Type
|
|
6FE1086-0SY00-0AA0
|
6FE1086-0SY00-1AA0
|
6FE1086-3SY00-0AA0
|
|
Product brand name
|
|
SIPLUS ECC8000
|
|
Product description
|
|
SYS-101A
|
SYS-102A
|
SYS-202A
|
|
General data
|
|
|
|
Product description
|
|
Preassembled functional unit for installation in wall box in domestic environment (e.g. garage)
|
Preassembled functional unit for installation in simple charging pole
|
Preassembled functional unit for installation in public/semi-public charging poles
|
|
Suitability for use
|
|
Function unit for charging stations at home (home charging)
|
Functional unit for wall boxes or simple charging posts
|
Functional unit for professional charging posts in the public area
|
|
Product component
Charging outlets
|
|
yes
|
|
Number of charging outlets
|
|
1
|
2
|
|
Number of interfaces
according to IEC 61851
|
|
1
|
2
|
|
Charging current
|
A
|
16 --
|
13 / 32 (automatic switchover)
|
32 -- each
|
|
Product function
|
|
|
|
|
|
No
|
yes
|
|
|
|
no
|
yes
|
|
|
|
--
|
24 V / 12 V (motorized)
|
|
|
|
no
|
yes
|
|
Number of energy measurement points
|
|
0
|
1
|
2
|
|
Standard
for electric vehicle charging mode
|
|
IEC / ISO 61851
|
|
Degree of pollution
|
|
2 (cabinet requirement)
|
|
Type of the sensor
|
|
--
|
Humidity/temperature
|
|
IP degree of protection
|
|
IP00
|
|
Overvoltage category
|
|
2
|
|
RCCB type
|
|
Type A
|
|
Installation altitude
at height above sea level
maximum
|
m
|
1 000
|
|
Ambient temperature
|
|
|
|
|
°C
|
-40 … +75
|
-20 … +60
|
|
|
°C
|
-20 … +45
|
-5 … +45
|
|
|
°C
|
-40 … +75
|
-20 … +60
|
|
Relative humidity
during operation
maximum
|
%
|
95
|
|
Product component
Heating
|
|
no
|
yes
|
|
Product function
Overvoltage protection
|
|
no
|
|
Inputs
|
|
|
|
Type of voltage
of supply voltage
|
|
AC
|
|
Operating voltage
with AC
Rated value
|
V
|
400
|
|
Input voltage
|
V
|
360 … 440
|
|
Line frequency
1
Rated value
|
Hz
|
50
|
|
Insulation voltage
Rated value
|
V
|
440
|
|
Suitability for use
for line system configuration
|
|
TNS
|
|
Current
with AC
Rated value
|
A
|
18
|
35
|
72
|
|
Outputs
|
|
|
|
Number of phases
of outputs
|
|
3
|
|
Communications
|
|
|
|
Product function
Bus communication
|
|
no
|
yes
|
|
Type of data transmission
to control system
|
|
--
|
Ethernet
|
|
Protocol
supported
|
|
|
- Vehicle communication according to IEC 61851
|
|
yes
|
|
|
|
no
|
yes
|
|
Conducted interference BURST
according to IEC 61000-4-4
|
|
2 kV / 5 kHz AC supply lines and functional grounding, 1 kV / 5 kHz control lines and input/output signals
|
|
Conducted interference SURGE
according to IEC 61000-4-5
|
|
Asymmetrical: Supply lines 2 kV, signal lines >30 m 1 kV, evaluation criterion B. Symmetrical: Supply lines 1 kV, evaluation criterion B
|
|
Field-based interference
according to IEC 61000-4-3
|
|
80 MHz ... 1 GHz 3 V/m, 1.4 ... 2 GHz 3 V/m, evaluation criterion A; 80 MHz ... 1 GHz 10 V/m evaluation criterion B; 2.0 ... 2.7 GHz 1 V/m
|
|
Electrostatic discharging
according to IEC 61000-4-2
|
|
4 kV contact discharging / 8 kV air discharging, evaluation criterion B
|
|
Conducted interference as high frequency radiation
according to IEC 61000-4-6
|
|
3 V effective in frequency range 0.15 ... 80 MHz, evaluation criterion A
|
|
Immunity to magnetic fields with energy frequencies
in accordance with EN 61000-4-8
|
|
100 A/m at 50 Hz and 60 Hz, evaluation criterion A
|
|
EMC interference emission
according to IEC 61000-6-3
|
|
suitable for use in residential areas, public areas and industry
|
|
Shock resistance
|
|
|
- according to IEC 60068-2-27
|
|
15 g / 11 ms / 3 shocks / axis
|
- during transport according to IEC 60068-2-29
|
|
1000 shocks / axis, 25 g, 6 ms
|
|
Vibration resistance
|
|
|
- during transport according to IEC 60068-2-6
|
|
5 ... 500 Hz / 1 g / 10 cycles
|
- during operation according to IEC 60068-2-6
|
|
5 ... 150 Hz / 1 g / 10 cycles
|
|
Mechanical specifications
|
|
|
|
Installation position
|
|
Vertical
|
|
Type of mounting
|
|
Screw mounting
|
|
Dimensions
|
|
|
|
|
mm
|
370
|
900
|
|
|
mm
|
230
|
240
|
|
|
mm
|
150
|
200
|
270
|