Suitable for PM240?2 Power Module push-through variant 380 ... 480 V 3 AC
Type
–
6SL3211-1PE18-0 . L1
6SL3211-1PE21-8 . L0
6SL3211-1PE23-3 . L0
Frame size
FSA
FSA
FSB
FSC
Line voltage 380 ... 480 V 3 AC
Braking resistor
JJY:023422620001
JJY:023424020001
JJY:023434020001
JJY:023454020001 1)
JJY:023464020001 2)
Resistance
?
25
15
10
7.1
5
Rated power PDB
(continuous braking power)
kW
1.1
1.85
2.75
3.85
5.5
Peak power Pmax
(load duration ta = 12 s with period t = 240 s)
kW
22
37
55
77
110
Power connection
Cable
Cable
Cable
Cable
Cable
Thermostatic switch
Integrated
Integrated
Integrated
Integrated
Integrated
Degree of protection
IP21
IP21
IP21
IP21
IP21
Dimensions
Width
mm (in)
470 (18.5)
610 (24.0)
630 (24.8)
1)
2)
Height
mm (in)
220 (8.66)
220 (8.66)
350 (13.78)
1)
2)
Depth
mm (in)
180 (7.09)
180 (7.09)
180 (7.09)
1)
2)
Weight, approx.
kg (lb)
7 (15.4)
9.5 (20.9)
13.5 (29.8)
20.5 (45.2)
27 (59.5)
Suitable for PM240?2 Power Module
Type
6SL3210-1PE23-8 . L0 6SL3210-1PE24-5 . L0
6SL3210-1PE26-0 . L0 6SL3210-1PE27-5 . L0
6SL3210-1PE28-8 . L0 6SL3210-1PE31-1 . L0
6SL3210-1PE31-5 . L0 6SL3210-1PE31-8 . L0
6SL3210-1PE32-1 . L0 6SL3210-1PE32-5 . L0
Frame size
FSD
FSD
FSE
FSF
FSF
1) This braking resistor consists of the two braking resistors, JJY:023422620001 and JJY:023434020001, which must be connected in parallel on the plant/system side.
2) This braking resistor consists of two JJY:023434020001 braking resistors, which must be connected in parallel on the plant/system side.