SITRANS FUH1010 | |
Specifications for interface detectors |
Accuracy | |
Accuracy | ± 0.05 of API No. |
Repeatability | ± 0.01 of API No. |
Specifications for volumetric and mass flowmeters |
Input | |
Flow range | ± 12 m/s (± 40 ft/s), bidirectional |
Flow sensitivity | 0.0003 m/s (0.001 ft/s), flow rate independent |
Accuracy | |
Typical accuracy | ± 0.5 to 1 % of flow |
Calibratable accuracy | ± 0.15 % … 0.3 % of flow, depending on version |
Batch repeatability | ± 0.05 % of flow, maximum |
Specifications for all SITRANS FUH1010 products |
Input | |
Pipe size | 6.4 mm ... 9.14 m (0.25”... 360”) |
Analog inputs | Current: 4 x 4 ... 20 mA |
Output | |
Standard outputs | - Current: 20 mA (1 k? at 30 V DC)
- Voltage: 10 V DC (5 k? minimum)
- Pulse rate: 5 kHz, Digital Quad.
- VT100 RS 232
|
Extended outputs | - HART, BACnet MSTP/BACnet IP, Modbus RTU & TCP/IP, Ethernet IP, Johnson N2
- 4 x 4 … 20 mA
- Form C relays
- Digital pulse
|
Status/Alarm I/O | - Programmable relays
- Totalizer clear switch input (not for IP65 (NEMA 4X) enclosure)1)
- Totalizer hold switch input
|
Accuracy | |
Zero Drift | 0.0003 m/s (0.001 ft/s), with ZeroMatic Path active (not provided for interface detector) |
Data refresh rate | 5 Hz |
Rated operation conditions | |
Degree of protection | |
| IP65 (NEMA 4X) |
- Wall mount explosionproof
| IP66 (NEMA 7) |
Liquid temperature | |
| -40 ... +120 °C (-40 ... +250 °F) |
| -40 ... +230 °C (-40 ... +450 °F) |
Ambient temperature | -18 ... +60 °C (0 ... 140 °F) |
Design | |
Dimensions | see SITRANS F US Clamp-on System info and selection guide |
Weight | see diagrams |
Power supply | |
IP65 (NEMA 4X) wall mount and IP66 (NEMA 7) wall mount explosionproof | 90 ... 240 V AC, 50 … 60 Hz, 30 VA or 9 ... 36 V DC, 12 W |
Indication and operation | |
Data logger memory | 1 MByte |
Display | |
- IP65 (NEMA 4X) and
IP66 (NEMA 7) Enclosures
| 128 x 240 pixel LCD with backlight |
Keypad | |
- IP65 (NEMA 4X) and
IP66 (NEMA 7) Enclosures
| 33 keypad buttons with tactile feedback |
Language options | English, spanish, german, italian, french |
Certicates and approvals | |
IP65 (NEMA 4X) wall mount enclosure ratings |
FM and CSA | N-I Class I, Div 2 S Class II, Div 2 I.S. Class I, II, Div 1 |
CE | EMC Directive 2014/30/EU ATEX Directive 2014/34/EU |
C-TICK | |
ATEX | - Transmitter:
Ex II (1) G [Ex ia] IIC EX II 3 (1) G Ex nC [ia] IIC T5 - Sensors:
Ex II 1 G Ex ia IIC T5
|
IP66 (NEMA 7) wall mount explosionproof enclosure ratings |
FM and CSA | XP Class I, Div 1 D-I Class II, Div 1 N-I Class I, Div 2 S Class II, Div 2 I.S. Class I, II, Div 1 |
CE | EMC Directive 2014/30/EU ATEX Directive 2014/34/EU |
C-TICK | |
ATEX | - Transmitter:
Ex II (1) G [Ex ia] IIC Ex II 3 (1) G Ex nC [ia] IIC T5 Ex II 2 (1) G Ex d [ia IIC] IIB + H2 T5 - Sensors:
Ex II 1 G Ex ia IIC T5
|