Versions (mm (inch))

 

100 (4)

150 (6)

Inside pipe diameter

mm (inch)

43.1 (1.69)

76.1 (2.99)

Pipe wall thickness

mm (inch)

2.6 (0.10)

3.2 (0.13)

Mass flow measuring range at pressure drop of 2 bar (29 psi) at 1 g/cm3 (0.036 lb/inch3)

kg/h (lb/h)

203 500 (448 640)

602  000 (1 327 181)

Density

g/cm3 (lb/inch3)

0.5 … 3.5 (0.18 … 0.126)

Fraction e.g. Brix

°Brix

0 … 100 (on request)

Not possible

Temperature

  

Standard version

 

-50 … +200 °C (-58 ... +392 °F)

Ex-version

 

-50 … +200 °C (-58 … +392 °F)

Liquid pressure measuring pipe

   

Stainless steel (DIN 2413, 20 °C (68 °F))

bar (psi)

40 (580)

40 (580)

Materials

 

Measuring pipe

 

Stainless steel AISI 316Ti/1.4571 or Hastelloy C4/2.4610

Enclosure

 

IP67

Enclosure material/connection box

 

AISI 304 (1.4301)/aluminium, max. pressure 40 bar (580 psi)

Process connections

 

See dimensional drawings

Electrical connections

 

Screw terminals, M20

Cable

 

5 x 2 x 0.35 mm2 twisted and screened in pairs, ext. O 12 mm

Cable length

 

10, 25, 75 or 150 m (32.8, 82, 246 or 492 ft)

Ex-version

  

ATEX

 

II 1/2 G Ex e m d [ia] IIC T6...T2

II 2 D Ex tD A21 IP6X T115°C ... Tfluid

Weight approx.

kg (lb)

91 (201)

261 (573)



For accuracy specifications see „System information Coriolis mass flowmeters“.

Pressure drop