SIDOOR ATE500E elevator door driveDuring initial commissioning, please note the following: - Mechanical mounting and setting, see the SIDOOR EC System Manual, and the ATE500E and MED280 Operating Instructions
- Electrical configuration and commissioning:
- Push the door into the "CLOSED" position.
- Open the device cover
- Plug in the motor connector
- Connect NT40 switch mode power or SIDOOR Transformer to 230 V AC mains supply
- Press and hold the learn run button
- Connect NT40 switch-mode power supply or SIDOOR Transformer to the input of the SIDOOR ATE500E elevator door drive
- The learn run starts automatically and the learn run button can be released as soon as the door starts to move
- On completion of the learn run, the door is in the "CLOSED" position and the 7-segment display indicates "u".
- The door can now be moved using the "OPEN" and "CLOSE" buttons with the default profile.
|
|