510 ... 720 V DC (line voltage 380 ... 480 V 3 AC)
Output frequency
Control mode Servo
0 ... 650 Hz 1) 2) 3)
Control mode Vector
0 ... 300 Hz 2)
Control mode V/f
0 ... 600 Hz 2) 3)
Electronics power supply
24 V DC -15 %/+20 %
Type of cooling
Internal air cooling (power units with increased air cooling by built-in fan)
Permissible ambient and coolant temperature (air)
during operation for line-side components, Line Modules and Motor Modules
0 ... 40 °C (32 ... 104 °F) without derating, > 40 ... 55 °C (104 ... 131 °F), see derating characteristics
Installation altitude
Up to 1000 m (3281 ft) above sea level without derating, > 1000 ... 4000 m (3281 ... 13124 ft) above sea level, see derating characteristics
Declarations of conformity
CE (Low Voltage and EMC Directives)
Certificate of suitability
cULus
Safety Integrated
Safety Integrity Level 2 (SIL 2) according to IEC 61508, Performance Level d (PL d) and Category 3 according to EN ISO 13849?1
For further information, see section Safety Integrated.
1) At rated output current (max. output frequency 1300 Hz for 62.5 µs current control cycle, 8 kHz pulse frequency, 60 % permissible output current).
2) Note the correlation between max. output frequency, pulse frequency and current derating. For further information, see section Tools and configuring.
3) The output frequency is currently limited to 550 Hz. The specified values apply to systems with license for high output frequency. For further information, see section Control Units and https://support.industry.siemens.com/cs/document/104020669
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A
Motor cable length, max.
Shielded
m (ft)
50 (164)
50 (164)
50 (164)
70 (230)
Unshielded
m (ft)
75 (246)
75 (246)
75 (246)
100 (328)
Degree of protection
IP20
IP20
IP20
IP20
Dimensions
Width
mm (in)
50 (1.97)
50 (1.97)
50 (1.97)
100 (3.94)
Height
mm (in)
380 (14.96)
380 (14.96)
380 (14.96)
380 (14.96)
Depth
mm (in)
270 (10.63)
270 (10.63)
270 (10.63)
270 (10.63)
Weight, approx.
kg (lb)
4.7 (10.4)
4.7 (10.4)
4.7 (10.4)
7.7 (17.0)
1) Rated power of a typical standard asynchronous (induction) motor at 600 V DC link voltage.
2) Rated DC link current for dimensioning an external DC connection. For DC link current calculation for dimensioning the Line Module, see section Tools and configuring.
3) If, due to a number of Line Modules and Motor Modules being mounted side-by-side, the current carrying capacity exceeds 20 A, an additional 24 V DC connection using a 24 V terminal adapter is required (max. cross-section 6 mm2, max. fuse protection 20 A).
4) Power loss of Motor Module at rated power including losses of 24 V DC electronics power supply.
5) Connector not included in scope of supply, see Accessories.
6) At max. motor cable length 30 m (98.43 ft), pulse frequency 4 kHz and DC link voltage 540 ... 600 V.