Possible applications | - Platform scales
- Small conveyor scales
|
Model | Platform load cell |
Loads | |
Rated load Emax | - 5 kg (11.02 lb)
- 10 kg (22.05 lb)
- 20 kg (44.09 lb)
- 50 kg (110.23 lb)
- 100 kg (220.46 lb)
- 200 kg (440.92 lb)
|
Minimum initial loading Emin | 0% Emax |
Maximum working load Lu | 150% Emax |
Break load Ld | 300% Emax |
Maximum lateral load Llq | 100% Emax |
Measurement characteristic values | |
Rated measuring path hn at Emax | 0.27 ± 0.05 mm (0.01 ± 0.002 in) |
Rated characteristic value Cn | 2.0 ± 0.2 mV/V |
Tolerance D0 of zero signal | < ± 1% Cn |
Maximum scale interval nlc | 3 000 |
Min. scale interval Vmin | Emax/9 000 |
Combined error Fcomb | ± 0.02% Cn |
Repeatability Fv | ± 0.017% Cn |
Creep error Fcr | |
| ± 0.02% Cn |
Temperature effect | |
| 0.017% Cn/5 K |
| 0.014% Cn/5 K |
Electrical characteristic values | |
Recommended input voltage | 5 ... 12 V DC |
Input resistance Re | 383 ? ± 6 ? |
Output resistance Ra | 351 ? ± 3 ? |
Insulation resistance Ris | 5 000 M? at 50 V DC |
Connection and ambient conditions | |
Sensor material (DIN) | Stainless steel |
Maximum tightening torque of the fixing screws | |
- Emax = 3, 5, 10, 20, 50, 100 kg (6.61, 11.02, 22.05, 44.09, 110.23, 220.46 lb)
| 14 Nm |
- Emax = 200 kg (440.92 lb)
| 16 Nm |
Rated temperature range Btn | -10 ... +40 °C (14 ... 104 °F) |
Operating temperature range Btu | -35 ... +65 °C (-31 ... +149 °F) |
Storage temperature range Bts | -40 ... +70 °C (-40 ... +158 °F) |
Degree of protection to EN 60529, IEC 60529 | IP67 |
Cable connection | |
Function | Color |
| green |
| black |
- SIG + (measured signal +)
| white |
- SIG – (measured signal -)
| red |
| blue |
| yellow |
| transparent |
Certificates and approvals | |
Accuracy class according to OIML R60 | C31) |