General information | |
Product brand name | SIDOOR |
Product designation | Door controller |
Product version | ATD400V relay |
Optional product expansion | Mains transformer (6FB1112-0AT20-2TR0) |
Manufacturer's article no. of the usable motor | 6FB1103-0AT10-3MC0, 6FB1103-0AT11-3MC0 |
Manufacturer's article no. of the usable power supply unit | 6FB1112-0AT20-2TR0, 6FB1112-0AT20-3PS0 |
Supply voltage | |
Type of power supply | via SIDOOR mains transformer / NT40 |
Input current | |
Current consumption, max. | 10 A |
I?t, min. | 30 A?·s |
Power | |
Active power input | 80 W |
Active power input, max. | 540 W |
Active power input (standby mode) | 5 W |
Digital inputs | |
Control inputs isolated | Yes |
Control inputs p-switching | Yes |
Input voltage | |
| 10 V; Observe polarity ! |
| 28 V; Observe polarity ! |
Input current | |
| 9 mA |
| 27 mA |
Digital outputs | |
short-circuit proof | Yes |
Remark | Ensure correct polarity! CAUTION: Do not supply with external voltage! |
Output voltage | |
| 24 V |
Output current | |
| 400 mA |
Relay outputs | |
Switching capacity of contacts | |
| 0.01 A; 50 V DC switching voltage not released for NFPA-relevant countries |
| 1 A; 50 V DC switching voltage not released for NFPA-relevant countries |
| 0.01 A |
| 1 A |
Mechanical data | |
Opening width of door, min. | 0.3 m |
Opening width of door, max. | 4 m |
Weight of door, max. | 400 kg |
Operating cycle frequency of door, max. | 180 1/h |
Counterforce, max. | 80 N |
Kinetic energy, max. | 100 J |
Counterweight | |
| 8 kg |
Interfaces | |
Interfaces/bus type | without |
Degree and class of protection | |
IP degree of protection | IP20 |
Standards, approvals, certificates | |
Certificate of suitability according to EN 81 | Yes |
CE mark | Yes |
UL approval | No |
EAC (formerly Gost-R) | Yes |
TUV Inspectorate approval | Yes |
TUV prototype tested | Yes |
Standard for EMC | EN 12015 / EN 12016 |
Standard for safety | EN 60950-1 / EN 81-20 |
Ambient conditions | |
Ambient temperature during operation | |
| -20 °C |
| 50 °C |
Ambient temperature during storage/transportation | |
| -40 °C |
| 50 °C |
Air pressure acc. to IEC 60068-2-13 | |
| 2 000 m |
Relative humidity | |
| 10 % |
| 93 % |
Dimensions | |
Width | 320 mm |
Height | 60 mm |
Depth | 80 mm |