0KR02-0AA0 | 6ES7405-0RA02-0AA0 |
|---|
| PS405 POWER SUPPLY, DC24/48/60V, DC5V/4A | SIMATIC S7-400, PS 405 POWER | POWERSUPP.PS405,DC24/48/60V,DC5V/10A,RED | PS405 POWER SUPPLY,DC24/48/60V,DC5V/20A |
|---|
General information | | | | | Product type designation | PS 405 | PS 405 | PS 405 | PS 405 | Supply voltage | | | | | Rated value (DC) | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | permissible range, lower limit (DC) | 19.2V; Dynamic 18.5 V | 19.2V; Dynamic 18.5 V | 19.2V; Dynamic 18.5 V | 19.2V; Dynamic 18.5 V | permissible range, upper limit (DC) | 72V; dynamic 75.5 V | 72V; dynamic 75.5 V | 72V; dynamic 75.5 V | 72V; dynamic 75.5 V | Mains buffering | | | | | | 20ms | 20ms | 20ms | 20ms | | Yes | Yes | Yes | Yes | Input current | | | | | Rated value at 24 V DC | 2A | 4A | 4A | 7A | Rated value at 48 V DC | 1000mA | 2A | 2A | 3.2A | Rated value at 60 V DC | 800mA | 1.6A | 1.6A | 2.5A | Inrush current, max. | 18A; Full width at half maximum 20 ms | 18A; Full width at half maximum 20 ms | 18A; Full width at half maximum 20 ms | 56A; Full width at half maximum 1.5 ms | Output voltage | | | | | Type of output voltage | DC | DC | DC | DC | Rated value (DC) | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Output current | | | | | for backplane bus (5 V DC), max. | 4A; no base load required | 10A; no base load required | 10A; no base load required | 20A; no base load required | for backplane bus (24 V DC), max. | 0.5A; idling-proof | 1A; idling-proof | 1A; idling-proof | 1A; idling-proof | Short-circuit protection | Yes | Yes | Yes | Yes | Power | | | | | Active power input, typ. | 48W | 95W | 95W | 168W | Power loss | | | | | Power loss, typ. | 16W | 20W | 20W | 44W | Battery | | | | | Backup battery | | | | | | Yes; 1x lithium AA; 3.6 V / 2.3 Ah | Yes; 2x lithium AA; 3.6 V / 2.3 Ah | Yes; 2x lithium AA; 3.6 V / 2.3 Ah | Yes; 2x lithium AA; 3.6 V / 2.3 Ah | Hardware configuration | | | | | Slots | | | | | | 1 | 2 | 2 | 2 | Potential separation | | | | | primary/secondary | Yes | Yes | Yes | Yes | Degree and class of protection | | | | | Equipment protection class | I, with protective conductor | I, with protective conductor | I, with protective conductor | I, with protective conductor | Standards, approvals, certificates | | | | | FM approval | Yes; Ta: 0 C to 60 C T4 | Yes; Ta: 0 C to 60 C T4 | Yes; Ta: 0 C to 60 C T4 | Yes; Ta: 0 C to 60 C T4 | Ambient conditions | | | | | Ambient temperature during operation | | | | | | 0C | 0C | 0C | 0C | | 60C | 60C | 60C | 60C | Connection method | | | | | Connecting cables/cross-sections | 3x 1.5 mm, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | Dimensions | | | | | Width | 25mm | 50mm | 50mm | 50mm | Height | 290mm | 290mm | 290mm | 290mm | Depth | 217mm | 217mm | 217mm | 217mm | Weights | | | | | Weight, approx. | 760g | 1200g | 1200g | 1300g |
Article number | 6ES7407-0DA02-0AA0 | 6ES7407-0KA02-0AA0 | 6ES7407-0KR02-0AA0 | 6ES7407-0RA02-0AA0 |
|---|
| POWER SUPPLY PS407, 120/230V UC,5V DC/4A | PS407 POWER SUPPLY,120/230V UC,5V DC/10A | POWERSUPP.PS407,UC120/230V,DC5V/10A,RED. | PS407 POWER SUPPLY,120/230V UC,5V DC/20A |
