General data | |
Connection of field devices | - Standard-compliant field devices for PROFIBUS PA or FOUNDATION Fieldbus H1
- Max. 4 per AFD4/AFD4 RAILMOUNT/AFD4 FM
- Max. 8 per AFD8
- Max. 31 per fieldbus segment
- Operating environment up to Zone 2 or 22; Class I Zone 2/ Division 2
(with AFD4 RAILMOUNT depending on enclosure used) - The max. current consumption of all fieldbus components of the FF fieldbus segment is 0.5 A
|
Degree of protection | |
| IP66 |
| Depending on enclosure used |
Voltages, currents, potentials | |
Power supply | Via bus, no auxiliary power necessary |
Rated supply voltage, permissible range | 16 to 32 V DC |
Reverse polarity protection (together with FDC 157) | Yes |
Overvoltage protection | No |
Current consumption | |
- Current consumption at idle
| |
- AFD4, AFD4 RAILMOUNT, AFD4 FM
| 24 mA |
| 34 mA |
- Current consumption with connected field devices
| |
- AFD4, AFD4 RAILMOUNT, AFD4 FM
| 24 mA + total current of all field devices |
| 34 mA + total current of all field devices |
- Additional current consumption of the AFD at end of line (an open main line connection)
| 30 mA |
- Current consumption at max. power output per spur line
| |
- AFD4, AFD4 RAILMOUNT, AFD4 FM
| 264 mA |
| 514 mA |
Power loss | |
- AFD4, AFD4 RAILMOUNT, AFD4 FM
| Min. 384 mW; max. 3.2 W |
| min. 544 mW; max. 4.1 W |
Grounding | Direct, via grounding rail |
Electrical isolation between main line and spur lines | No |
Connections, interfaces | |
Main line | |
Number of connections | 2 |
Cable bushings | |
| Cable glands M16 |
| No cable glands/threaded plugs |
| Terminal screws M20 |
| Cable glands M16 |
Interfaces | PROFIBUS PA and FOUNDATION Fieldbus H1 |
Automatic bus terminator | Yes |
Spur lines | |
Number of connections | |
- AFD4, AFD4 RAILMOUNT, AFD4 FM
| 4 |
| 8 |
Cable bushings | |
| Cable glands M16 |
| No cable glands/threaded plugs |
| Terminal screws M16 |
| Cable glands M16 |
Short-circuit proof | Yes |
Intrinsically-safe acc. to FISCO | No |
Current Imax (DC) on spur lines 1 to 4 (AFD4) or 1 to 8 (AFD8) | 60 mA |
Short-circuit current (test current) | 6 mA |
Debounce logic | Yes |
No-load voltage | < 30 V |
Current output to field devices | |
- AFD4, AFD4 RAILMOUNT, AFD4 FM
| Max. 240 mA |
| Max. 480 mA |
Status, interrupts, diagnostics | |
Status indicator | Yes |
Diagnostics function | Yes |
Diagnostics LED | Yes |
Interrupts | No |
Climatic conditions | |
Permissible operating temperature | -40 to +70 °C |
Permissible storage/transport temperature | -40 to +85 °C |
Relative humidity during operation | Max. 95 % |
Approvals for potentially explosive atmospheres | |
| Zone 2 (AFD4 RAILMOUNT depending on enclosure used) |
| Zone 22 (AFD4 RAILMOUNT depending on enclosure used) |
Dimensions and weight | |
Dimensions (W ? H ? D) in mm (without screwed glands) | |
- AFD4, AFD4 RAILMOUNT, AFD4 FM
| 220 ? 120 ? 83 |
| 360 ? 120 ? 83 |
Weight | |
| 2 000 g |
| 1 000 g |
| 3 000 g |
Approvals, standards | |
AFD4, AFD4 RAILMOUNT and AFD8 | |
| According to 94/9/EG (formerly ATEX 100a), 2004/108/EG and 2006/95/EG |
| II 3G Ex nA ic [ic] IIC T4 Gc II 3D Ex tc [ic] IIIC T80°C Dc IP66 |
| IECEx DEK 12.0069X |
| Korea Certification |
| Ex nA [ic] IIC T4 Gc Ex tc [ic] IIIC T80 °C |
AFD4 FM | |
| FM Class 3600, 3611, 3810, ANSI/ISA 60079-0/-31, ANSI/ISA 60529, ANSI/NEMA250 |