product brand name | | SIPLUS |
Product designation | | CIM4310 PROFINET |
General technical data: | | |
Equipment marking / acc. to DIN EN 81346-2 | | K |
Number of slots | | 1 |
Type of power output / connectable | | POM4320 |
Power supply: | | |
Type of voltage / of the supply voltage | | DC |
Supply voltage / 1 / at DC / Rated value | V | 24 |
Relative negative tolerance / of the supply voltage | % | 20 |
Relative positive tolerance / of the supply voltage | % | 20 |
Active power consumption | W | 3 |
Type of electrical connection / for supply voltage | | Connector, 2 x 2-pole |
Type of connectable conductor cross-section | | |
| | |
| | 1x (0.2 ... 2.5 mm?) |
| | 1x (0.2 ... 2.5 mm?) |
| | 26 ... 12 |
Communication: | | |
Design of the interface | | PROFINET IO |
Protocol / is supported | | |
| | - |
| | Yes |
Transfer rate | | |
| | - |
| Mbit/s | 100 |
Type of electrical connection | | |
| | - |
| | 2 x RJ45 |
Number of status displays | | 3 |
Display version / as status display by LED | | LED green = ready, LED yellow = heating on/off, LED red = error display |
Mechanical data: | | |
mounting position | | vertical |
Mounting type | | Screw mounting to POM |
Type of ventilation | | Forced ventilation |
Shock resistance | | |
| | 15g / 11 ms / 3 shocks / axis |
| | 25 g / 6 ms / 1000 shocks / axis |
Vibration resistance | | |
| | 10 ... 58 Hz / 0.075 mm, 58 ... 150 Hz / 1g |
| | 5 ... 8.5 Hz / 3.5 mm, 8.5 ... 500 Hz / 1g |
Protection class IP | | IP20 |
Width | mm | 56 |
Height | mm | 285 |
Depth | mm | 136 |
Electical data: | | |
Conducted interference / due to burst / acc. to IEC 61000-4-4 | | 2 kV power supply lines, 2 kV PROFINET cables |
Conducted interference / due to surge / acc. to IEC 61000-4-5 | | DC supply lines: 0.5 kV symmetric and unsymmetric PROFINET cables: 1 kV unsymmetric |
Conducted interference / due to high-frequency radiation / acc. to IEC 61000-4-6 | | 10 V (0.15 ... 80 MHz) |
Electrostatic discharge / acc. to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling / acc. to IEC 61000-4-3 | | 10 V/m (80 ... 1000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz) |
EMC emitted interference | | Limit value in accordance with IEC 61000-6-4:2007 + A1:2011 |
Overvoltage category | | III |
Ambient conditions: | | |
Ambient temperature | | |
| °C | 0 ... 55 |
| °C | -25 ... +70 |
| °C | -25 ... +70 |
Air pressure | | |
| hPa | 860 ... 1 080 |
| hPa | 660 ... 1 080 |
Relative humidity | | |
| % | 95 |
| % | 50 |
| | 95% at 25 °C, decreasing linearly to 50% at 50 °C |
Degree of pollution | | 2 |
Installation altitude / at height above sea level / maximum | m | 2 000 |