|---|
General information | | | | | Product type designation | PS 407 | PS 407 | PS 407 | PS 407 | Supply voltage | | | | | Rated value (DC) | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | permissible range, lower limit (DC) | 88V | 88V | 88V | 88V | permissible range, upper limit (DC) | 300V | 300V | 300V | 300V | Rated value (AC) | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | permissible range, lower limit (AC) | 85V | 85V | 85V | 85V | permissible range, upper limit (AC) | 264V | 264V | 264V | 264V | Line frequency | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | 47Hz | 47Hz | 47Hz | 47Hz | | 63Hz | 63Hz | 63Hz | 63Hz | Mains buffering | | | | | | 20ms | 20ms | 20ms | 20ms | | Yes | Yes | Yes | Yes | Input current | | | | | Rated value at 110 V DC | 350mA; at 120 V DC | 1A; at 120 V DC | 1A; at 120 V DC | 1.4A; at 120 V DC | Rated value at 230 V DC | 190mA | 0.5A | 0.5A | 0.7A | Rated value at 120 V AC | 0.42A | 0.9A | 0.9A | 1.4A | Rated value at 230 V AC | 0.22A | 0.5A | 0.5A | 0.7A | Inrush current, max. | 8.25A; Full width at half maximum 5 ms | 63A; Full width at half maximum 1 ms | 63A; Full width at half maximum 1 ms | 88A; Full width at half maximum 1.1 ms | Output voltage | | | | | Type of output voltage | DC | DC | DC | DC | Rated value (DC) | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Output current | | | | | for backplane bus (5 V DC), max. | 4A; no base load required | 10A; no base load required | 10A; no base load required | 20A; no base load required | for backplane bus (24 V DC), max. | 0.5A; idling-proof | 1A; idling-proof | 1A; idling-proof | 1A; idling-proof | Short-circuit protection | Yes | Yes | Yes | Yes | Power | | | | | Active power input, typ. | 52W | 95W | 95W | 158W | Power loss | | | | | Power loss, typ. | 20W | 20W | 20W | 35W | Battery | | | | | Backup battery | | | | | | Yes; 1x lithium AA; 3.6 V / 2.2 Ah | Yes; 1x lithium AA; 3.6 V / 2.2 Ah | Yes; 1x lithium AA; 3.6 V / 2.2 Ah | Yes; 1x lithium AA; 3.6 V / 2.2 Ah | Hardware configuration | | | | | Slots | | | | | | 1 | 2 | 2 | 2 | Potential separation | | | | | primary/secondary | Yes | Yes | Yes | Yes | EMC | | | | | Compliance with line harmonic distortion limits | | | | | | Yes | Yes | Yes | Yes | Degree and class of protection | | | | | Equipment protection class | I, with protective conductor | I, with protective conductor | I, with protective conductor | I, with protective conductor | Standards, approvals, certificates | | | | | FM approval | Yes; Ta: 0 C to 70 C T4 | Yes; Ta: 0 C to 70 C T4 | Yes; Ta: 0 C to 70 C T4 | Yes; Ta: 0 C to 70 C T4 | Ambient conditions | | | | | Ambient temperature during operation | | | | | | 0C | 0C | 0C | 0C | | 60C | 60C | 60C | 60C | Connection method | | | | | Connecting cables/cross-sections | 3x 1.5 mm, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | Dimensions | | | | | Width | 25mm | 50mm | 50mm | 50mm | Height | 290mm | 290mm | 290mm | 290mm | Depth | 217mm | 217mm | 217mm | 217mm | Weights | | | | | Weight, approx. | 760g | 1200g | 1200g | 1300g |
|
|