SIWAREX WL230 SB-S CA | |
Possible applications | Platform scales, container weighers |
Model | - Bending beam up to rated load 250 kg
- Shear beam from rated load 500 kg
|
Accuracy class OIML R60 | OIML C3 | OIML C4 | OIML C5 |
Rated load/maximum load Emax. | 100 kg, 250 kg, 500 kg, 1 000 kg, 2 000 kg, 3 000 kg 5 000 kg, 10 000 kg | 100 kg, 250 kg, 500 kg, 1 000 kg, 2 000 kg, | 3 000 kg, 5 000 kg, 10 000 kg |
Max. load cell verification interval nlc | 3 000 | 4 000 | 5 000 |
Min. Load cell verification interval Vmin | 10 000 | 15 000 | 20 000 | 18 000 |
Combined error Fcomb | ? ± 0.023 % Cn | ? ± 0.018% Cn | ? ± 0.014% Cn |
Minimum initial loading Emin | 0 kg |
Max. working load Lu | 150 % Emax. |
Break load Ld | 300 % Emax. |
Max. lateral load LIq | 100 % Emax |
Recommended supply voltage | 5 ... 12 V DC |
Maximum supply voltage | 18 V DC |
Rated characteristic value Cn | 3.0 ± 0.003 mV/V |
Tolerance Do of zero signal | ? ± 1.0 % Cn |
Creep error 30 min Fcr | ? ± 0.015 % Cn |
Input resistance Re | 350 ± 3.5 ? |
Output resistance Ra | 350 ± 3.5 ? |
Insulation resistance Ris | ? 5 000 M? at 50 V DC |
Rated temperature range Btn | -10 ... +40 °C |
Operating temperature range Btu | -35 ... +65 °C |
Storage temperature range Bts | -40 ... +80 °C |
Sensor material (DIN) | Steel, nickel-plated |
Degree of protection acc. to EN 60529 | IP67 |
Recommended tightening torque of the fixing screws | |
| |
Length of the connecting cable (four-core) | |
- For rated loads up to 2 t
- For rated loads more than 2 t
| |
Diameter of the connecting cable | 5 mm |
Color coding of the connecting cable | Color |
- EXC +
- EXC -
- SIG +
- SIG -
- Shield (not connected to the load cell body)
| - Red
- Black
- Green
- White
- Transparent
|
ATEX | - |