|
| | | | | |
Plug-in transceivers for SCALANCE XM-400 managedOrder number | 6GK5991-1AD00-8AA0 | 6GK5991-1AF00-8AA0 | 6GK5991-1AE00-8AA0 | 6GK5991-1AE30-8AA0 |
|---|
Product type designation | SFP991-1 | SFP991-1LD | SFP991-1LH+ | SFP991-1ELH200 |
|---|
Interfaces | | | | | Number of electrical/optical connections for network components or terminal equipment maximum | 1 | 1 | 1 | 1 | Number of optical interfaces for network components or terminal equipment maximum | 1 | 1 | 1 | 1 | Number of 100 Mbit/s LC ports | 1 | 1 | 1 | 1 | Design of the optical interface for network components or terminal equipment | LC | LC | LC | LC | Wavelength of the optical interface | 1 310 nm; Multi-mode | 1 310 nm; Single-mode | 1 550 nm; Single-mode | 1 550 nm; Single-mode | Connectable optical power relative to 1 mW | | | | | | -19 dB | -15 dB | -5 dB | 1 dB | | -14 dB | -8 dB | 0 dB | 5 dB | | -3 dB | -3 dB | -3 dB | -9 dB | Optical sensitivity relating to 1 mW of the receiver input minimum | -32 dB | -34 dB | -34 dB | -42 dB | Damping ratio of the FOC transmission link minimum necessary | 0 dB | 0 dB | 3 dB | 14 dB | Range at the optical interface depending on the optical fiber used | 0 ... 5 km | 0 ... 26 km | 12 ... 70 km | 61 ... 200 km | Permitted ambient conditions | | | | | Ambient temperature | | | | | | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | Relative humidity at 25 °C without condensation during operation maximum | 95 % | 95 % | 95 % | 95 % | Protection class IP | IP20 | IP20 | IP20 | IP20 | Design, dimensions and weight | | | | | Design | SFP Module | SFP Module | SFP Module | SFP Module | Width | 13.7 mm | 13.7 mm | 13.7 mm | 13.7 mm | Height | 11.9 mm | 11.9 mm | 11.9 mm | 11.9 mm | Depth | 56.5 mm | 56.5 mm | 56.5 mm | 56.5 mm | Net weight | 0.01 kg | 0.01 kg | 0.01 kg | 0.01 kg | Mounting type | latched | latched | latched | latched | Standards, specifications, approvals | | | | | Standard | | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X | | UL 60950-1, CSA C22.2 No. 60950-1-03 | UL 60950-1, CSA C22.2 No. 60950-1-03 | UL 60950-1, CSA C22.2 No. 60950-1-03 | UL 60950-1, CSA C22.2 No. 60950-1-03 | | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | Certificate of suitability | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | MTBF at 40 °C | 120 y | 120 y | 120 y | 120 y |
Order number | 6GK5992-1AL00-8AA0 | 6GK5992-1AM00-8AA0 | 6GK5992-1AN00-8AA0 |
|---|
Product type designation | SFP992-1 | SFP992-1LD | SFP992-1LH |
|---|
Interfaces | | | | Number of electrical/optical connections for network components or terminal equipment maximum | 1 | 1 | 1 | Number of optical interfaces for network components or terminal equipment maximum | 1 | 1 | 1 | Number of 1000 Mbit/s LC ports for single mode (LD) Integrated | | 1 | 1 | Number of 1000 Mbit/s LC ports for multimode Integrated | 1 | | | Design of the optical interface for network components or terminal equipment | LC | LC | LC | Wavelength of the optical interface | 850 nm; Multi-mode | 1 310 nm; Single-mode | 1 550 nm; Single-mode | Connectable optical power relative to 1 mW | | | | | -9.5 dB | -9.5 dB | -6 dB | | -4 dB | -3 dB | 0 dB | | -3 dB | -3 dB | -3 dB | Optical sensitivity relating to 1 mW of the receiver input minimum | -17 dB | -21 dB | -23 dB | Damping ratio of the FOC transmission link minimum necessary | 0 dB | 0 dB | 3 dB | Range at the optical interface depending on the optical fiber used | 0 ... 0.75 km | 0 ... 10 km | 8 ... 40 km | Permitted ambient conditions | | | | Ambient temperature | | | | | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | Relative humidity at 25 °C without condensation during operation maximum | 95 % | 95 % | 95 % | Protection class IP | IP20 | IP20 | IP20 | Design, dimensions and weight | | | | Design | SFP Module | SFP Module | SFP Module | Width | 13.7 mm | 13.7 mm | 13.7 mm | Height | 11.9 mm | 11.9 mm | 11.9 mm | Depth | 56.5 mm | 56.5 mm | 56.5 mm | Net weight | 0.01 kg | 0.01 kg | 0.01 kg | Mounting type | latched | latched | latched | Standards, specifications, approvals | | | | Standard | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X | | UL 60950-1, CSA C22.2 No. 60950-1-03 | UL 60950-1, CSA C22.2 No. 60950-1-03 | UL 60950-1, CSA C22.2 No. 60950-1-03 | | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | Certificate of suitability | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | | Yes | Yes | Yes | | Yes | Yes | Yes | | No | No | No | MTBF at 40 °C | 120 y | 120 y | 120 y |
