Cooling | Forced ventilation | Water cooling |
- Cooling water pressure at inlet, max.
| ? | 6 bar |
- Cooling water flow volume
| | |
| ? | 6 l/min (1.59 US gallons/min.) |
| ? | 8 l/min (2.11 US gallons/min.) |
| ? | 12 l/min (3.17 US gallons/min.) |
| | 15 l/min (3.96 US gallons/min.) |
| ? | 15 l/min (3.96 US gallons/min.) |
| ? | 20 l/min (5.28 US gallons/min.) |
| ? | 35 l/min (9.25 US gallons/min.) |
- Connecting thread at NDE1)
| ? | |
| ? | G 1/8“ |
| ? | G 1/4“ |
| ? | G 3/8“ |
| ? | G 1/2“ |
| ? | G 3/8“ |
| ? | G 3/8“ |
| ? | G 1/2“ |
Ambient temperature, permissible | -15 ... +40 °C (5 ... 104 °F) |
Coolant inlet temperature | ? | < 30 °C (86 °F) |
Temperature monitoring | KTY 84 temperature sensor in the stator winding |
| Additional KTY 84 as spare |
Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1) | For an ambient temperature of up to 40 °C (104 °F) Temperature class 180 (H) | For a coolant inlet temperature of up to 30 °C (86 °F) Temperature class 180 (H) |
Motor fan ratings | | ? |
- 1PH808
- 1PH810 bis 1PH816
- 1PH818/1PH822
- 1PH828
| 230 V 1 AC 50/60 Hz, 265 V 1 AC 60 Hz 400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz 200 V ... 277 V 1 AC 50/60 Hz (EC fan) 400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz | - - - - |
Encoder system, built-in | Without DRIVE-CLiQ interface or with DRIVE-CLiQ interface |
Sound pressure level LpA (1 m) in accordance with DIN EN ISO 1680 Tolerance + 3 dB | Rated pulse frequency 4 kHz | Rated pulse frequency 4 kHz/2 kHz2) |
| 70 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm | 68 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm |
| 73 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm | 69 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm |
| 73 dB at a rated pulse frequency of 2 kHz and a speed range: Forced ventilation (IP55) 1PH818 up to 5000 rpm 1PH822 up to 4500 rpm | 70 dB at a rated pulse frequency of 2 kHz or 4 kHz and a speed range: 1PH818 up to 5000 rpm 1PH822 up to 4500 rpm |
| 74 dB at a rated pulse frequency of 2 kHz and a speed range up to 3300 rpm: Forced ventilation (IP55) 1PH828 up to 3300 rpm | 72 dB at a rated pulse frequency of 2 kHz and a speed range up to 3300 rpm |
Connection | |
| Power connector or terminal box |
- 1PH816/1PH818/1PH822/1PH828
| Terminal box | Terminal box |
| | |
| Power connector | ? |
| Power connector or terminal box | ? |
- 1PH816/1PH818/1PH822/1PH828
| Terminal box | - |
| Connector for signals (without mating connector) or DRIVE-CLiQ |
Vibration severity | In accordance with Siemens/EN 60034-14 (IEC 60034-14) |
Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072-1)2) | Tolerance R |
Degree of protection in accordance with EN 60034-5 (IEC 60034-5) | | |
- 1PH808/1PH810/1PH813/1PH816
| IP55 | IP65 |
| IP55 | IP55 |
| IP55, option IP74: IP65 | ? |
Rating plate | 1 unit attached to motor 1 unit supplied loose in terminal box |
Paint finish | Anthracite RAL 7016 |
Approvals, according to | cURus |