- SINAMICS SL150 replaces the SIMOVERT D
- Thyristor?based power unit allows power ratings of up to 36 MVA
- Either an open or star connection
- 2 ? 950 6?pulse parallel connection for high power ratings with 12?pulse line harmonics
|
Air cooling *)
|
Supply voltage
|
Motor voltage
|
Power
|
|
(V)
|
(V)
|
(MVA)
|
|
Single 6?pulse connection
|
Open connection
|
1180
|
1700
|
3.2 ... 9.4
|
|
Star connection
|
3 ? 950
|
1515
|
2.9 ... 8.4
|
|
3 ? 1360
|
2190
|
6.3 ... 8.7
|
|
2 ? 6-pulse parallel connection
|
Open connection
|
2 ? 1180
|
1700
|
10.6 ... 16.9
|
|
Star connection
|
6 ? 950
|
1515
|
9.4 ... 15.1
|
|
6 ? 1360
|
2190
|
11.4 ... 15.7
|
|
12?pulse parallel connection
|
Open connection
|
2 ? 1180
|
2 ? 1700
|
11.8 ... 18.8
|
|
Star connection
|
6 ? 950
|
2 ? 1515
|
10.5 ... 16.8
|
|
6 ? 1360
|
2 ? 2190
|
12.5 ... 17.4
|
*) Air-cooled, capable of a 200 % overload for up to 60 sec.
|
Water cooling **)
|
Supply voltage
|
Motor voltage
|
Power
|
|
(V)
|
(V)
|
(MVA)
|
|
12?pulse series connection
|
Star connection
|
2 ? 1310
|
4000
|
12 ... 18
|
|
2 ? 6?pulse parallel connection
|
Star connection
|
2 ? 2620
|
2 ? 4000
|
24 ... 36
|
**) Water?cooled, capable of a 150 % overload for up to 60 sec.
|
|