General technical data |
Degree of protection | IP20 according to IEC 60 529 |
Ambient temperature | |
- For horizontal installation
| 0 to 60 °C |
- For vertical installation
| 0 to 40 °C |
Relative humidity | 10 to 95%, non-condensing, corresponds to relative humidity (RH), stress level 2 acc. to IEC 61131, Part 2 |
Air pressure | From 1080 to 795 hPa (corresponds to an altitude of -1000 to +2000 m) |
Insulation | |
| 500 V DC test voltage |
| 2500 V DC test voltage |
| 4000 V DC test voltage |
Electromagnetic compatibility | Requirements of the EMC directive; interference immunity according to IEC 61000-6-2 |
- Pulse-shaped disturbance variables
| Test according to: Electrostatic discharge according to IEC 61000-4-2, burst pulses according to IEC 61000-4-4, energy single pulse (surge) according to IEC 61000-4-5, |
- Sinusoidal disturbance variables
| Test according to: HF irradiation according to IEC 61000-4-3, HF decoupling according to IEC 61000-4-6 |
- Emission of radio interference
| Interference emission according to EN 50081-2 Test according to: Emitted interference of electromagnetic fields according to EN 55016: Limit value class A, (measured at a distance of 10 m) Interference emission via AC mains according to EN 55011: Limit value class A, Group 1 |
Mechanical strength | |
| Frequency range 10 Hz ? f ? 58 Hz - Continuous: 0.0375 mm amplitude
- Occasionally 0.75 mm amplitude
Frequency range 58 Hz ? f ? 150 Hz - Continuous: 0.5 g constant acceleration
- Occasionally 1 g constant acceleration
Testing according to IEC 60068-2-6 Tested with: 5 Hz ? f ? 9 Hz, constant amplitude 3.5 mm; 9 Hz ? f ? 150 Hz, constant acceleration 1 g; Duration of oscillation: 10 frequency passes per axis in each direction of the 3 mutually perpendicular axes |
| Testing according to IEC 60068-2-27 Tested with: Half-sine wave: strength of shock 15 g peak value, 11 ms duration; Shock direction: 3 shocks each in ± direction in each of the 3 mutually vertical axes |