Order number | 6GK5992-1AP00-8AA0 | 6GK5992-1AQ00-8AA0 |
|---|
Product type designation | SFP992-1LH+ | SFP992-1ELH |
|---|
Interfaces | | | Number of electrical/optical connections for network components or terminal equipment maximum | 1 | 1 | Number of optical interfaces for network components or terminal equipment maximum | 1 | 1 | Number of 1000 Mbit/s LC ports for single mode (LD) Integrated | 1 | 1 | Design of the optical interface for network components or terminal equipment | LC | LC | Wavelength of the optical interface | 1 550 nm; Single-mode | 1 550 nm; Single-mode | Connectable optical power relative to 1 mW | | | | 0 dB | 0 dB | | 5 dB | 5 dB | | -3 dB | -8 dB | Optical sensitivity relating to 1 mW of the receiver input minimum | -23 dB | -32 dB | Damping ratio of the FOC transmission link minimum necessary | 8 dB | 8 dB | Range at the optical interface depending on the optical fiber used | 30 ... 70 km | 37 ... 120 km | Permitted ambient conditions | | | Ambient temperature | | | | -40 ... +85 °C | -40 ... +85 °C | | -40 ... +85 °C | -40 ... +85 °C | | -40 ... +85 °C | -40 ... +85 °C | | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | Relative humidity at 25 °C without condensation during operation maximum | 95 % | 95 % | Protection class IP | IP20 | IP20 | Design, dimensions and weight | | | Design | SFP Module | SFP Module | Width | 13.7 mm | 13.7 mm | Height | 11.9 mm | 11.9 mm | Depth | 56.5 mm | 56.5 mm | Net weight | 0.01 kg | 0.01 kg | Mounting type | latched | latched | Standards, specifications, approvals | | | Standard | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X | | UL 60950-1, CSA C22.2 No. 60950-1-03 | UL 60950-1, CSA C22.2 No. 60950-1-03 | | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | | EN 61000-6-2:2005 | EN 61000-6-2:2005 | Certificate of suitability | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | | Yes | Yes | | Yes | Yes | | No | No | MTBF at 40 °C | 120 y | 120 y |
Order number | 6GK5991-1AB00-8AA0 | 6GK5991-1AC00-8AA0 | 6GK5992-1AJ00-8AA0 | 6GK5992-1AK00-8AA0 |
|---|
Product type designation | STP991-1 | STP991-1LD | SCP992-1 | SCP992-1LD |
|---|
Suitability for operation | SCALANCE XM408-4C | SCALANCE XM-408-4C | SCALANCE XM-408-4C | SCALANCE XM-408-4C | Interfaces | | | | | Number of electrical/optical connections for network components or terminal equipment maximum | 1 | 1 | 1 | 1 | Number of optical interfaces for network components or terminal equipment maximum | 1 | 1 | 1 | 1 | Number of 100 Mbit/s ST(BFOC) ports for multimode Integrated | 1 | 1 | | | Number of 1000 Mbit/s SC ports (LX) | | | | 1 | Number of 1000 Mbit/s SC ports (SX) | | | 1 | | Design of the optical interface for network components or terminal equipment | ST/BFOC | ST/BFOC | SC | SC | Wavelength of the optical interface | 1 310 nm; Multi-mode | 1 310 nm; Single-mode | 850 nm; Multi-mode | 1 310 nm; Single-mode | Connectable optical power relative to 1 mW | | | | | | -19 dB | -15 dB | -9.5 dB | -9.5 dB | | -14 dB | -8 dB | -4 dB | -3 dB | | -3 dB | -3 dB | -3 dB | -3 dB | Optical sensitivity relating to 1 mW of the receiver input minimum | -32 dB | -34 dB | -17 dB | -21 dB | Damping ratio of the FOC transmission link minimum necessary | 0 dB | 0 dB | 0 dB | 0 dB | Range at the optical interface depending on the optical fiber used | 0 ... 5 km | 0 ... 26 km | 0 ... 0.75 km | 0 ... 10 km | Permitted ambient conditions | | | | | Ambient temperature | | | | | | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | -40 ... +85 °C | | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours | Relative humidity at 25 °C without condensation during operation maximum | 95 % | 95 % | 95 % | 95 % | Protection class IP | IP20 | IP20 | IP20 | IP20 | Design, dimensions and weight | | | | | Design | Plug-in transceiver | Plug-in transceiver | Plug-in transceiver | Plug-in transceiver | Width | 25.4 mm | 25.4 mm | 25.4 mm | 25.4 mm | Height | 10.2 mm | 10.2 mm | 10.2 mm | 10.2 mm | Depth | 56.5 mm | 56.5 mm | 56.5 mm | 56.5 mm | Net weight | 0.06 kg | 0.06 kg | 0.06 kg | 0.06 kg | Mounting type | latched, only with SCALANCE XM408-4C | latched, only with SCALANCE XM408-4C | latched, only with SCALANCE XM408-4C | latched, only with SCALANCE XM408-4C | Standards, specifications, approvals | | | | | Standard | | | | | | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class A) | | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2 | Certificate of suitability | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No |
|
|