Model | Bending ring |
Rated load/maximum load Emax | 60/130/280 kg | 0.5/1/2/3.5/ 5/10 t | 13/28/60 t |
Accuracy class according to OIML R60 | C3 | C3 | C3 |
Max. load cell verification intervals nlc | 3000 | 3000 | 3000 |
Min. load cell verification intervalls Vmin | Emax./17500 | Emax./10000 | Emax./17500 |
Minimum application range Rmin(lc) | 17 % | 30 % | 17 % |
Combined error Fcomb | ? ± 0.018 % Cn | ? ± 0.023 % Cn | ? ± 0.018 % Cn |
Repeatability Fv | ? ± 0.01 % Cn | ? ± 0.01 % Cn | ? ± 0.01 % Cn |
Return of zero signal | ? ± 0.0167 % Cn1) | ? ± 0.0167 % Cn1) | ? ± 0.0167 % Cn1) |
Creep error Fcr | | | |
| ? ± 0.0120 % Cn1) | ? ± 0.0120 % Cn1) | ? ± 0.0120 % Cn1) |
| ? ± 0.0053 % Cn1) | ? ± 0.0053 % Cn1) | ? ± 0.0053 % Cn1) |
Temperature effect | | | |
| ? ± 0.004 % Cn/5K | ? ± 0.007 % Cn/5K | ? ± 0.004 % Cn/5K |
| ? ± 0.004 % Cn/5K | ? ± 0.005 % Cn/5K | ? ± 0.004 % Cn/5K |
Min. dead load Emin | ? 0 % Emax. | ? 0 % Emax. | ? 0 % Emax. |
Safe load limit Lu | 200 % Emax. | 150 % Emax. | 150 % Emax. |
Ultimate load Ld | 500 % Emax. | 300 % Emax. | 300 % Emax. |
Safe side load LIq | 75 % Emax. | 100 % Emax. | 75 % Emax. |
Rated measuring path hn at Emax. | 0.07 mm | 0.1 ± 0.02 mm | 0.11 - 0.2 mm |
Overload protection | Integrated | Integrated | Integrated for 13 t |
Supply voltage Usr (reference value) | 15 V | 10 V | 15 V |
Supply voltage (range) | 5 ... 30 V | 5 ... 30 V | 5 ... 30 V |
Rated characteristic value Cn | 1 mV/V | 2 mV/V | 2 mV/V |
Tolerance Dc of characteristic value | ± 0.01 mV/V | ± 0.1 mV/V | ± 0.1 mV/V |
Tolerance Do of zero signal | ? ± 1.0 % Cn | ? ± 1.0 % Cn | ? ± 1.0 % Cn |
Input resistance Re | 60 kg: 1260 ± 250 ? 130 kg: 1260 ± 250 ? 280 kg: 1260 ± 250 ? | 1110 ± 50 ? | 13 t: 1200 ± 100 ? 28 t: 1075 ± 100 ? 60 t: 1350 ± 100 ? |
Output resistance Ra | 1020 ± 0.5 ? | 1025 ± 25 ? | 13 t: 1000 ± 0.5 ? 28 t: 930 ± 0.5 ? 60 t: 1175 ± 0.5 ? |
Insulation resistance Ris | ? 20 M? | ? 5000 M? | ? 20 M? |
Rated temperature range Btn | -10 ... + 40 °C | -10 ... + 40 °C | -10 ... + 40 °C |
Operating temperature range Btu | -30 ... + 85 °C | -30 ... + 70 °C | -30 ... + 85 °C |
Storage temperature range Bts | -50 ... + 95 °C | -50 ... + 80 °C | -50 ... + 95 °C |
Sensor material (DIN) | Stainless steel, mat. no. 14542 | Stainless steel, mat. no. 14542 | Stainless steel, mat. no. 14542 |
Degree of protection according to EN 60529; IEC 60529 | IP66/IP68 | IP66/IP68 | IP66/IP68 |
Recommended tightening torque of the fixing screws | 8 Nm | 14 Nm (0.5 ... 5 t) | – |
Current calibration2) | Standard | Standard | Standard |
Ex protection to ATEX (optional) | II 2 G EEx ib IIC T6/T4 II 3 G EEx nA / nL IIC T6/T4 II 1D / 2D / 3D T 70 °C | II 2 G EEx ib IIC T6/T4 II 3 G EEx nA / nL IIC T6/T4 II 1D / 2D / 3D T 70 °C | II 2 G EEx ib IIC T6/T4 II 3 G EEx nA / nL IIC T6/T4 II 1D / 2D / 3D T 70 °C |
Cable connection | |
Function | Color | Color | Color |
| Pink | pink | pink |
| Gray | gray | gray |
| Brown | brown | brown |
| White | white | white |
| Transparent | Shield connected to load cell housing. Shield not led out of cable. | transparent |