Low level (an open digital input is interpreted as "low")
-3 V ... +5 V
High level
15 ... 30 V
Current consumption at 24 V DC, typ.
10 mA
Conductor cross-section, max.
1.5 mm2
Digital outputs
(sustained-short-circuit-proof)
Voltage
24 V DC
Load current per digital output, max.
100 mA
Conductor cross-section, max.
1.5 mm2
Current carrying capacity
24 V DC busbars
20 A
DC link busbars
100 A
PE connection
M5 screw
Dimensions
Width
50 mm (1.97 in)
Height
270 mm (10.63 in)
Depth
226 mm (8.90 in)
Weight, approx.
2.7 kg (5.95 lb)
Certificate of suitability
cURus
1) The activation threshold of the Braking Module in booksize compact format can be set on a DIP switch. The higher values for peak or rated braking power apply in operation at the upper activation threshold 775 V DC (factory setting). The outputs specified in parentheses are possible at the lower activation threshold 410 V DC.
2) Several Braking Modules in the booksize format can be operated in parallel, typically up to 4 modules.